Yaskawa Type 3R Package
6Pages

{{requestButtons}}

Catalog excerpts

Yaskawa Type 3R Package - 2

The Type 3R Package is specifically designed for Yaskawa • Dual ground lug - one lug for earth ground, one lug for Variable Frequency Drives. utility ground. The Type 3R outdoor duty package is not just a "NEMA 3R" self-declared rating. Yaskawa went beyond its own stringent testing by asking Underwriters Laboratories Inc. (UL) to test and certify this package to meet UL 508A Type 3R for outdoor use to provide a degree of protection against falling rain; undamaged by the formation of ice on the enclosure. The Type 3R Package is designed for applications such as Cooling Towers, Rooftop AHUs...

Open the catalog to page 2
Yaskawa Type 3R Package - 3

• Protecting the cabinet cooling fans in an outdoor duty enclosure is top priority. A screen is provided to go between the fan bracket and the enclosure bottom to prevent small items from damaging the filter media or blocking fan operation. • The Type 3R Package is designed to operate in a 14οF (-10οC) to 104οF (40οC) ambient temperature range. A standard option is available for 14οF (-10οC) to 122οF (50οC) ambient temperature range. This Type 3R Package is designed to operate at either temperature range without air conditioning due to the thermostatically controlled cabinet cooling fans...

Open the catalog to page 3
Yaskawa Type 3R Package - 4

• Bottom conduit entry is available without predetermined knockouts, to provide an added degree of protection from the weather elements for input power wiring, motor wiring, and control circuits. This configuration provides flexible installation options for the electrician. Circled area is the recommended conduit entrance area. • A standard part of the Type 3R Package are the integral lifting tabs provided on the side of enclosure to facilitate the physical installation without blocking access to the mounting holes. The bottom mounting holes are slotted to "rest" the Type 3R Package on the...

Open the catalog to page 4
Yaskawa Type 3R Package - 5

When vertical surfaces are limited, optional leg kits are available for the Type 3R Package to become a freestanding installation. An optional 12" Leg Kit or 30" Leg Kit is available as shown below. The following are Type 3R package options: • Service Entrance Rated Disconnect. • Space Heater with Thermostat - maintains the internal cabinet temperature to reduce condensation. • NEC branch circuit protection device for input power with flange-mounted operating handle. • Surge Suppressor - adds a degree of protection to the Type 3R Package from transient surges coming through the power line...

Open the catalog to page 5
Yaskawa Type 3R Package - 6

Mechanical Drawings (Downloadable from website) H DD.AFD.198.01 H DD.AFD.199.01 H DD.AFD.200.01 H DD.AFD.189.01 | DD.AFD.190.01 Yaskawa Electric America, Inc. 2121 Norman Drive South Waukegan, IL 60085 800-YASKAWA (927-5292) Fax: 847-887-7310 DrivesHelpDesk@yaskawa.com www.yaskawa.com

Open the catalog to page 6

All Yaskawa America catalogs and technical brochures

  1. R1000

    11 Pages

  2. FP605

    15 Pages

  3. iQrise

    2 Pages

  4. HV600

    19 Pages

  5. D1000

    2 Pages

  6. GA500

    9 Pages

  7. Sigma SD

    60 Pages

  8. GA800

    2 Pages

  9. L1000A

    2 Pages

  10. Deming Award

    2 Pages

  11. Z1000 Bypass

    2 Pages

  12. MP3200iec

    2 Pages

  13. P1000 Catalog

    52 Pages

  14. SGMMV

    20 Pages

  15. Bestact

    64 Pages

  16. A1000 Catalog

    58 Pages

  17. YASNAC 3000G

    203 Pages

  18. YASNAG 2000G

    58 Pages

Archived catalogs