COMPANY COMPANY It all began in 2004, when our engineering team had to find a solution to a particular plant application and came up with a unique solution: a spring-less check valve. This led to the development of a patent covering a technology able to offer an essential, maintenance-free one-way valve, thanks to the total absence of traditional intermediate components. The company developed under the name of Carollo srl, an engineering company with over 40 years of experience in the food, chemical and pharmaceutical sectors. After the success of the first prototypes, the project was...

Open the catalog to page 3
YGROS_VALVES - 4

The advantages of choosing our Valves NO BREAKAGE NO MAINTENANCE NO PRESSURE LOSS NO CORROSION NO FLOW OBSTRUCTION NO STAGNATION POINTS

Open the catalog to page 4
YGROS_VALVES - 5

The innovative patented magnetic Technology

Open the catalog to page 5
YGROS_VALVES - 6

OUR VALVES EDF EDF - 3A YEV YSV PHARMABALL AGGROBALL WAFER

Open the catalog to page 6
YGROS_VALVES - 7

* Self-draining eccentric version available on request. Suitable for horizontal installation. EDF: Maximum hygiene with no maintenance required. Tightness guaranteed in all installation positions, even vertical with downward flow. The patented YGROS technology sets new standards in the plant engineering world, thanks to its magnetic principle that replaces the function of the traditional spring. uitable for S fluids and steam. Resistant up to 220°C. No more springs that can break or misfire No flow obstruction components No stagnation points Applications Pharmaceutical Chemical Cosmetic...

Open the catalog to page 7
YGROS_VALVES - 8

YGROS MAGNETIC PRINCIPLE The main operational difference between a spring loaded check valve and the innovative YGROS valve is the resistance to flow. An ordinary check valve in the open position imposes significant resistance, because the compressed spring pushes the shutter against the flow with considerable force. The magnets built into the valve body keeps the shutter in a closed position. Ygros check valve opens when the inflow pressure exceeds the magnetic force. In the open position the shutter moves away from the magnet, which means lower attraction to the seat and therefore lower...

Open the catalog to page 8
YGROS_VALVES - 9

Once opened, the required pressure to keep the shutter fully open is about 10 mbar. FLOW DIRECTION OPENING PRESSURE HORIZONTAL lines VERTICAL lines VERTICAL lines PRESSURE DROP CHART Graph reading applies to water at 20° C (68°F) installed in horizontal pipes Customizable materials, finishings and further configurations available on request

Open the catalog to page 9
YGROS_VALVES - 10

EDF 3-A EDF 3A: Specially designed for the US market and officially approved by the 3-A Institute. Maximum hygiene with no maintenance required. Tightness guaranteed in all installation positions, even vertical with downward flow. Suitable for fluids and steam. Resistant up to 220°C. No more springs that can break or misfire No flow obstruction components No stagnation points Applications Pharmaceutical Chemical Cosmetic Food& Beverage BENEFITS AT A GLANCE Maximum hygiene: Only the shutter comes into contact with the product. There are no springs, discs or other components which could...

Open the catalog to page 10
YGROS_VALVES - 11

YGROS MAGNETIC PRINCIPLE The main operational difference between a spring loaded check valve and the innovative YGROS valve is the resistance to flow. An ordinary check valve in the open position imposes significant resistance, because the compressed spring pushes the shutter against the flow with considerable force. The magnets built into the valve body keeps the shutter in a closed position. Ygros check valve opens when the inflow pressure exceeds the magnetic force. In the open position the shutter moves away from the magnet, which means lower attraction to the seat and therefore lower...

Open the catalog to page 11
YGROS_VALVES - 12

Once opened, the required pressure to keep the shutter fully open is about 10 mbar. FLOW DIRECTION OPENING PRESSURE HORIZONTAL lines VERTICAL lines VERTICAL lines PRESSURE DROP CHART Graph reading applies to water at 20° C (68°F) installed in horizontal pipes Customizable materials, finishings and further configurations available on request

Open the catalog to page 12
YGROS_VALVES - 13

YEV: the simplest patented non-return valve in the entire Ygros range, but it does not lose its hygienic and reliable characteristics. A smart solution for all hygenic applications. Resistant up to 220°C. No more springs that can break or misfire No flow obstruction components No stagnation points Applications Food & Beverage BENEFITS AT A GLANCE Maximum hygiene: Only the shutter comes into contact with the product. There are no springs, discs or other components which could contaminate it. Safe closing: ensured by patented magnetic principle Any installation position possible: it can be...

Open the catalog to page 13
YGROS_VALVES - 14

Maintenance: Free Longer valve life: Thanks to high chemical resistance of the materials YGROS MAGNETIC PRINCIPLE The main operational difference between a spring loaded check valve and the innovative YGROS valve is the resistance to flow. An ordinary check valve in the open position imposes significant resistance, because the compressed spring pushes the shutter against the flow with considerable force. The magnets built into the valve body keeps the shutter in a closed position. Ygros check valve opens when the inflow pressure exceeds the magnetic force. In the open position the shutter...

Open the catalog to page 14
YGROS_VALVES - 15

Once opened, the required pressure to keep the shutter fully open is about 10 mbar. FLOW DIRECTION OPENING PRESSURE HORIZONTAL lines VERTICAL lines VERTICAL lines PRESSURE DROP CHART Graph reading applies to water at 20° C (68°F) installed in horizontal pipes Customizable materials, finishings and further configurations available on request

Open the catalog to page 15
YGROS_VALVES - 16

YSV YSV: The extractable valve. Thanks to its specially developed design, it is the suitable solution for plants which require periodic maintenance. Resistant up to 150°C. No more springs that can break or misfire No flow obstruction components No stagnation points Applications Dairy Cosmetics Food & Beverage BENEFITS AT A GLANCE Maximum hygiene: Only the shutter comes into contact with the product. There are no springs, discs or other components which could contaminate it, this means no contamination and no stagnation point Safe closing: ensured by patented magnetic principle Any...