Catalog excerpts
Compact V/f Control Drive 200 V CLASS, THREE-PHASE INPUT: 0.1 to 5.5 kW 200 V CLASS, SINGLE-PHASE INPUT: 0.1 to 2.2 kW 400 V CLASS, THREE-PHASE INPUT: 0.2 to 5.5 kW
Open the catalog to page 1Compact V/f Control Drive
Open the catalog to page 2Reliability the world has come to expect from Yaskawa as a global leader is now packed into an even smaller, more powerful unit. So easy to use: just switch it on and J1000 is fully capable of efficient performance and energy saving, handling variable speed needs in compact applications. A drive that exemplifies true world quality with a difference you can really 20 Standard Connection Diagram 24 Drive Watts Loss Data 26 Peripheral Devices and Options 51 YASKAWA AC Drive Series 53 Global Service Network
Open the catalog to page 3Fully Equipped with User and Environmentally-Friendly Functions Compact Design Every drive has dual rating, Normal Duty (ND) and Heavy Duty (HD). Parameter settings let the user select the rating that best suits the application needs. Selecting ND allows the drive to operate a more powerful motor an entire frame size larger than with HD. Side-by-Side installation and JIOOO's impressively compact design make it possible to fit the entire setup into even the narrowest enclosures. Note: Current derating must be considered. Select a motor that has a current rating within the rated current of...
Open the catalog to page 4Compact V/f Control Drive 2. Ensuring Stable Operation Starts Heavy Loads Effortlessly_ Fully automatic torque compensation across the entire speed range, whether accelerating, decelerating, or operating at constant speed. Capable of 100% rated torque as low as 1.5 Hz, and 150% at 3 Hz when set for Heavy Duty performance. • Powerful Torque Enhanced Braking The overexcitation braking functions enables rapid braking up to 50% faster without using a braking resis- tor. All models come equipped with a braking transistor for even faster stopping capabilities should the user decide to install a...
Open the catalog to page 5True Reliability and Top Quality Assurance Hassle-Free Maintenance Yaskawa drives have a built-in maintenance timer that keeps track of component performance, including capacitors, soft- charge circuitry, IGBTs, and the cooling fan. This ensures maximum performance life of the drive. The cooling fan is also designed for quick replacement: both detachable and easily accessible from the top of the drive. Engineering tool DriveWizard Plus automatically converts parameter settings from the earlier VS mini J7 to match Not only useful for model upgrades and transitions, but also a time-saving...
Open the catalog to page 6Compact V/f Control Drive Wide Range of Options Available Potentiometer Option Unit (option) A speed potentiometer lets the user adjust the frequency simply by turning a dial. This optional potentiometer offers an easy way to control motor speed on the fly, without needing to access parameter settings. DriveWizard Plus (Potentiometer Option Unit The LED operator allows the user to control the drive from up to 3 meters away, saving the hassle of directly accessing the drive when mounted inside an enclosure panel. *1: Requires an optional interface unit. • View, edit, and set parameters •...
Open the catalog to page 7Fluid Applications The Setup Mode saves valuable installation time by providing just the essential parameters needed to get the application running immediately. Normal Duty keeps the cost of the application down by allowing the use of a larger motor. Speed Search prevents loss from down time by keeping the application running smoothly through a power loss. Prohibit reverse rotation with a single parameter setting to prevent improper operation and possible machine damage. Swing PWM minimizes noise and leakage current, quieting undesirable motor noise. Self-diagnostic features check the drive...
Open the catalog to page 8Conveyor, Transport, and Civil Applications The Setup Mode saves valuable installation time by providing just the essential parameters needed to get the application running immediately. Heavy Duty provides high overload capability for reliable operation without production loss from down time. Overexcitation provides increased braking torque without the need for a braking resistor, keeping the installation compact and the cost low. If even more braking torque is needed, an additional braking resistor can be connected to the built-in braking transistor. Swing PWM minimizes noise and leakage...
Open the catalog to page 9Software Functions Loaded with software functions just right for your application. Note: Major functions listed below. Easy access to the minimum- required parameters during setup. Save valuable time during setup by calling up just the parameters needed. Protect parameter settings. Once setup is complete, protect parameter settings with a password from unauthorized Dual ratings to fit a wide range of application needs. Select between Normal Duty and Heavy Duty for optimized torque performance. Functions at Start and Stop Perfect for applications with high load inertia that rarely need to be...
Open the catalog to page 10motor characteristics. Select the V/f pattern freely to gain optimal motor torque with any load condition. Easily change the direction of motor Change the direction of motor rotation more easily with parameter settings rather than reversing output phase cables to the motor. A time saver when wiring has accidentally been reversed. Prohibit reverse rotation. This function keeps the application from rotating in reverse and prevents machine damage, even if a reverse command is accidentally entered. Suppress noise and reduce motor Creates a more pleasant work environment while suppressing noise...
Open the catalog to page 11Parameter List Refer to J1000 Installation & Start-Up Manual for details.
Open the catalog to page 12#1: Values shown here are for 200 V class drives. Double the value when using a *5: Value in brackets indicates default when 3-wire initialization is performed *2: Default setting value is dependent on parameter o2-04, Drive Model Selection. *6: Default setting value is 120% when C6-01 is set to 1 (ND) and 150% *3: Default setting value is dependent on parameter C6-02, Carrier Frequency Selection. wnen C6-01 is set to 0 (HD). #4: 0.0 to 130.00 for drives less than 0.2 kW. *7: This value is not reset when the drive is initialized with parameter A1-03. -|
Open the catalog to page 13Archived catalogs
-
YASKAWA ELECTRIC CORPORATION
10 Pages
-
YASKAWA Report 2012
51 Pages
-
YASKAWA Report 2013
51 Pages
-
YASKAWA Report 2014
55 Pages
-
P1000 Catalog
52 Pages
-
MPiec Machine Controllers
8 Pages
-
YASKAWA HERMETICALLY SEALED CONTACT
110 Pages
-
AC SERVO DRIVES JUNMA SERIES
43 Pages
-
MACHINE CONTROLLER MP2000 SERIES
96 Pages
-
AC SERVO DRIVES
479 Pages
-
YASKAWA AC DRIVES
25 Pages
-
Machine Controller MP920
50 Pages
-
MACHINE CONTROLLER MP2000 SERIES
64 Pages