R1000 - 2

R1000 REGENERATIVE BRAKING UNIT A Smart and Efficient Alternative to Dynamic Braking Unlike dynamic braking, which dissipates all braking energy in the form of heat, the R1000 avoids wasted energy by delivering it back to your power source for use by other loads. Since the R1000 transfers power during regeneration (not motoring), it is very economical for regenerative applications. Also, return on investment is often less than one year. Not only does this save energy and money, it also eliminates the need to safely locate and maintain braking resistors. COMPATIBILITY Compatible with all...

Open the catalog to page 2
R1000 - 3

SELECTION PROCESS STEP 1 SIZING EXAMPLE Regenerative duty cycle is based on the time the motor is in regeneration compared to the total cycle time. The “on time” is only when the motor is in regeneration. The “off time” can be when the motor is moving the load (motoring at steady state or accelerating) or in an idle state (powered off or stopped). This selection process assumes a one-to-one configuration. The following 40 HP centrifuge application has a very long deceleration time. The R1000 enables users to shorten deceleration time to increase production, while also saving the extra...

Open the catalog to page 3
R1000 - 4

Standard ratings are provided in two tables based on input voltage (208-240V and 480V). Current ratings are provided in three tables based on voltage (208, 240V and 480V). 208 - 240V, 3-Phase, Standard Rating Selection Table 208V, 3-Phase, Continuous Rating Selection Table Motor Power Current Suppression Reactor Power Coordination Reactor Fuse Holder(s) Part Number Part Number Part Number Part Number *1. NEMA Type 1 / IP20 Enclosure 480V, 3-Phase, Standard Rating Selection Table Power Coordination Reactor Fuse Holder(s) Part Number Part Number Part Number Part Number Current Suppression...

Open the catalog to page 4
R1000 - 5

EXTERNAL HEATSINK KITS EXTERNAL HEATSINK KITS SELECTION TABLES The optional, NEMA Type 1, heatsink kit allows the R1000 to be mounted with its heatsink external to the panel. 480V, 3-Phase, Continuous Rating Selection Table Continuous Regen Power Part Number Part Number Part Number Part Number Current Suppression Reactor Rated Input Voltage Power Coordination Reactor Fuse Holder(s) *1. NEMA Type 1 / IP20 Enclosure Required brackets are included with the drive. Drive Model Number R 1 0 0 0 E X T E R N A L H E AT S I N K K I T F O R N E M A T Y P E 1 4 0 0 V O LT C L A S S Rated Input Voltage...

Open the catalog to page 5
R1000 - 6

FRAME REFERENCE R1000 DIMENSIONS 2 0 0 - 2 4 0 V, 3 - P H A S E , D I M E N S I O N S A N D W E I G H T S Physical Dimensions (in) Reference Drawing Reference Drawing NOTE: PROTECTIVE COVERS ARE FACTORY INSTALLED TO THE TOP AND BOTTOM OF THE DRIVE TO MEET IP20 & NEMA TYPE 1 REQUIREMENTS, RESULTING IN AN AMBIENT TEMPERATURE RATING OF 104°F (40°C). REMOVE THESE COVERS WHEN OPERATING THE DRIVE WITHIN A PANEL TO OBTAIN THE MAXIMUM SURROUNDING AIR TEMPERATURE RATING OF 122°F (50°C). REMOVING THESE COVERS RESULTS IN AN ENCLOSURE RATING OF IP00. 1 For dimensions and weights on reactors, please see...

Open the catalog to page 6
R1000 - 7

NOTE: PROTECTIVE COVERS ARE FACTORY INSTALLED TO THE TOP AND BOTTOM OF THE DRIVE TO MEET IP20 & NEMA TYPE 1 REQUIREMENTS, RESULTING IN AN AMBIENT TEMPERATURE RATING OF 104°F (40C). REMOVE THESE COVERS WHEN OPERATING THE DRIVE WITHIN A PANEL TO OBTAIN THE MAXIMUM SURROUNDING AIR TEMPERATURE RATING OF 122°F (50°C). REMOVING THESE COVERS RESULTS IN AN ENCLOSURE RATING OF IP00. NOTE: PROTECTIVE COVERS ARE FACTORY INSTALLED TO THE TOP AND BOTTOM OF THE DRIVE TO MEET IP20 & NEMA TYPE 1 REQUIREMENTS, RESULTING IN AN AMBIENT TEMPERATURE RATING OF 104°F (40°C). REMOVE THESE COVERS WHEN OPERATING THE...

