Identification of the Substance and Company: This Material Safety Data Sheet (MSDS) is for Rubber Magnet, prepared by EMTEK (Guangzhou) Co., Ltd. for XIAMEN DEXING MAGNET TECH. CO., LTD., including contact details for both companies.
Hazards Identification: The rubber magnet is not classified as hazardous under regulation (EC) No. 1272/2008, posing no significant physical, health, or environmental hazards.
Composition/Information on Ingredients: The rubber magnet consists mainly of Ferric oxide (90%), Strontium carbonate (5%), and Chlorinated polyethylene (5%).
First Aid Measures: For inhalation, move to fresh air and seek medical aid if necessary. For skin contact, wash with water. If ingested, do not induce vomiting and seek medical advice.
Fire-Fighting Measures: Use water fog, alcohol-resistant foam, dry powder, or carbon dioxide as extinguishing media. Firefighters should wear protective gear and self-contained breathing apparatus.
Accidental Release Measures: Use protective equipment, ensure proper ventilation, prevent material from entering waterways, and dispose of it in a closed container.
Handling and Storage: Store in a cool, well-ventilated area away from ignition sources. Use protective clothing and ensure good ventilation during handling.
Exposure Controls/Personal Protection: Use explosion-proof ventilation and personal protective equipment such as respirators, safety glasses, and gloves.
Physical and Chemical Properties: The rubber magnet is a solid, black, and odorless material, insoluble in water.
Stability and Reactivity: The product is stable under recommended conditions but should be kept away from strong oxidizing agents.
Toxicological Information: Not classified as carcinogenic. Inhalation or ingestion may be harmful, and it may cause irritation upon contact with skin or eyes.
Ecological Information: No specific data available, but large-scale release may cause environmental pollution.
Disposal Considerations: Not considered hazardous waste. Dispose of according to local regulations, avoiding water contamination.
Transport Information: Not classified as dangerous for transport by air, land, or sea. Keep away from direct sunlight and high temperatures during transport.
Regulatory Information: Complies with Regulation (EC) No 1272/2008 and the Globally Harmonized System (GHS).
Other Information: Includes definitions of various regulatory and safety terms used throughout the MSDS.
General Information: Issued by EMTEK (Guangzhou) Co., Ltd. on April 22, 2022, including safety and handling information.
Disclaimer: Information is based on reliable sources, but no warranty is given regarding accuracy. Handling, storage, use, and disposal are beyond the issuer's control, and they disclaim liability for related loss or damage.
Test Report Conditions: Valid only with a signature and specialized stamp. Cannot be reproduced without written consent from EMTEK. Confidential and intended for the client, not for advertising without permission.
Liability and Usage: EMTEK is not liable for loss or damage from the use of the report. Cannot be used as a basis for legal action against the company. Clients must inform EMTEK if using the report in legal proceedings before submitting samples for testing.
Data Retention: Test data retained for ten years, after which they are disposed of. EMTEK is not responsible for providing data after the retention period or for damages arising from the use of the report.
Key Terms: References several safety and exposure standards, including STEL, TWA, OSHA, and others.
See more

Catalog excerpts

Rubber Magnet MSDS-1

MATERIAL SAFETY DATA SHEETS RUBBER MAGNET Prepared for : XIAMEN DEXING MAGNET TECH. CO; LTD Address : UNIT 403-1, NO.992, ANLING ROAD, HULI DIST XIAMEN, CHINA EMTEK(GUANGZHOU) CO.,LTD. 1/F&4/F, BUILDING A, NO.38, NANXIANG 3RD ROAD, SCIENTECH PARK, Report Number Date of Conduct Date of Report Signed for and on behalf of EMTEK(Guangzhou) ~- (;ircvon Yan Ruixuan, Lemon Assistant engineer Sun Wei, Ethan Technical supervisor Test results are only responsible for delivered samples. This test report is issued by the company and is intended for your exclusive use. This test report includes all of the testes requested by you and the results thereof based upon the information that you provided. You have 30 days from data of issuance of this test report to notify us of any error or omission caused by our negligence. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. EMTEK ( Guangzhou ) Co., Ltd Add: 1/F&4/F, Building A, No.38, Nanxiang 3rd Road, Huangpu District, Guangzhou,Guangdong,China Http://www.emtek.com.cn E-mail: [email protected]

 Open the catalog to page 1
Rubber Magnet MSDS-2

MATERIAL SAFETY DATA SHEETS RUBBER MAGNET Product name Model Country of origin Export country CAS No. Molecular formula Rubber magnet Refer to section 3 Refer to section 3 Refer to section 3 Uses advised against : / Post code E-mail address XIAMEN DEXING MAGNET TECH. CO; LTD UNIT 403-1, NO.992, ANLING ROAD, HULI DIST. XIAMEN, CHINA Emergency phone : / Test results are only responsible for delivered samples. This test report is issued by the company and is intended for your exclusive use. This test report includes all of the testes requested by you and the results thereof based upon the information...

