Product catalog summary
Overview: The ICAM IFT-P is an air-sampling smoke detector designed for very early fire detection. It operates within an alarm sensitivity range of 0.01% to 20% obscuration/m and covers areas up to 2000 m². It is suitable for various environments, including telecommunications, IT facilities, and heavy industrial settings.
Functionality: The detector uses a pipe network to draw air samples, which are then filtered and analyzed in a laser detection chamber. It features programmable alarm states (Alert, Action, Fire 1, Fire 2) with corresponding LEDs and output relays for interfacing with alarm systems.
Product Features: The IFT-P supports RS232, RS485, and TCP/IP communication interfaces for configuration and management. It can connect to remote displays and email services. The detector includes a high-pressure aspirator for efficient detection and a dual-element thermal sensing system for airflow monitoring.
Specifications: The detector operates on a nominal 24 VDC supply with a current range of 500 mA to 1.2 A. It is equipped with a 2000 Pa centrifugal air pump and has dimensions of 254 mm x 180 mm x 165 mm. Operating conditions range from 0 to 39°C, with tested conditions from -10 to 55°C. It supports a single fire detection zone with dual pipe sampling.
Approvals and Compliance: The IFT-P is approved by UL, ULC, FM, CCC, CE, VdS, NF, and EN 54-20 standards. It is classified under different classes based on the number of sampling holes and obscuration levels.
Ordering Information: The IFT-P is available with TCP/IP connectivity and optional relay and analog output modules. Dimensions and additional specifications are provided for installation purposes.
See more

Catalog excerpts

ICAM IFT-1

The ICAM IFT-P detector is an air-sampling system with an alarm sensitivity range from 0.01% to 20% obscuration/m (0.003% to 6.10% obscuration/ft). This detector is classified as a Very Early Warning Smoke Detector that can reliably detect fire at an early stage, and low to high concentrations of smoke over an area of up to 2000 m2 (21 500 ft2). The detector is configurable for a variety of environments, providing an ideal fire detection solution for telecommunications and IT facilities, and heavy industrial environments such as chemical plants, factories, warehouses and mining facilities. How it works The IFT-P detector draws air through sample holes in a pipe network, then filters and analyzes the sample in a laser detection chamber. Individually programmable alarm states (Alert, Action, Fire 1 and Fire 2) are shown on the display, which contains four alarm LEDs and an OK/Fault LED. Dedicated output relays also provide interfaces for each alarm state and device faults. Product Features Programming and Configuration RS232, RS485 and TCP/IP communication interfaces are available to connect to Xtralis Configuration and Fire System Management software packages: Xtralis VSC and Xtralis VSM4. RS485 interfaces also allow connections to remote displays, and the TCP/IP Ethernet interface can provide access to an email messaging service. Inputs and Outputs The IFT-P detector supports a maximum of three optional modules, which provide the detector with additional programmable output relay interfaces, and 4 to 20 mA analog outputs. Aspiration and Flow Sensing The aspirator is a 2000 Pa high pressure and high volume fan, which provides superior detection times over long pipe lengths and reliable detection in high air flow environments. Airflow in each pipe is monitored by a dual element thermal sensing system, with airflow faults indicated on the display and to monitoring equipment. Features • Single zone • Dual pipe air sampling • 0.01% to 20% obscuration/m (0.003% to 6.10% obs/ft) • 4 Alarms - Alert, Action, Fire 1, Fire 2 • 2 x 282 m (2 x 925 ft) sampling pipe • Enhanced performance aspirator • Ethernet TCP/IP • RS232 and RS485 Modbus • 5 relay outputs and expandable • Optional relay module and 4 to 20 mA analog output module • Event Log • Area coverage of up to: - 2000 m2 (21,500 ft2) for VdS installations - 1600 m2 (17,200 ft2) for NF installations - 850 m2 (9,150 ft2) for UL installations Listings/Approvals • UL • ULC • FM • CCC • CE • VdS • NF • EN 54-20 - Class A (12 holes / 0.04% obs/m) - Class B (80 holes / 0.02% obs/m) - Class C (80 holes / 0.04% obs/m) Classification of any configuration is determined using ASPIRE. Regional approvals listings and regulatory compliance vary between ICAM models.

 Open the catalog to page 1
ICAM IFT-2

Supply Voltage: Nominal 24 VDC Supply Current: 500 mA (min) to 1.2 A (max) Capacitive Loading: Nominal 5,000 uF Aspirator: 2000 Pa Centrifugal air pump Operating Conditions: Ambient: * 0 to 39°C (32 to 103°F) Tested to: -10 to 55°C (14 to 131°F) Sampled Air: -20 to 60 °C (-4 to 140°F) Humidity: 10 to 95% RH (non-condensing) Sampling Pipe Size: Outer Diameter: 25 mm, or; 1.05 in (3/4” pipe) with adaptor Sampling Network: Zones: 1 Fire detection zone Pipe Length: 2 x 282 m (2 x 925 ft.) Alarm Sensitivity Range: 0.01% to 20% obs/m (0.003% to 6.10% obs/ft) Alarm Settings: Alarm levels: Alert, Action,...

 Open the catalog to page 2