Product catalog summary
Overview: The ICAM IAS Air-sampling Smoke Detection systems, IAS-1 and IAS-2, offer flexible solutions for various applications, including industrial spaces, special accommodations, and office environments. These systems replace traditional spot detectors and provide advanced smoke detection capabilities.
How it Works: The IAS systems draw air from protected areas through sampling holes in a pipe network. The air is filtered and analyzed by point detectors. IAS-1 has one inlet pipe, while IAS-2 has two, with options for one or two detectors per system. Various detector technologies can be used, including photoelectric, ionization, heat, and CO detectors.
Detection Strategies: The systems support multiple detection strategies such as single or dual addressable area detection, redundant detection, multi-criteria detection, and coincident or double-knock detection. These strategies enhance configuration simplicity and cost-effectiveness.
Features: Key features include single or dual channel fire detection, multiple configuration options, up to 100 m per sampling pipe, microprocessor control, high fan capacity, integral display and programmer, field serviceable air filter, adjustable aspirator speed, and IP65 enclosure.
Listings/Approvals: The systems are approved under EN54-20 (VdS), CE EMC, CPR, and ActivFire standards.
Specifications: Supported detectors include 1 or 2 analog addressable or conventional spot detectors. The systems operate at 24 VDC nominal voltage, with a maximum current of 300 mA. Dimensions are 259 mm x 184 mm x 166 mm. Operating conditions range from -10 to 55 °C, with humidity levels of 10 to 95% RH.
Flow Monitoring and Reporting: The systems feature adjustable high and low flow thresholds, with flow failure reported as a device fault via relays. IAS-1 has one fault relay, while IAS-2 has two.
Ordering Information: The IAS-1 system is available with one inlet, and the IAS-2 system with two inlets. Various baffles for spot detectors are available, and configuration options allow for different detection strategies.
Dimensions: Detailed dimensions are provided for installation and integration purposes.
Legal and Trademark Information: The document includes disclaimers regarding accuracy and reliability, and notes on trademark ownership by Xtralis.
See more

Catalog excerpts

ICAM IAS-1

IAS-1 & IAS-2 Features • Single or dual channel fire detection • Multiple configuration options • Multiple detection strategies • Up to 100 m (328 ft) per sampling pipe • Microprocessor controlled • Highest fan capacity in its class • Integral display and programmer • Field serviceable air filter • Adjustable aspirator speed with airflow monitoring • IP65 enclosure The ICAM IAS Air-sampling Smoke Detection systems provide a flexible solution to meet the unique needs of numerous applications including industrial spaces such as cable tunnels, the tamper-proof and unobtrusive requirements of special accommodation, or can simply be used to replace spot (point) detectors in office environments. The IAS systems actively draw air from the protected area through sampling holes in a pipe network. Sampled air is then filtered before being analyzed by conventional or analog point detectors incorporated in the systems. The IAS system is available with one inlet pipe (IAS-1) or two inlet pipes (IAS-2), and can be fitted with one or two detectors per system. A number of detector technology types (photoelectric, ionization, heat, CO etc.) from a range of leading technology providers may be used. The systems utilize a high performance aspirator and software configurable flow monitoring circuitry. Air flow level is displayed on a ten element bar graph that can be adjusted for high and low flow thresholds, and flow failure is reported as a device fault via relays to the loop. Detection Strategies The systems may be configured for a number of detection strategies including: • single or dual addressable area detection • redundant detection • multi-criteria detection • coincident or double-knock detection Installer-specifiable point detectors offer benefits in simplicity of configuration and cost effectiveness. In circumstances where the premises are already protected by point detectors, the IAS system is easily introduced onto the existing fire alarm control panel signaling circuit by fitting equivalent detectors into the system*. * Subject to IAS system approval for the fitted spot (point) detector • EN54-20 (VdS) (Sensitivity Class dependant upon poi

 Open the catalog to page 1
ICAM IAS-2

Detector Configuration Options Several configuration options are available for the IAS-1 and IAS-2 systems: • IAS-1 system - one or two spot (point) detectors • IAS-2 system - two spot (point) detectors IAS-1 systems fitted with one spot (point) detector are capable of providing single area detection, but IAS-1 and IAS-2 systems fitted with two detectors are able to provide a number of detection strategies. The table below describes the recommended configuration options to fit the selected detection strategy when two spot (point) detectors are fitted into an IAS system. f Subject to local codes...