 Open the catalog to page 2
Rubber Magnet MSDS-3

MATERIAL SAFETY DATA SHEETS RUBBER MAGNET 2 - Hazards Identification Hazards Classification In accordance with regulation (EC) No. 1272/2008, the sample isn’t divided into dangerous article. Physical hazard Not classified as a physical hazard class. Health hazard Not classified as a health hazard class. Environment hazard Hazard pictograms Signal word Hazard statements Health hazard Environment hazard Danger of explosion Not classified as a environment hazard class. Not classified as a physical hazard. No known major effects or health hazards. No known significant effects or environmental hazards....

 Open the catalog to page 3
Rubber Magnet MSDS-4

MATERIAL SAFETY DATA SHEETS RUBBER MAGNET Substance or Preparation: Substance Note: CAS Number is Chemical Abstract Service Registry Number. EINECS Number is EUROPEAN Inventory of Existing Commercial Chemical Substance. N/A denote not applicable. Test results are only responsible for delivered samples. This test report is issued by the company and is intended for your exclusive use. This test report includes all of the testes requested by you and the results thereof based upon the information that you provided. You have 30 days from data of issuance of this test report to notify us of any error...

 Open the catalog to page 4
Rubber Magnet MSDS-5

MATERIAL SAFETY DATA SHEETS RUBBER MAGNET Consult a physician. Show this safety data sheet to the doctor in attendance. : If you feel respiratory irritation, remove to fresh air immediately. Keep the respiratory tract smooth. Use oxygen if available. Get medical aid. Skin Contact : Generally does not cause skin irritation. If you feel unwell, re-wash with plenty of water and seek medical attention immediately. Wash contaminated clothing before reuse. Eye Contact : In case of contact with eyes, rinse immediately with plenty of water for 15 minutes. Seek medical advice if irritate. Ingestion :...

 Open the catalog to page 5
Rubber Magnet MSDS-6

MATERIAL SAFETY DATA SHEETS RUBBER MAGNET 5 - Fire-Fighting Measures Extinguishing media Suitable Fire Extinguishing Media Unsuitable Fire Extinguishing Media Special hazard arising from the substance or mixture Advice for firefighters Special fire fighting procedures Use water fog, alcohol-resistant foam, dry powder or carbon dioxide to extinguish the fire. Iron oxide, carbon oxides, strontium oxide, hydrogen chloride. Protective Equipment As soon as possible, remove the goods from fire to open place. For small fires, use dry chemical, carbon dioxide, water spray or alcohol-resistant foam. For...

 Open the catalog to page 6
Rubber Magnet MSDS-7

MATERIAL SAFETY DATA SHEETS RUBBER MAGNET 6 - Accidental Release Measures Person precautions protective equipment and emergency procedures Environment precautions Methods and materials for containment and cleaning up Reference to other sections Wear suitable protective clothing, gloves and eye/face protection and self-contained breathing apparatus in pressure-demand. Evacuate all the people to safe areas. Isolate leakage area and restrict access. Ensure adequate ventilation. Avoid breathing dust/mist/vapours. Prevent to enter sewage, soil, river and sea. Sweep and shovel. Place in a suitable...

 Open the catalog to page 7
Rubber Magnet MSDS-8

MATERIAL SAFETY DATA SHEETS RUBBER MAGNET 7 - Handling and Storage Precautions for safe handing Conditions for safe storage, including any incompatibilities Specific end use(s) Keep away from sources of ignition. Operating personnel must train specially and follow close to the line of operating instruction. Ensure good ventilation/exhaustion at the workplace. Minimize vapor/aerosol generation and accumulation. Keep container tightly closed. Ventilate confined spaces before entering. Handle and open container with care. Wear suitable protective clothing, gloves and eye/face protection. Do not...

 Open the catalog to page 8
Rubber Magnet MSDS-9

MATERIAL SAFETY DATA SHEETS RUBBER MAGNET 8 - Exposure Controls / Personal Protection Control parameters Occupational exposure limits Exposure controls Monitoring Method Appropriate engineering controls Use explosion-proof ventilation equipment. Equipped with an eyewash facility and a safety shower. Use adequate general or local exhaust ventilation to keep airborne concentrations below the permissible exposure limits Personal protective equipment Respiratory Protection Body Protection Hands Protection Other Protection Self-priming respirators must be worn when the vapor concentration in the air...