YASKAWA HERMETICALLY SEALED CONTACT
Open the catalog to page 1Maximum Contacting Reliability, Minimized Size and Get them from Bestact Bestact is a hermetically sealed power switching contact unit having an excellent reputation in great number of actual applications as an interface element for control systems. Customer-proven features of Bestact include maximum reliability as well as unsurpassed environmental immunity and durability under adverse conditions such as high temperature, high humidity, existance of gas or vapor, vibration and surge. Large- and medium-capacity types are available depending upon customer's applications. 5 series of modification...
Open the catalog to page 2MEDICAL EQUIPMENT -HARBOR FACILITIES ipANSIT VEHICLES (DOOR INTERLOCK SW, AUTOMATIC TRAIN STOP (ATS)) KHEWOOLS, GENERAL INDUSTRY AND FACILITIES mpplQTIES "(HYDRO, COAL-FIRED, NUCLEAR) .^^STEEL'APPLICATION (BLAST FURNACE, CASTING, ROLLING AND MATERIAL HANDLING OPERATIONS)
Open the catalog to page 3BESTACT PRODUCTS IMPROVES RELIABILITY O FEATURES OF THE BESTACT SERIES OF PRODUCTS Bestact = Conventional Reed Switches + Mechanical Power Relays Bestact can perform the jobs of both conventional reed switches and power relays. Because a single Bestact replaces both, circuitry is simplified and entire circuit reliability rises significantly. A substantial cost savings can be achieved in that no contact protection (snubbers/diodes) is needed, minimal connections and reduced wiring circuitry is realized in actual circuit design. Vibration and Impact (Shock) Resistance In its weakest axis (when...
Open the catalog to page 4O SIMPLIFICATION OF CONTROL SYSTEM WHEN UTILIZING BESTACT Note: * Normally, arc protective circuitry need not be applied. However, if applied, extremely long lite can be obtained.
Open the catalog to page 5Medium-Capacity (Element) Hermetically Sealed Contact Type R24U (For general purpose) 3 Type R25U (For heavy duty) KACTQ^T Type R14U (For general purpose) ■^wWM^Wfc Type R15U (For heavy duty) Highly Reliable Contact Employing New Materials and Innovative Designs such as Wiping and Hammering Action, Bifurcated Contact and Back-Stop Mechanism 1. Sealed with an inert gas, ensuring freedom from aging and influences exerted by external environment. 2 . The twin contact and wiping effect assures outstanding con- tact reliability, probability of failure is extremely low. 3 . Quick action permits a larger...
Open the catalog to page 6Note *ln circuit with optcouoler. maximum 5V 10mA can be used.
Open the catalog to page 7RELIABILITY AND TYPICAL APPLICATIONS (Field Failure Rate of Relays) GENERAL PURPOSE Problems on reliability which have not been solved even by semi-conductor or photo-electric switch can be solved with Bestact. Nole : * 1 Excerpt from "Reliability Data" issued Dy public agency. * 2 Actual results of field failure rate *3- When no of failures is zero apply following No of tested contacts x tested hour (H)x 1G-C Applying jiS (Japanese Industrial Standard] 60% reliability level. 0.91 7 for zero failure (Typical Applications) * Industrial automatic control systems • Computer and peripheral devices...
Open the catalog to page 8Breaking Waveform of Bestact Breaking Waveform of Conventional Relay Typical Waveforms at Breaking AC Inductive Loads
Open the catalog to page 9ELECTRICAL LIFE WHEN APPLYING DC CIRCUIT (Type R14U, R15U) 24VDC CIRCUIT 48VDC CIRCUIT 115VDC CIRCUIT LOAD CURRENT^) LOAD CURRENT(A) LOAD CURPF.NT(A) Note 1 For inductive load. L/R = 1 ms of the like is attained if equipped with surge suppressor 2 Electrical lite of medium capaciiy type R24U and R25U when they are applied to DC (I) Derate the load current by 50% [2] Type R24L) and R25U cannot be used in any 230VDC circuit and any 115VDC where LOAD CURRENT(A| RELIABILITY FOR APPLYING DRY CIRCUIT Note 1 Operating Conditions • 10Hz of make break frequency • Resistance between contacts (opening and...
Open the catalog to page 10Medium-Capacity Type RI-DHMU, -E25MU (Standard type) Large-Capacity Type RI-BLJMU, -CrjMU (Standard type) Type RI-BHMHU, -CUMHU (High insulation type) Highly Reliable Interface Relays for Programmable Controllers, Microcomputer Control Systems 1 Assures outstanding reliability m circuits of 10OVAC/DC or greater as well as m electronic component circuits. 2 Universal output relay capability. Enables direct control over a wide range from TTL electronic level to large magnetic con- tactors or DC solenoid valves. 3. Requires no output relay board 4 Quick action in 5ms or less 5 . Excellent insulation...
Open the catalog to page 11COIL SPECIFICATIONS (With polarity) Note 1 Values shown above udicate ooeration dt arntnent temperature Ot 20°C 2 Coil resistance values can vary by ± 10%. 3 Type Rl-C may erroneously operate it the continuous allowable voltage are exceeded tor a short period of time
Open the catalog to page 12Medium-Capacity Type • Coil energizing sources For proper coil excitation, use a genuine DC power supply such as battery or three-phase full-wave rectified source whose ripple factor is 5% or less. It single-phase full-wave rectified source is used, a smoothing capacitor is needed to control the ripple to 5% Emj, MAX VALUE Of- PULSATING COMPONENT Rrnin . WIN VALUf-" OF PULSATiNC COMPONENT Emea" . DC MEAN I'ALUE The standard mounting direction is shown in figure (a) below. Where placing the relay mounting board horizontally as shown in figure (b), the operational voltage and releasing voltage...
Open the catalog to page 13TWO POLE TYPE INPUT/OUTPUT RELAYS Type RIW-M Highly Reliable Relays Solving Contact Problems of Mercury Relays Two pole type I/O relays can supersede mercury relays that are widely used for vehicles and signals. In addition, these highly reliable relays have solved many contact problems that may occur using mercury relays. Note : i Values tabulated indicate operations at ambient temperature ot 20"C 2 Each of NO and NC contact is independent Therefore, trie operating time of NO contact and NC contact may overlap Symbols and terminal markings (bottom view) Note 1 For connec'ion to coil terminals,...
Open the catalog to page 14; RELAY UNIT RIU SERIES High Density Mounting Design Incorporating Ultra-High Reliability Relays Ideally Used as I/O Relay Units for Micromputer Boards, 1. 4. 8, 10 and 16 contacts per unit, high density mounting 2. Can be energized using TTL electronic level signals or open collector input 3- Also available in a photo-coupler isolation type. 4 . Minimum space needed due to compact size 5. Provided with operational display (LED) 6. Incorporated features of the relay units: * Hermetically sealed contacts assure high long-term reliability even m adverse environments. • Large-capacity switching...
Open the catalog to page 1517 Pages
5 Pages
13 Pages
2 Pages
2 Pages
11 Pages
9 Pages
11 Pages
13 Pages
15 Pages
2 Pages
19 Pages
21 Pages
2 Pages
9 Pages
8 Pages
524 Pages
15 Pages
5 Pages
6 Pages
60 Pages
2 Pages
2 Pages
2 Pages
2 Pages
4 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
4 Pages
28 Pages
20 Pages
2 Pages
2 Pages
2 Pages
2 Pages
52 Pages
20 Pages
202 Pages
357 Pages
58 Pages
203 Pages
2 Pages
58 Pages
7 Pages
8 Pages
12 Pages
2 Pages