Drinking Water Monitoring READY-TO-USE SYSTEMS FOR MONITORING OF QUALITY RELEVANT PARAMETERS IN DRINKING WATER
Open the catalog to page 1Single-parameter Systems Single-parameter Systems • Single-parameter systems for measurement of pH/ORP, D.O., conductivity, free and total chlorine • Convenient pre-mounted panel for quick installation (chlorine only) • Low cost of ownership with no reagent consumption • Accuracy through integrated PID control function Transmitter • Integrated data logger • 2 current outputs, 2 relays, Modbus • Stable aluminium housing Electrode with flow-through armature • Specially designed flow-through vessel for each parameter guarantees reliable measurement results Flow control monitoring (optional) •...
Open the catalog to page 2Analog transmitter to directly connect analog pH/ORP electrodes • Available as NTC or PT1000 or Pt100 version • With integrated PID control function • For specific drinking water electrodes SenTix® ML 70 (ORP) Analog transmitter to directly connect analog oxygen sensors • Available as NTC or Pt1000 version • Wide measuring range (0 ... 20 mg/l) • For drinking water sensor Oxi ML 41 Analog transmitter to directly connect analog conductivity sensors • Available as NTC or Pt1000 version • Numerous measuring ranges (0 ... 500 mS/cm) • For drinking water sensor LR ML Analog transmitter to...
Open the catalog to page 3Multi-parameter System M U LT I L I N E 1 0 0 0 • Multi-parameter system for measurement of pH/ORP, D.O. conductivity, turbidity, free and total chlorine • Intuitive menu navigation • Excellent cost/performance ratio • No chemical consumables needed Multi-parameter transmitter PVC mounting plate, approx. 1000 x 750 x 12 mm (H x W x D) Calibration console Measuring transmitter for flow measurement Chlorine measuring sensor pH electrode Conductivity cell ORP electrode Turbidimeter Flow-through armature Pressure reducer Flow measuring unit Dosing valve to adjust the flow Inlet Constant flow: flow...
Open the catalog to page 4m Everything at a glance: MULTILINE 1000 With up to 6 individually configurable measuring channels, the MULTILINE 1000 terminal is a very flexible measuring system for drinking water analysis. The system is pre-assembled on a wall mounting panel for immediate use. Just connect the power and sample flow – and it’s ready to go. • Digital interface (RS 232/RS 422/RS 485) • 4 x 0/4 … 20mA outputs • 4 x potential-free relays for limit value/alarm function (timer function programmable) • Metal housing, protection class IP 65 • Large backlit display with touch screen Pre-mounted The MULTILINE 1000...
Open the catalog to page 5• Simple calibration • Integrated bubble trap • Ultrasonic cleaning of cuvette The nephelometric measurement is offered with or without ultrasonic cleaning of the flow-through cuvette. The user can also select between infrared light measurement according to DIN 7027 and white light measurement according to US EPA 180.1. Technical Data Turb 2000 Measuring range ± 2% of the measured value or ± 0.02 NTU below 40 NTU (the higher value), ± 5% of the measured value above 40 NTU Power supply Analyzer for Free and Total Chlorine Chlorine 3000 • Low consumption of reagents • 30 days maintenance-free...
Open the catalog to page 6Technical Data Single-parameter system - panel (chlorine only) Pre-assembled multi-parameter panel Allowable overpressure before dosing valve (inlet): 0 … 10 bar, after dosing valve 0 … 6 bar, according to sensor before dosing valve (inlet): 0 … 10 bar, after dosing valve 0 … 6 bar, according to sensor Flow control flow-through measurement (optional), minimum 30 l/h (0.5 l/min) flow-through measurement (optional), minimum 30 l/h (0.5 l/min) fixed pipe joint (DN 10), pressureless. gravity flow to spout, Ø 40 mm PVC pipe Model, Parameter Measuring range 0 … 500 mS/cm, different ranges can be...
Open the catalog to page 7Order Information Drinking Water Systems MULTILINE 1000 Drinking water monitoring system with flow measurement, pressure controller, dosing valve, pre-mounted on water repellent panel. DN 10 joints with: MULTILINE 1000 Controller/Terminal, 240 VAC MULTILINE 1000 Controller/Terminal, additionally with flow measurement, 240 VAC Configurable parameters/inputs Conductivity measurement with integrated temperature sensor (LR ML) (input module, two electrodes conductivity cell (0.1 … 20 mS/cm), connection cable) pH measurement (SenTix® ML 70) (input module, pH electrode for drinking water (pH...
Open the catalog to page 8All Xylem Analytics Germany Sales GmbH & Co. KG. catalogs and technical brochures
-
The system 282/284
8 Pages
-
ProfiLine Handhelds
8 Pages
-
IQ Sensor Net
20 Pages
-
inoLab® Multi IDS
8 Pages
-
inoLab® 7000 Series
8 Pages
-
OPTi® Food & Beverage
2 Pages
-
OPTi® Beer & Wine
2 Pages
-
OPTi® Automotive
2 Pages
-
Flow-through Refractometry
4 Pages
-
Bellingham + Stanley
8 Pages
-
ADP600 Series Polarimeters
6 Pages
-
Room Climate Monitor RM 100
4 Pages
-
HACCP never was as easy
8 Pages
Archived catalogs
-
Viscometry Catalog
35 Pages
-
The new CHEMfit 340 armature
56 Pages
-
Laboratory Electrodes
5 Pages
-
Titration Catalogue
57 Pages
-
The new titrators and burettes
48 Pages
-
Meters and Electrodes catalog
59 Pages
-
Process Equipment
160 Pages
-
pH handbook
100 Pages