Catalog excerpts
External Interlock: Openoff, closed on. HV Enable/Disable: 0-1.5 V off, 2.5-15 V on. > Output Cable: Detachable, 8 foot.RG8U shielded high voltage coaxial cable is provided. Controls: A DB15S D-subminiatureconnector, and mating plug, is provided for all control input functions. These include common, + 10 volt reference, interlock, current monitor,current program, voltage monitor, voltage program, TTL, ground, and local control. > (From 5% to 100% rated voltage. Allunits operate down to zero output with very slight degradation of performance.) Input: > 105-125V RMS or 210-250V RMS(must be...