Group: Yokogawa
Catalog excerpts
Multi Application Test System Multi Application Test System Ideal Measurement Solution for Optical Devices and Optical Transmission Systems ■ A broad lineup of measurement modules Grid tunable laser source, Optical power meter, Optical attenuator, Optical switch, etc. ■ Macro programming Function Convenient solution for automated measurements eliminating need for an external PC controller. ■ Remote interfaces : GP-IB, Ethernet, and
Open the catalog to page 1Ideal Measurement Solution for Optical Devices and Optical Transmission Systems The AQ2200 Multi Application Test System is the ideal system for measuring and evaluating a wide range of optical devices and optical transmission systems. A variety of measurement modules are available, including the following: grid tunable laser source, high-speed optical sensors, high-resolution and high-speed variable optical attenuators and optical transceiver interfaces. These modules can be installed in any combination on a single platform, providing an ideal measurement system for a variety of...
Open the catalog to page 2Mufti Application Test System Automated Testing Macro Programming function A macro program function makes it easy to build a simple automated measurement system by writing a series of operations in a program, setting measurement conditions, changing test configurations in combination with multiple modules, executing measurements, and saving results. Step 1: Create a macro program using Macro editor, a Step 2: Install the macro program into Frame controller via GP-IB, Ethernet, or USB. Step 3: Execute the macro program on the frame Macro editor. Macro editor Install MACRO to Frame...
Open the catalog to page 3Module Lineup Optical Power Meter Improved measurement throughput High-Power (AQ2200-215) • igh power measurement: +30 dBm H • ower range: -70 to +30 dBm P • veraging time: 100 µs (minimum sampling intervals) A • ompact: Two high-performance sensors in a module. C • ower range: -70 to +10 dBm P • Averaging time : 200 µs (minimum sampling intervals) Light Source Grid Tunable Laser Source (AQ2200-131/-132) • Frequency (Wavelength) range: C/L-band • 1 and 2 channel modules • Grid spacing: Standard type: in. 50 GHz (0.4 nm) m Advanced type: in. 25 GHz (0.2 nm) and manual (0.1 GHz) m • Dither...
Open the catalog to page 4Measurement Applications 3-wavelength Optical Filter Measurement System for GE-PON Optical Fiber Amplifier Measurement System A 3-wavelength optical filter for GE-PON splits 1490 nm and 1550 nm optical signals, and pass a 1310 nm optical signal in the return direction. This measurement system measures the insertion losses of wavelengths passing between ports and the isolation of wavelengths blocked. [Measurement items] • nsertion loss: (1) to (2) 1490 nm, (1) to (3) 1550 nm, (2) to (1) 1310 nm I • solation: (1) to (2) 1550 nm, (1) to (3) 1490 nm, (2) to (3) 1310 nm I Light source Light...
Open the catalog to page 5Product Specifications Frame Controller (AQ2211/2212) Items Product name Number of slots Display GPIB Ethernet USB External storage interface Interlock connector Preset applications Functions Control functions Ambient temperature Operation environment Ambient humidity Ambient temperature Storage environment Ambient humidity Power requirement Power Consumption (including modules) Dimension (excluding protrusions) Mass Recommended calibration period Remote interface Color LCD, 320 × 240 dot IEEE-488 compatible, protocol: IEEE-488.2 compatible IEEE802.3 compatible, connector: RJ-45 × 1,...
Open the catalog to page 6DUAL ATTN Module(AQ2200-342) Items Number of channels Wavelength range Insertion loss Maximum attenuation Power setting range Setting resolution Attenuation accuracy Repeatability Output monitor accuracy Optical return loss Polarization dependence Maximum input power Shutter isolation Settling time Applicable optical fiber Optical connector Product Specs 2 1260 to 1640 nm 1.8 dB (typ.) 40 dB −50 to +20 dBm 0.01 dB ±0.15 dB (typ.) (attenuation 0 to 10 dB), ±0.20 dB (typ.) (attenuation 10 to 20 dB), ±0.45 dB (typ.) (attenuation 20 to 40 dB) ±0.10 dB (typ.) (attenuation 0 to 20 dB), ±0.15 dB...