Open the catalog to page 7
R1000 - 8

Model # CIMR-RU Model # CIMR-RU 2A0035AXX 4A0035AXX 4A0043AXX NOTE: XX DENOTES AA-ZZ FOR ADDITIONAL DETAILS AND SPECIFICATIONS, CONSULT MANUAL. INT = INTERNAL COMPONENTS EXT = EXTERNAL HEATSINK TOT = TOTAL NOTE: XX DENOTES AA-ZZ INT = INTERNAL COMPONENTS EXT = EXTERNAL HEATSINK TOT = TOTAL FOR ADDITIONAL DETAILS AND SPECIFICATIONS, CONSULT MANUAL.

Open the catalog to page 8
R1000 - 9

Model # CIMR-RU Model # CIMR-RU 380/480 4A0150AXX NOTE: XX DENOTES AA-ZZ FOR ADDITIONAL DETAILS AND SPECIFICATIONS, CONSULT MANUAL. INT = INTERNAL COMPONENTS EXT = EXTERNAL HEATSINK TOT = TOTAL NOTE: XX DENOTES AA-ZZ INT = INTERNAL COMPONENTS EXT = EXTERNAL HEATSINK TOT = TOTAL FOR ADDITIONAL DETAILS AND SPECIFICATIONS, CONSULT MANUAL.

Open the catalog to page 9
R1000 - 10

PERIPHERAL DEVICES ELECTRICAL SCHEMATIC A C R E A C T O R S D I M E N S I O N S A N D S P E C I F I C AT I O N S Reactor Part Number 05P00620-0013 05P00620-0025 05P00620-0044 Dimensions Inductance Watt Loss L1 3 Phase Power Supply 50/60 Hz Ground Forced Operation Command Auto Operation Command External Fault Multi-Function Digital Inputs 24VDC, 8mA (Factory Defaults Are Shown) DIP Switch S2 Term Res On/Off External Base Block (Reserved) (Reserved) Jumpers and Switches (Factory Defaults Shown) Fault Reset Sequence Common Sink/Source mode selection wire link (default: Sink) Digital Output...

Open the catalog to page 10
R1000 - 11

Yaskawa is the leading global manufacturer of low and medium voltage variable frequency drives, servo systems, machine controllers and industrial robots. Our standard products, as well as tailor-made solutions, are well known and have a high reputation for outstanding quality and reliability. Yaskawa America, Inc. | Drives & Motion Division 1-800-YASKAWA | Email: info@yaskawa.com | yaskawa.com Document No. BL.R1000.01 | 11/19/2022 | © 2019 Yaskawa America, Inc.

Open the catalog to page 11

All Yaskawa America catalogs and technical brochures

  1. U1000

    17 Pages

  2. MV1000

    13 Pages

  3. SG400

    2 Pages

  4. GP7 AND GP8

    2 Pages

  5. FP605

    15 Pages

  6. iQrise

    2 Pages

  7. HV600

    19 Pages

  8. D1000

    2 Pages

  9. GA500

    9 Pages

  10. Sigma SD

    60 Pages

  11. GA800

    2 Pages

  12. L1000A

    2 Pages

  13. Deming Award

    2 Pages

  14. Z1000 Bypass

    2 Pages

  15. MP3200iec

    2 Pages

  16. P1000 Catalog

    52 Pages

  17. SGMMV

    20 Pages

  18. Bestact

    64 Pages

  19. A1000 Catalog

    58 Pages

  20. YASNAC 3000G

    203 Pages

  21. YASNAG 2000G

    58 Pages

Archived catalogs