1. Catalogs
  2. Xiamen Dexing Magnet Tech. Co., Ltd.
  3. User manual of DX-2012SD Soft magnetic material DC test system
video corpo

User manual of DX-2012SD Soft magnetic material DC test system
1 /29Pages

User manual of DX-2012SD Soft magnetic material DC test system

User manual of DX-2012SD Soft magnetic material DC test system
1 /29Pages

Catalog excerpts

User manual of DX-2012SD Soft magnetic material DC test system-1

厦门盈德兴磁电科技有限公司 Xiamen Dexing Magnet Tech. Co., Ltd. The user manual of DX-2012 Soft magnetic material DC test system Chapter 1 Composition of DC measuring system for soft magnetic materials 1. The composition is as following: 1.1 Excitation power supply 1.2 Fluxmeter 1.3 DA/AD module 1.4 Computer 1.5 Printer 2. The interrelationship is shown in the figure below: Add: Unit 409, No.992, Anling Road, Huli Dist, Xiamen, China Email: info@dexinma

 Open the catalog to page 1
User manual of DX-2012SD Soft magnetic material DC test system-2

unmMxm&mmtiL&nXiamen Dexing Magnet Tech. Co., Ltd.Chapter 2 The hardware of DX-2012SD DC measuring system for soft magnetic materials1 Excitation current source Power supply requirements: 220V ± 10%, 5A, 50Hz. 3 DA/AD module AD converter: 12-bit AD, speed 2000-20000 channels/second. Channel input impedance: 1 megaohm. Noise (peak): less than ± 1LSB (typical, 500 sampling points) 4 Computer Recommended configuration: CPU dual-core 2.4GHz or above, memory 2G or above, hard disk 100G or above, motherboard G41 or above, display 19 inches, Windows XP or above operating system. 5 Printer PC compatible...

 Open the catalog to page 2
User manual of DX-2012SD Soft magnetic material DC test system-3

厦门盈德兴磁电科技有限公司 Xiamen Dexing Magnet Tech. Co., Ltd. Chapter 3 The software of DX-2012SD DC measuring system for soft magnetic materials DX2012SD soft magnetic DC measurement system test software is green version, which can be directly opened and used without complicated installation process. However, in order to better protect the common interests of users and the company, the software needs to be registered to operate normally. The platform on which the software system runs is based on. NET3.5. The required data acquisition module also needs to be installed to use, so the software installation...

 Open the catalog to page 3
User manual of DX-2012SD Soft magnetic material DC test system-4

厦门盈德兴磁电科技有限公司 Xiamen Dexing Magnet Tech. Co., Ltd. Then select "Browse the computer to find the driver software(S)", as shown in the following figure Then click "Select from the list of computer device drivers", and the computer will pop up the following window: Add: Unit 409, No.992, Anling Road, Huli Dist, Xiamen, China Email: info@dexinma

 Open the catalog to page 4
User manual of DX-2012SD Soft magnetic material DC test system-5

厦门盈德兴磁电科技有限公司 Xiamen Dexing Magnet Tech. Co., Ltd. Click "Install from Disk", and a "Install from Disk" window will pop up on the computer. Then find the "driver" under this test software package and select it, as shown in the following figure Then click "OK", and then click "Next". The computer starts to install the sampling module driver, as shown in the following figure: Add: Unit 409, No.992, Anling Road, Huli Dist, Xiamen, China Email: info@dexin

 Open the catalog to page 5
User manual of DX-2012SD Soft magnetic material DC test system-6

厦门盈德兴磁电科技有限公司 Xiamen Dexing Magnet Tech. Co., Ltd. Click "Finish" to complete the installation of the computer, and the prompt is as follows: This completes the installation of the sampling driver. 3. Install the. NET 3.5 platform. Double click dotNetFx35setup.exe under the dotNetFramework folder, and follow the prompts to click "Next" to complete the installation. The installation process may take more than ten minutes, please be patient and wait. Please restart the computer after installation. 4 Register the software. Double click on the application DX2012SD.EXE, and a registration window will...

 Open the catalog to page 6
User manual of DX-2012SD Soft magnetic material DC test system-7

unmMxm&mmtiL&nXiamen Dexing Magnet Tech. Co., Ltd.Chapter 4 Operating Instructions for DX-2012SD Soft Magnetic Material DC Measurement System In order for you to use this instrument better and faster, please read the instructions in this chapter carefully before using this instrument. Scope of use: The DX2012SD DC measuring device for soft magnetic materials is mainly used to measure the basic magnetization curve and hysteresis loop of various soft magnetic materials such as soft ferrite, pure iron, silicon steel, permalloy, amorphous and nanocrystalline under DC static state, and accurately...

 Open the catalog to page 7
User manual of DX-2012SD Soft magnetic material DC test system-8

厦门盈德兴磁电科技有限公司 Xiamen Dexing Magnet Tech. Co., Ltd. 3. Saturated magnetic induction strength Bs: refers to the magnetic induction strength B of a material that does not change after the excitation magnetic field strength H reaches a certain strength. The corresponding magnetic induction strength is defined as the saturated magnetic induction strength Bs of the material. For different materials, the saturation magnetic induction strength Bs varies, and currently available soft magnetic materials are generally below 2.8T. 4. Residual magnetism Br: After saturation magnetization of the material,...

 Open the catalog to page 8
User manual of DX-2012SD Soft magnetic material DC test system-9

厦门盈德兴磁电科技有限公司 Xiamen Dexing Magnet Tech. Co., Ltd. Chapter 5 1. DX-2012SD Inspection of Soft Magnetic DC Measuring System Accessories Please check whether the system accessories are complete, and all accessories are as follows: 1.1. A set of computer (or notebook) with DX2012SD software installed; 1.2. One DX2012SD excitation power supply; 1.3. A pair of gold plated test clips; 1.4. One power cord; 1.5. One USB cable; Please connect all the connecting wires after all the accessories are complete. The following mainly introduces DX-2012SD excitation power supply and DX-2012SD measurement software....

 Open the catalog to page 9
User manual of DX-2012SD Soft magnetic material DC test system-10

unmMxm&mmtiL&nXiamen Dexing Magnet Tech. Co., Ltd. Res fluxmeter reset key: Press this key to reset the fluxmeter meter reading on the software interface. Cooling fan: Heat the power amplifier of the excitation power supply. Please ensure the smooth and normal operation of this vent. Data interface: Connect the USB interface of the computer to supply power to the data acquisition module and communicate data. Power socket: connected to mains 220V/50Hz, with a built-in fuse at the lower end of the socket, which is 10A. The entire software testing interface can be divided into the following nine...

 Open the catalog to page 10
User manual of DX-2012SD Soft magnetic material DC test system-11

厦门盈德兴磁电科技有限公司 Xiamen Dexing Magnet Tech. Co., Ltd. 3.1 Software men File: There are four drop-down menus: "New File", "Open File", "Load File", and "Exit Software"; Under "New File", there are "New Index" and "New Data". An index is equivalent to a table of contents file that can hold hundreds of test data. The software can only display test data under one index at a time. The test data below the index should not be too much, as this may cause the computer to run stuck when the software opens the index. It is recommended that the operator create a new index before each test. Edit: There are "Delete...

 Open the catalog to page 11