Open the catalog to page 7Ordering Information AQ2211 Frame Controller Model 735101 UL / CSA standard VDE standard AS standard BS standard GB standard AQ2212 Frame Controller Model 735102 Optical fiber: SMF Optical connector: FC/PC Optical connector: FC/Angled PC Port confi guration: 1 × 4 Port confi guration: 1 × 8 Optical fiber: SMF Optical fiber: MMF (GI 50/125) Optical fiber: MMF (GI 62.5/125) Optical connector: FC / PC Optical connector: SC / PC Port confi guration: 1 × 16 Optical fiber: SMF Optical fiber: MMF (GI 50/125) Optical connector: FC / PC Optical connector: SC / PC Port confi guration: Dual 1 × 2 Port...
Open the catalog to page 8All YOKOGAWA Europe catalogs and technical brochures
-
YS1500
20 Pages
-
UM33A/S006
2 Pages
-
YTA610
20 Pages
-
FA-M3V
19 Pages
-
RAMC
24 Pages
-
GS610 Source Measure Unit
12 Pages
-
EJXC40A Digital Remote Sensor
135 Pages
-
TB750G EXAxt
3 Pages
-
VPSRemote Remote Solution
2 Pages
-
SENCOM Degital Sensor
3 Pages
-
Product Solution Catalog
8 Pages
-
Data Logging Software GA10
4 Pages
-
JUXTA VJ series
7 Pages
-
µR10000/µR20000
8 Pages
-
OX400
2 Pages
-
PR300 Power and Energy Meter
4 Pages
-
CENTUM RIO System Upgrade
4 Pages
-
Autonomous Controller FCN-RTU
17 Pages
-
MW100
5 Pages
-
FieldMate
5 Pages
-
AMADAS
4 Pages
-
Exapilot
5 Pages
-
Exaquantum
5 Pages
-
BUCA150_E_050
4 Pages
-
BUAQ7280-01
12 Pages
-
BUXL120_E_030
8 Pages
-
BU7603_00E_060
20 Pages
-
NR800 Near Infrared Analyzer
8 Pages
-
GD402 Gas Density Analyzer
3 Pages
-
DT450G Dust Monitor
3 Pages
-
SCADA Software VDS
7 Pages
-
Batch Control
9 Pages
-
FieldMate catalogs
5 Pages
-
DPharp for The Digital World
9 Pages
-
RAGN Rotameter
2 Pages
-
HART Communicator YHC5150X
2 Pages
-
Catalog_YMI130_EN
86 Pages
-
Bulletin11G04G01-01E
3 Pages
-
Bulletin11B03A03-01E
10 Pages
-
FY01A08A08-E-E
2 Pages
-
Ultrasonic Flowmeter US300FM
2 Pages
-
AXF Verification Tool
2 Pages
-
ADMAG Series
9 Pages
-
Exaplog
2 Pages
-
AAASuite
2 Pages
-
InfoWell
8 Pages
-
Low Power Controller FCN-RTU
3 Pages
-
Standalone SIS
3 Pages
-
VTSPortal
2 Pages
-
CENTUM VP - CAMS for HIS
4 Pages
-
GS01E06K02-00E
2 Pages
-
U33Q01A01-01E
11 Pages
-
BU33K01A01-50E
11 Pages
-
Thermometers Catalog
8 Pages
-
PH400G 4-Wire Type pH Meter
27 Pages
-
SG750 Stack Gas Analyzers
26 Pages
-
Clamp-on Testers
12 Pages
-
Dust Monitor DT450G
3 Pages
-
Handy Calibrators
4 Pages
-
CENTUM.VP
11 Pages
-
Fieldbus Segment Indicator
5 Pages
-
ADMAG AXF
2 Pages
-
YTA series
7 Pages
-
TEST & mEASUREmENT 2011
28 Pages
-
digital multimeter series
12 Pages
-
WT 3000 Precision Power Analyzer
19 Pages
-
DL850/DL850V SCOPECORDER
14 Pages