DX-1205F Gaussmeter
16Pages

{{requestButtons}}

Catalog excerpts

DX-1205F Gaussmeter - 1

厦门盈德兴磁电科技有限公司 Xiamen Dexing Magnet Tech. Co., Ltd The User’s Manual of DX-1205F Gaussmeter 1. Introduction 1.1 The pictures of DX-1205F Gaussmeter 1.2 Product introduction Thank you for purchasing the DX-1205F digital Gaussian meter. Please read this user manual carefully before putting the device into use. Due to continuous improvement of the product, some contents in this user manual may differ from the actual situation of the product. Any changes are subject to change without prior notice. The DX-1205F digital Gaussian meter is an optional automated interface magnetic detection device mainly used to measure the size and polarity of the surface magnetic field of permanent magnet material samples, as well as static magnetic characteristic parameters such as magnetic flux density at a certain point in space. DX-1205F digital Gaussian meter is a multifunctional, portable, and high-precision magnetic parameter Add: Unit 409, No.992, Anling Road, Huli Dist, Xiamen, China, Zip code: 361012 Tel: 86-592-5237772

Open the catalog to page 1
DX-1205F Gaussmeter - 2

厦门盈德兴磁电科技有限公司 Xiamen Dexing Magnet Tech. Co., Ltd measurement instrument. Equipped with high sensitivity and low drift Hall sensors, and applying advanced digital signal processing technology. It is very suitable for field measurement of surface magnetic field of permanent magnetic materials, surface remanence of Machine element, DC constant magnetic field, magnetic separator or separator. It can be widely used in magnetic material production and application units, measurement and testing institutions, mechanical manufacturing enterprises, university research units, etc. The Test automation...

Open the catalog to page 2
DX-1205F Gaussmeter - 3

厦门盈德兴磁电科技有限公司 Xiamen Dexing Magnet Tech. Co., Ltd 1.3 Parameters Input Power Display mode Dimension Weight Usage condition Thermal equilibrium time Test frequency Range AC 200~240V 50/60Hz 1A TFT true color LCD screen with six position display 307mmx260mmx120mm Approx 3.5kg Temperature: 0 ℃ -50 ℃; Humidity: 40% RH~85% RH 10 mins DC ±1000Gs/±3000Gs/±10000Gs /±30000GS① Gs、mT、Oe、kA/m One click switching Special function Automatic one click zero adjustment, non-linear correction Sorting function Accuracy Temperature coefficient Min.resolution Peak functions Probe sensor area Probe types Probe...

Open the catalog to page 3
DX-1205F Gaussmeter - 4

厦门盈德兴磁电科技有限公司 Xiamen Dexing Magnet Tech. Co., Ltd 2. Introduction of Hardware 2.1 Test principle When a semiconductor carrying current is in a magnetic field perpendicular to the current direction, the semiconductor will produce a transverse magnetic field List of electrical phenomena. The Hall effect refers to the generation of electromotive force in the direction perpendicular to the magnetic field and current. The Hall effect can be explained by classical electromagnetic theory. The Hall electromotive force is usually expressed as: Uh=Rh × I × B Rh is the Hall coefficient, I is the...

Open the catalog to page 4
DX-1205F Gaussmeter - 5

厦门盈德兴磁电科技有限公司 Xiamen Dexing Magnet Tech. Co., Ltd 2.2 The functions on the panel Front panel: Back panel: The RS232 definition of DX-1205F is as follows: Baud: 115200 Data bits: 8 bits Stop bit: 1 bit Check digit: None Units: There are four types of output data units, namely Gs (Gaussian), mT (Millimeter), Oe (Oster), and kA/m (Kiloampere per meter) The data format (16 characters) is shown in the following figure: Add: Unit 409, No.992, Anling Road, Huli Dist, Xiamen, China, Zip code: 361012 Tel: 86-592-5237772

Open the catalog to page 5
DX-1205F Gaussmeter - 6

厦门盈德兴磁电科技有限公司 Xiamen Dexing Magnet Tech. Co., Ltd The commonly used commands are as follows: 1. Send magnetic field test command (wait for receiving and sending magnetic field test data after sending): @ 2T# 2. Command to read real-time magnetic field value (unit: 0.01Gs): @ 3R# Definition of output automation interface for DX-1205F (a total of 9 pins): 1. 6: NC (empty pin) 2-3: Test (switch input signal, test and sort after short circuit of pin 2 and pin 3, and the short circuit time is recommended not to exceed 1 second) 4: AGND (analog output signal ground) 5: Hvol (analog output signal...

Open the catalog to page 6
DX-1205F Gaussmeter - 7

厦门盈德兴磁电科技有限公司 Xiamen Dexing Magnet Tech. Co., Ltd 2.3 Probe introduction DX-1205F standard configuration with transverse Hall probe. The probe is composed of the sensing end, scale PCB board, probe handle, cable shielding wire, DB15 core connector, and acrylic sheath. The sensing end of the probe is encapsulated with a Hall sensor, which is very fragile and fragile. The tip thickness after packaging is 1.7mm and the width is 3.5mm. The probe handle is the part where the operator holds the probe, and users can use a fixed device to hold the handle to ensure more stable measurement data. The...

Open the catalog to page 7
DX-1205F Gaussmeter - 8

厦门盈德兴磁电科技有限公司 Xiamen Dexing Magnet Tech. Co., Ltd Probe 15 core DB Sensor Area Probe scale PCB board Probe handle Cable wire Probe protection cover Add: Unit 409, No.992, Anling Road, Huli Dist, Xiamen, China, Zip code: 361012 Tel: 86-592-5237772

Open the catalog to page 8
DX-1205F Gaussmeter - 9

厦门盈德兴磁电科技有限公司 Xiamen Dexing Magnet Tech. Co., Ltd 2.4 Introduction for probe testing polarity and testing methods Standard horizontal Hall probe: When the magnetic field line enters the Hall sensor from the sensing end sealing side of the probe, the DX-1205F reading shows a symbol of+or N, and vice versa, the symbol is - or S. Place the convex side of the probe (i.e. the side with the chip sealing side) horizontally on the surface of the tested magnet or the magnetic field measurement point to measure the surface magnetism of the magnet. The correct measurement method is shown in the...

Open the catalog to page 9
DX-1205F Gaussmeter - 10

厦门盈德兴磁电科技有限公司 Xiamen Dexing Magnet Tech. Co., Ltd Longitudinal Hall probe: When the magnetic field line enters the Hall sensor from the sensing end of the probe, the DSG-510 reading shows a symbol of+or N, and vice versa, the symbol is - or S Schematic diagram of longitudinal Hall probe testing solenoid magnetic field: Place the longitudinal probe in the central area of the solenoid and perpendicular to the magnetic field line Add: Unit 409, No.992, Anling Road, Huli Dist, Xiamen, China, Zip code: 361012 Tel: 86-592-5237772

Open the catalog to page 10
DX-1205F Gaussmeter - 11

厦门盈德兴磁电科技有限公司 Xiamen Dexing Magnet Tech. Co., Ltd 2.5 The operation of keyboard 2.5.1 Zero Key 2.5.1.1 Clear the current displayed value to make comparison measurement, and compare the magnetic field data between other Test point and this state (virtual reference zero) 2.5.1.2 Place the sensing end of the probe into a zero Gaussian cavity (or other non magnetic environment) and press the Zero key to reset the device's magnetic field display. 2.5.1.3 Clear or reset the locked peak in Peak Mode, Peak Hold (peak lock cannot be cleared) 2.5.2 Unit Key Select the button to display the reading...

Open the catalog to page 11