Catalog excerpts
The Flexible and Intuitive Solution for Fan and Pump Applications. The P1000 drive provides simple, reliable, cost-effective control for variable-torque loads through 1000 HP. Specific application features, energy savings, and network connectivity make the P1000 a great choice for industrial fans and pumps. Drive Package Driven
Open the catalog to page 2Contents Features, Benefits, and Specifications Drives and Accessories Selection Mechanical Installation Planning Electrical Installation Planning Yaskawa Industrial Drives Family Global Service Network
Open the catalog to page 3Features and Benefits Exceptional Quality Enjoy peace of mind by knowing that you are considering a product from Yaskawa, the factory automation controls company with the highest reputation for quality and reliability. Historically, Yaskawa drives have demonstrated extremely high reliability with an average MTBF (mean time between failure) of 28 years or more. The new 1000 series products take reliability to the next level with a calculated design life that is twice as long as previous generations. Highly Integrated Design results in fewer parts and interconnections, reducing the number of...
Open the catalog to page 4Easy to Apply and Maintain Features, Benefits, and Specifications The P1000 is supported by user-friendly configuration tools. For local field access, the keypad interface features a multi-language LCD display, parameter storage, and application presets to make programming a simple task. It also has built-in memory for backup purposes. In addition, a USB Copy Unit can be loaded with a drive’s program for convenient portable transfer of configuration between an office environment and the factory floor. Fan and Pump Application Presets Conveyor Compressor Extruders Start-up time has been...
Open the catalog to page 5Features and Benefits Easy to Apply and Maintain Real Time Clock (RTC) Take advantage of the battery-backed clock that’s built into the P1000’s keypad display. With this feature, the P1000 can be controlled based on time of day, and can also provide timestamped event information. U3-21 = Year U3-22 = Month/Date U3-24 = Time of Fault PI Process Control Two separate process control loops are embedded in the P1000. One modifies drive speed based on setpoint and sensor feedback. A second control loop (with its own setpoint and feedback inputs) can be output to control something completely...
Open the catalog to page 6Features, Benefits, and Specifications Easy to Apply and Maintain Highly Reliable and Easily Replaceable Cooling Fans • • • Improved location for convenient access, even when mounted with heatsink external No tools required All ratings are 24Vdc powered Removeable I/O Terminal Board with Drive Backup Memory • • • • All parameter changes automatically saved to both main control board and I/O board Leave I/O connected when replacing a drive Configuration is downloaded to replacement drive Reduces MTTR (Mean Time To Repair) Underload Detection Monitors the load and will stop the system in the...
Open the catalog to page 7Features and Benefits Maximum Flexibility Enjoy a significant amount of standard control points. The P1000 can also expand to support popular communication networks. Digital Inputs (8) Analog Inputs (3) Pulse Inputs (1) Digital Outputs (4) 2 Form C Relays 2 Form A Relays Analog Outputs (2) RS485 Modbus RTU Communication Expansion Capability • • • • • Analog Output Module (3 additional outputs) DeviceNet EtherNet/IP Modbus TCP/IP PROFIBUS-DP Auxiliary Control Power Input Keep your drives communicating over the network, even while main power is removed. The Auxiliary Control Power Input uses...
Open the catalog to page 8Maximum Flexibility Features, Benefits, and Specifications Space Saving Features The P1000 offers world class power density resulting in an average size reduction of 30% as compared to previous generations (see individual rating dimensions). In addition, even more cabinet space can be saved by taking advantage of External Heatsink Mounting and Zero Side Clearance capability. Physical Size Reduction External Heatsink Solution (Side View) Zero Side Clearance (40°C max ambient) Type 12 Flange Configuration P1000 is available in all ratings as a Type 12 Flange configuration that allows for...
