Drinking Water Monitoring
8Pages

{{requestButtons}}

Catalog excerpts

Drinking Water Monitoring - 1

Drinking Water Monitoring READY-TO-USE SYSTEMS FOR MONITORING OF QUALITY RELEVANT PARAMETERS IN DRINKING WATER

Open the catalog to page 1
Drinking Water Monitoring - 2

Single-parameter Systems Single-parameter Systems • Single-parameter systems for measurement of pH/ORP, D.O., conductivity, free and total chlorine • Convenient pre-mounted panel for quick installation (chlorine only) • Low cost of ownership with no reagent consumption • Accuracy through integrated PID control function Transmitter • Integrated data logger • 2 current outputs, 2 relays, Modbus • Stable aluminium housing Electrode with flow-through armature • Specially designed flow-through vessel for each parameter guarantees reliable measurement results Flow control monitoring (optional) •...

Open the catalog to page 2
Drinking Water Monitoring - 3

Analog transmitter to directly connect analog pH/ORP electrodes • Available as NTC or PT1000 or Pt100 version • With integrated PID control function • For specific drinking water electrodes SenTix® ML 70 (ORP) Analog transmitter to directly connect analog oxygen sensors • Available as NTC or Pt1000 version • Wide measuring range (0 ... 20 mg/l) • For drinking water sensor Oxi ML 41 Analog transmitter to directly connect analog conductivity sensors • Available as NTC or Pt1000 version • Numerous measuring ranges (0 ... 500 mS/cm) • For drinking water sensor LR ML Analog transmitter to...

Open the catalog to page 3
Drinking Water Monitoring - 4

Multi-parameter System M U LT I L I N E 1 0 0 0 • Multi-parameter system for measurement of pH/ORP, D.O. conductivity, turbidity, free and total chlorine • Intuitive menu navigation • Excellent cost/performance ratio • No chemical consumables needed Multi-parameter transmitter PVC mounting plate, approx. 1000 x 750 x 12 mm (H x W x D) Calibration console Measuring transmitter for flow measurement Chlorine measuring sensor pH electrode Conductivity cell ORP electrode Turbidimeter Flow-through armature Pressure reducer Flow measuring unit Dosing valve to adjust the flow Inlet Constant flow: flow...

Open the catalog to page 4
Drinking Water Monitoring - 5

m Everything at a glance: MULTILINE 1000 With up to 6 individually configurable measuring channels, the MULTILINE 1000 terminal is a very flexible measuring system for drinking water analysis. The system is pre-assembled on a wall mounting panel for immediate use. Just connect the power and sample flow – and it’s ready to go. • Digital interface (RS 232/RS 422/RS 485) • 4 x 0/4 … 20mA outputs • 4 x potential-free relays for limit value/alarm function (timer function programmable) • Metal housing, protection class IP 65 • Large backlit display with touch screen Pre-mounted The MULTILINE 1000...

Open the catalog to page 5
Drinking Water Monitoring - 6

• Simple calibration • Integrated bubble trap • Ultrasonic cleaning of cuvette The nephelometric measurement is offered with or without ultrasonic cleaning of the flow-through cuvette. The user can also select between infrared light measurement according to DIN 7027 and white light measurement according to US EPA 180.1. Technical Data Turb 2000 Measuring range ± 2% of the measured value or ± 0.02 NTU below 40 NTU (the higher value), ± 5% of the measured value above 40 NTU Power supply Analyzer for Free and Total Chlorine Chlorine 3000 • Low consumption of reagents • 30 days maintenance-free...

Open the catalog to page 6
Drinking Water Monitoring - 7

Technical Data Single-parameter system - panel (chlorine only) Pre-assembled multi-parameter panel Allowable overpressure before dosing valve (inlet): 0 … 10 bar, after dosing valve 0 … 6 bar, according to sensor before dosing valve (inlet): 0 … 10 bar, after dosing valve 0 … 6 bar, according to sensor Flow control flow-through measurement (optional), minimum 30 l/h (0.5 l/min) flow-through measurement (optional), minimum 30 l/h (0.5 l/min) fixed pipe joint (DN 10), pressureless. gravity flow to spout, Ø 40 mm PVC pipe Model, Parameter Measuring range 0 … 500 mS/cm, different ranges can be...

Open the catalog to page 7
Drinking Water Monitoring - 8

Order Information Drinking Water Systems MULTILINE 1000 Drinking water monitoring system with flow measurement, pressure controller, dosing valve, pre-mounted on water repellent panel. DN 10 joints with: MULTILINE 1000 Controller/Terminal, 240 VAC MULTILINE 1000 Controller/Terminal, additionally with flow measurement, 240 VAC Configurable parameters/inputs Conductivity measurement with integrated temperature sensor (LR ML) (input module, two electrodes conductivity cell (0.1 … 20 mS/cm), connection cable) pH measurement (SenTix® ML 70) (input module, pH electrode for drinking water (pH...

Open the catalog to page 8

All Xylem Analytics Germany Sales GmbH & Co. KG. catalogs and technical brochures

  1. IQ Sensor Net

    20 Pages

Archived catalogs

  1. pH handbook

    100 Pages