video corpo

DXME-15C10 Operation manual

DXME-15C10 Operation manual
1 / 18 PagesView full catalog

DXME-15C10 Operation manual

Product catalog summary
Safety Precautions
The manual stresses the importance of reading safety instructions before using the DXME-15C10 magnetizing power equipment. Safety instructions are categorized into 'DANGER', 'WARNING', and 'CAUTION', with emphasis on preventing severe injury or death. Key measures include ensuring medical equipment is unaffected by magnetism, turning off power before wiring, and proper grounding. The equipment should not be installed in environments with dirt, oil, or corrosive gases.
General Features
The DXME series is designed for magnetizing permanent magnetic materials using capacitive pulse charge, applicable in industries like motors and home appliances. It supports high voltage and current for effective magnetization.
Specifications
The equipment operates on a single-phase AC220V power input, with a charging voltage range of DC50 - 1500V, a capacitance of 1000μF, and a maximum output current of 15000A. The charge-discharge interval is 3 seconds, and the unit weighs 150Kg.
Operation and Usage
The operation panel includes a power switch, charge voltmeter, ammeter, and indicators for charging and discharging states. It can be operated manually or automatically, requiring a well-ventilated, dust-free environment with temperatures between 10∽40℃.
Installation and Connection
Proper installation involves securely connecting the power supply and grounding wires. Detailed instructions are provided for connecting the magnetizing load and ensuring safety during operation.
Precautions and Maintenance
Regular checks and maintenance are advised to ensure correct functioning. Unauthorized repairs or modifications are warned against.
Warranty and Documentation
The document outlines the warranty period and the importance of retaining the manual for future reference, listing necessary documents for warranty claims.
Automatic Charging Method
Suitable for large volume production, this method involves connecting to a single-phase AC220V power source, pressing the power button, and setting the auto knob for automatic charging. The system enhances operational efficiency by automatically charging and discharging. If the set voltage is not reached within 10 seconds, the internal protection circuit shuts off the power to prevent damage.
Input/Output Signal
The document details input and output signals for the magnetizing power supply, including charge and discharge instructions and charge completion outputs, with each contact having a capacity of AC 125V, DC 24V, 0.5A.
Importance Notice
The magnetizing power supply requires about 10 minutes for the charging voltage to stabilize. Careful handling is crucial due to high voltages.
Precautions
The maximum charging voltage is 1500V. Incorrect handling can be dangerous. Ensure no residual charge before exchanging loads or conducting checks. The charge-discharge interval should meet technical requirements to avoid damage.
Periodical Checks
Regular checks are necessary due to high voltages. Ensure the charge voltage is 0V and the input power cable is disconnected before inspections.
Accessories
The equipment includes input and output cables, a foot switch, and necessary documentation such as an operation manual and user’s guide.
Warranty
The warranty period is one year from the date of receiving the magnetizing power, excluding failures due to user error or natural disasters.
Cautionary Notes
Ensure proper connection to a single-phase AC 220V power source, and do not connect input power to output terminals. The equipment should not be turned on without a load connected, and the front door must be closed for operation. Adjustments should be made with the residual voltage at 0V.
See more

Catalog excerpts

DXME-15C10 Operation manual-1

Capacity Type Pulse Magnetizing Power Operation manual Please carefully read this instruction manual before usage, and use the instrument according to correct method of operation. Be sure to read the “Safety” and “Cautions” before using the instrument. Carefully preserve this manual, to ensure that it will never be lost. If you have any matter unclear of encounter any trouble, etc. in the use of the instrument, do not hesitate to contact us. Xiamen Dexing Magnet

 Open the catalog to page 1
DXME-15C10 Operation manual-2

Thanks you to use our company’s capacity type pulse magnetizing power. We are committed continuously to improve product quality and development, for which we retain this right that is in this manual for product specifications and technical parameters of improvement without prior notice. We do our best to ensure the accuracy of the information in this manual, but for any errors, we do not assume any responsibility. We strive to improve product quality, while provide effective, fast technical support for customers.

 Open the catalog to page 2
DXME-15C10 Operation manual-3

CONTENTS 1 Safety Precautions ………………………………………………………………… 1 2 General ……………………………………………………………………………… 5 2-1Feature……………………………………………………………………………… 5 2-2 Instrument type and selection methods..………………………………………………5 2-3 Energy selection method………………………………………………………………5 3 Specifications …………………………………………………………………… 6 4 Method of operation and usage……………………………………………………………7 4- 1 Funct i on …… … … …… …………………………………………………… 7 4-2 Ambient requirements……………………………………………………………… 8 4-3 Installation and Connection………………………………………………………… 9 4-4 Method of operation………………………………………………………

 Open the catalog to page 3
DXME-15C10 Operation manual-4

1 Safety precautions Before using the equipment, read the following instructions without fail. When using the magnetizer power supply equipment, read the instruction manual supplied with each product thoroughly. It is also recommended to handle the equipment properly while taking adequate care for safety. Throughout discriminated by ranking as “DANGER”, “WARNING”, and “CAUTION”. In case where there is a high possibility that severe personal injury or death is caused if any safety instruction is ignored. This safety instruction is represented as ! DANGER. In case where there is a high possibility...

 Open the catalog to page 4
DXME-15C10 Operation manual-5

1-phase AC 220V and the ground connection wire(green) to the factory ground connection. • Before making wirings for the output terminal, be sure to turn off all phases of the factory power source and turn off the power circuit breaker of the equipment. • This equipment employs high voltages, and if it is handled incorrectly, it is dangerous. Before making wirings of loads (magnetizing yoke and magnetizing coil), be sure to confirm that no charge voltage remains. • Connect metal portion of the magnetizing yoke(yoke portion) and magnetizing coil(bobbin portion) to the factory ground connection....

 Open the catalog to page 5
DXME-15C10 Operation manual-6

• In the event that any abnormal operation such as malfunction of the equipment is noticed, immediately stop use of the equipment and contact us. • This equipment uses high voltages. Therefore, avoid installation in a place with much dirt, oil and fume, conductive dust, corrosive gases and/or inflammable gases, or in a place subjected to high temperature and dew formation, as it may cause this equipment to be damaged or deteriorated or to malfunction. install the equipment in a well-ventilated, less dusty and dry place. • When operating this equipment, be sure not to place around it any object...

 Open the catalog to page 6
DXME-15C10 Operation manual-7

charge and magnetic properties of the industry’s requirements, such as ferrite multi-pole permanent magnet magnetization (including radial, axial, plane, spoke to the ring), rare earth permanent magnetic materials multi-polar magnetization (including radial, axial, plane, spoke to the ring). DXME series magnetizing power, that is, high voltage, high current, capacity type discharge impulse magnetizer power. As the charge on the capacitor energy storage is sufficient, magnetizing or demagnetizing load instantaneous release (release time is typically < 100uS, depending on the load impedance parameters...

 Open the catalog to page 7
DXME-15C10 Operation manual-8

No special function 2-3 Energy selection method Capacitor discharge energy according to the formula, through the device's model number can be calculated by the energy: P = (1 / 2) * CU2 convenient to calculate a specific type of magnetizing power of the maximum discharge energy, but also can be used for selection use. For example: DXME-10C200 -6 DXME magnetizing power of the full range of products see below with the product data sheets for the selection of use. 3 Technical Specification (1)Power input

 Open the catalog to page 8

All Xiamen Dexing Magnet Tech. Co., Ltd. catalogs and technical brochures

  1. Axial Probe

    8  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.
About DirectIndustry