INSTRUMENTATION INTEGRATED SYSTEM
Open the catalog to page 1Yaskawa lets you built the optimal plant control system through open engineering as we step to the next level of technology. YEIIS1000 is a system controller designed compliant with international standards IEC61131 -3, designed with improved speed and reliability. It is an El-integrated system capable of an array of arithmetic functions and optimized control. With the superior monitoring capabilities, operability. functions for the wide range of user needs, and the flexibility to match the application. I System Specifications
Open the catalog to page 2Contact Sensor Indicator Solenoid Input Lamp System Controller High-speed N : N real-time network handling both cyclic and message transfers. A shared-memory N : N high-speed real-time network handling both cyclic and message transfers. Used primarily to interconnect controllers, HMI or EWS. Uses Ethernet protocol, primarily for connection with computers. Supports MEMOBUS, no-protocol, and MELSEC* protocol connections. Provides functions for plant operation and observation. High-speed large-capacity El-integrated controller in compliance with I EC standards. Allows the use of 5 IEC61131...
Open the catalog to page 3EC-compliant system controller integrating electrical The system controller CP-F3000 offers improved performance, functions, and reliability in addition to the functions available with earlier models. Also, the CP-F3000 features significantly enhanced functions for use with open field networks. High Speed and High Capacity Fast CPU and Large Memory Capacity The CP-F3000 can serve as the host controller in a medium- or large-scale plant. With a 32-bit, high-speed processor, the arithmetic processing speed is nearly doubled compared to earlier models. This makes it possible to meet the...
Open the catalog to page 4Can select a configuration with single, multiple, or dual CPUs to construct the optimum system for your plant Communication and I/O interface modules Multiple CPUs Communication and I/O interface modules Communication and I/O interface modules Note:Use CPUs of the same version on a single rack.CPUs of different versions can be used for different racks in the same system Open Field Network Support Supports Five Programming Languages The CP-F3000 is IEC61131 compliant system controller. It supports five programming languages that comply with IEC61131-3. Software can be improved because it is...
Open the catalog to page 5Engineering workstation supporting the maintenance of application software programming languages. Allows use of the following programming languages: Function Block Diagram (FBD) Sequential Function Chart (SFC) Using the YENS Instrument Library (FBD) Growing with the YENS Instrument Library Users can take advantage of an instrument library that has the same functions as the reputable YENS computations. Instrument Table
Open the catalog to page 6More Effective Programming Users can select the programming appropriate for their application. The example shows examples using the YEIIS1000 Instrument Library indicators * : FFLD, fixed format ladder diagram Ladder logic that incorporates control statements such as an IF statement. A program is constructed of worksheet cells divided into rows and columns. Better Operability Select then drag and drop the The intuitive user-interface makes Better Observability The structure type is used for the member variables of each device, making it easy to select parameters. /lember variables use the...
Open the catalog to page 7El-Integrated Operator Station ElC-lntegrated Plant Operator Station The Control Pack CP-5800 is a monitoring system for large-scale plant, and provides ElC-integrated environment on Microsoft Windows platform. Human Machine Interface Instrumentation functions, standard functions, electric standard function, and engineering function are loaded on a factory automated PC running Windows. This allows the user to create a monitoring control system that uses a wide area network. Standard electrical functions System monitoring functions that include fault monitoring, guidance functions, and...
Open the catalog to page 8Instrument Support Functions Maintenance and engineering support is provided by the tag list (instrument tag definitions), monitoring of member variables (instrument tags defined in the tag list), and tag data setting functions (setting changes). This defines the instrument Tag list setting screen (instrument tags) l^||L)A*t*l >Ml Inlllnl I IT I tfttfi UV.Iar I BI Opens the tag data setting screen User can change settings parameters online. Tag data setting screen (for instrument parameters) Instrument data can be sent individually to system controller CP-F3000. It's also possible to send a...
Open the catalog to page 9TOKYO OFFICE New Pier Takeshiba South Tower, 1-16-1, Kaigan, Minatoku, Tokyo 105-6891 Japan 2121 Norman Drive South, Waukegan, IL 60085, U.S.A. YASKAWA ELETRICO DO BRASIL LTDA. Avenida Fagundes Filho, 620 Sao Paulo-SP CEP 04304-000, Brazil YASKAWA ELECTRIC KOREA CORPORATION 9F, Kyobo Securities Bldg., 26-4, Yeouido-dong, Yeongdeungpo-gu, Seoul 150-737, Korea YASKAWA ELECTRIC (SINGAPORE) PTE. LTD. 151 Lorong Chuan, #04-01, New Tech Park 556741, Singapore YASKAWA ELECTRIC (SHANGHAI) CO., LTD. 12F, Carlton Bldg., No.21 HuangHe Road, HuangPu District, Shanghai 200003, China YATEC ENGINEERING...
Open the catalog to page 10Archived catalogs
-
YASKAWA ELECTRIC CORPORATION
10 Pages
-
YASKAWA Report 2012
51 Pages
-
YASKAWA Report 2013
51 Pages
-
YASKAWA Report 2014
55 Pages
-
P1000 Catalog
52 Pages
-
MPiec Machine Controllers
8 Pages
-
YASKAWA HERMETICALLY SEALED CONTACT
110 Pages
-
AC SERVO DRIVES JUNMA SERIES
43 Pages
-
MACHINE CONTROLLER MP2000 SERIES
96 Pages
-
AC SERVO DRIVES
479 Pages
-
YASKAWA AC DRIVES
25 Pages
-
Machine Controller MP920
50 Pages
-
MACHINE CONTROLLER MP2000 SERIES
64 Pages