Model DX-102F RTN Gaussmeter Users’ Manual MAN-DX102F-REV01-2020-EN This Document Contains Operation Information Printed in China Edition 1, Mar., 2020
Open the catalog to page 1Model DX-102F Users’ Manual REV01 THIS LIMITED WARRANTY DOES NOT APPLY TO MISUSE, IMPROPER MAINTENANCE or CALIBRATION, or UNAUTHORIZED MODIFICATION, REPAIR or REPLACEMENT. Limited Warranty Statements 1. This Limited Warranty only applies to Products sold in Mainland of China. 2. We warrants that this Product will be free from defects in materials and workmanship for Warranty Period of TWELVE MONTHS, except for fragile items, which may contains hall probes of any model, and consumables, which may contains battery cells. 3. During the Warranty Period, we will repair or replace the Product or its...
Open the catalog to page 2Model DX-102F Users’ Manual REV01 Safety Information The following general safety precautions must be observed during all phases of operation, service, and repair of this instrument. Failure to comply with these precautions or with specific CAUTIONs elsewhere in this manual violates safety standards of design, manufacture, and intended use of the instrument. We assumes no liability for the customer's failure to comply with these requirements. Summary 1. This Product is portable and handheld. All the internal levels have no relationship with Protection Earth, at the circumstance of no charging...
Open the catalog to page 3Model DX-102F Users' Manual REV01
Open the catalog to page 4Model DX-102F Users' Manual REV01 Inspect shipping containers for external damage. If damage or loss is apparent, please notify us immediately. 1. Open shipping containers. Check with packing list in this page, to ensure that the instrument, sensor(s), accessories and CDs were received, and inspect for damage. 2. Be sure to inventory all components supplied, before discarding any shipping materials. 3. If there is damage to the instrument in transit, be sure to file proper claims promptly with carrier and insurance company. 4. In case of parts or accessories shortage, advice us immediately. We...
Open the catalog to page 5Model DX-102F Users' Manual REV01
Open the catalog to page 6Model DX-102F Users' Manual REV01
Open the catalog to page 7Model DX-102F Users' Manual REV01
Open the catalog to page 8Model DX-102F Users' Manual REV01
Open the catalog to page 9Model DX-102F Users' Manual REV01 Figure 2-4 Standard Display Interface with No Probe Mated... 2-6 Figure 3-4 Transverse Probe Orientation for Polar Sign of "+" or N Figure 3-5 Axial Probe Orientation for Polar Sign of "+" or N Figure 3-7 Frequency Limit to Sinusoidal Field (DX-102F1 Only) Figure 3-8 RMS Frequency Response at 60% Given Range (DX-102F1 Only) Figure 3-17 Prolific USB-to-Serial Comm Port(COMn) Property Window
Open the catalog to page 10Model DX-102F Users' Manual REV01 Table 3-3 Error of BAVE from BRMS (Calibration Factor of 1.11)... 3-6 Table A-6 ASCII (American Standard Code for Information Exchange)
Open the catalog to page 11Model DX-102F Users’ Manual REV01 This Page Intentionally Left Blank
Open the catalog to page 12Model DX-102F Users' Manual REV01 This chapter contains specifications that apply to DX-102F portable RTN Gaussmeter, as well as information concerning options and safety requirements. The remaining chapters in this manual contain instructions for install, operating, programming, and sensors and accessories, listed in Table 1-1. Table 1-1 Contents in Remaining Chapters tab-MAN-DX102F-0001 If you are a first-time user, start with this manual, paying particular attention to Chapter 2 for correct installation. Read chapter 3 for learn front panel operation. Programming users should then read Chapter...
Open the catalog to page 13Model DX-102F Users' Manual REV01 3 3/4-digit, 1 part in 3,000 resolution on 30kG range. • Temperature coefficient of probe: ±(0.05%RD+0.02G)/°C, (probe tip at 25°C±10°C). • Linearity error of less than ±0.5% on 30kG range, less than ±0.2% on other ranges. • True RMS measurement, within band of 30Hz to 10kHz and crest factor of less than 5, to avoid average errors of high crest factor waveforms. • Effective measures of 0.33% to 100% range, rated range of 1% to 100% range. • Accuracy in rated range: 3% READ (30Hz to 10kHz, sinusoidal) • Zero error is less than 0.16% range. • Temperature coefficient...
Open the catalog to page 14Model DX-102F Users' Manual REV01 Specifications of DX-102F are listed in Table 1-2.
Open the catalog to page 15Model DX-102F Users' Manual REV01
Open the catalog to page 16Model DX-102F Users' Manual REV01 Model DX-102F Users' Manual REV01 [1] Rated accuracy is obtained in the ambient temperature range of 15 to 35 °C. [2] Higher or lower temperature leads mechanical stress of probe tip and internal wires, and may result in probe destruction. [3] The instrument and probe should warm up for at least 1 minute for rated accuracy. Additional specifications of DX-102F portable Gaussmeter are provided in Table 1-3. Table 1-3 Additional Specifications TAB-MAN-DX102F-0003 Figure 1-1 shows the standard display interface of a turned on DX-102Fo
Open the catalog to page 17Model DX-102F Users' Manual REV01 Firmware version of this product can be read from returned 17-character serial number by sending interface inquiry *IDN? [CR] (see Figure 1-2). The serial number can as well be displayed when the instrument is returned to factory default settings. Figure 1-2 Read Firmware Version from Serial Number Calibration period of DX-102F with its probes DX-102F1/DX-102F2 is one year. DX-102F with its probes are calibrated at time of shipment from the factory. All the published specifications listed in Table 1-2 are certified within one year. When calibration period is...
Open the catalog to page 18Model DX-102F Users’ Manual REV01 2 INSTALLATION 2.1 General This chapter covers general installation instructions of DX-102F portable RNT1 Gaussmeter: 2.2 Unpacking & Repackaging. 2.3 Definition of Top Panel Connections. 2.4 Battery & Maintenance. 2.5 Initial Setup & Checkout Procedure. 2.2 Unpacking & Repackaging After inspection and unpacking, please properly reserve the suitcase and original spacer. Since hall probes are fragile product, in the shipment, they should be fixed in the protection tube, and be packaged in the suitcase, protected by inner spacer. Please properly reserve the protection...
Open the catalog to page 196 Pages
18 Pages
18 Pages
18 Pages
32 Pages
16 Pages
6 Pages
7 Pages
8 Pages
12 Pages