Open the catalog to page 9Features and Benefits Trip-free Operation Keep your applications running with features designed to avoid interruptions that are typical with demanding load conditions. • Optimal Decel automatically extends the programmed deceleration time based on the load condition and drive capability. • Overvoltage Suppression limits the DC bus voltage by modulating output frequency to keep the drive out of the regenerative region. • Overload Fault Prevention responds to heavy load conditions by adjusting output frequency and voltage to keep the drive’s current within operating limits. • Momentary Power...
Open the catalog to page 10Using variable speed on pumps and fans results is very large energy savings as compared to other fluid or air control methods (valves, guide vanes, dampers, etc.). Additionally, the P1000 provides even greater savings with its Energy Saving Control that reduces unnecessary magnetizing current at reduced speeds. BYPASS METHOD Features, Benefits, and Specifications Energy Savings Benefits of Variable Speed THROTTLING METHOD Reduce your energy bill and contribute towards a cleaner environment with sustainable features designed into the P1000. POWER SAVINGS ADJUSTABLE SPEED METHOD Comparison of...
Open the catalog to page 11Specifications 240V Class Model Rated Input Current*2 Rated Output Capacity*4,*5 Rated Output Current*5 Overload Tolerance 120% of rated output current for 60 sec. Carrier Frequency (User Adjustable) Three-phase 200 to 240 V (relative to input voltage) Rated Voltage/Rated Frequency Allowable Voltage Fluctuation Allowable Frequency Fluctuation External Option Power Supply Model Rated Output Current*5 Output Rated Output Capacity Overload Tolerance 120% of rated output current for 60 sec. Carrier Frequency (User Adjustable) Three-phase 200 to 240 V (relative to input voltage) Rated...
Open the catalog to page 12All Yaskawa America catalogs and technical brochures
-
U1000
17 Pages
-
MV1000NEMA 3R
5 Pages
-
MV1000
13 Pages
-
SG400
2 Pages
-
GP7 AND GP8
2 Pages
-
INTEGRATED SOLUTIONS
11 Pages
-
SIGMA TRAC II
9 Pages
-
R1000
11 Pages
-
iQPUMP AC DRIVE
13 Pages
-
FP605
15 Pages
-
iQrise
2 Pages
-
HV600
19 Pages
-
MACHINE CONTROL PRODUCTS
21 Pages
-
D1000
2 Pages
-
GA500
9 Pages
-
AC DRIVE SOFTWARE TOOLS
8 Pages
-
YASKAWA AC Drive-L1000A
524 Pages
-
1000 Series Low Voltage
15 Pages
-
Yaskawa IEC Robot Control
5 Pages
-
Yaskawa Type 3R Package
6 Pages
-
Sigma SD
60 Pages
-
GA800
2 Pages
-
MicroMax Marathon AC Motors
2 Pages
-
L1000A
2 Pages
-
BlackMax Marathon AC Motors
2 Pages
-
BlueMax Marathon AC Motors
4 Pages
-
NEMA Premium Efficiency XRI
2 Pages
-
Yaskawa AC Drives PLC
2 Pages
-
Deming Award
2 Pages
-
SigmaLogic7 Compact
2 Pages
-
Single Phase Converter
2 Pages
-
Sigma-7 Servo Systems
4 Pages
-
Z1000 Family of Drives Catalog
28 Pages
-
iQpump Family Catalog
20 Pages
-
Z1000 Bypass
2 Pages
-
Z1000 Drive, 3HP to 500HP
2 Pages
-
IEC - Comm Toolbox
2 Pages
-
MP3200iec
2 Pages
-
SGMMV
20 Pages
-
Bestact
64 Pages
-
Sigma II Servo Catalog
202 Pages
-
Sigma-5 Series Product Catalog
357 Pages
-
A1000 Catalog
58 Pages
-
YASNAC 3000G
203 Pages
-
LEGEND-MC (SMC-3010)
2 Pages
-
YASNAG 2000G
58 Pages
-
variable frequency drives
7 Pages
-
Sigma-5 Servo Family
8 Pages
-
Junma Series Servo
12 Pages
Archived catalogs
-
Flyer Yaskawa Factory Repair
2 Pages