DC Power Supply
38Pages

{{requestButtons}}

Catalog excerpts

DC Power Supply - 1

DC Power Supply DXKDP Series Programmed DC Power Supply User Manual Address: Unit 404, 4/F, No.993, Anling Road, Huli Dist., Xiamen, China. Website: https://www.dexinmag.com/ Tel: 86-592-5237772 Email: info@dexinmag.com

Open the catalog to page 1
DC Power Supply - 2

I. Safety instructions: When using this product, the following safety matters must be observed first: the cautions and warning words in the instruction manual must be understood and observed, if not, you may the safety requirements and rules for the manufacture, design and use of the product. Please note: Xiamen Dexing Magnet Tech.Co., Ltd is not responsible for accidents caused by users' non-performance of the safety rules. Symbol of high voltage warning. Symbol of High pressure hazard. Safety sign! Symbol of Body grounding. Symbol of Connecting to the earth. Warning! ▲ Operate the product...

Open the catalog to page 2
DC Power Supply - 3

▲ Please make sure that the power supply meets the requirements and the connection is correct before starting up. ▲ Please make sure that the output voltage matches the load before starting up. ▲ Do not install substitute parts on this product or make any unauthorized modifications. ▲ There are no parts inside the product that can be repaired by operators. If you need to repair by yourself, please ask the personnel who had professional training for repair. ▲ Avoid using or appearing liquid substances around the product, they may enter the inside of the product and cause product damage and...

Open the catalog to page 3
DC Power Supply - 4

The constant current mode refers to a working mode that the resistance value of the DC load changes within the rated range while the output current of the DC power supply keeps stable. That is, when the resistance value of the load changes causing the output voltage to change, the output current remains at the set current value and remains unchanged. The work mode state of the DC power supply with constant voltage/constant current mode should be determined according to the nature of the load. Under normal circumstances, the rated voltage is applied. when the actual load current value is...

Open the catalog to page 4
DC Power Supply - 5

3.5 Pulse load application The current peak value of the pulse load is within the nominal value (average value) indicated by the metering device even if it is within the rated current value range output by the DC power supply, or pulse circuit or the motor drive circuit loads the current waveform. The current will also reach the rated current area of the DC power supply, thus causing the output voltage to drop or be unstable. The solution is to connect the inductors in series between the power supply and the load, or to select a DC power supply with larger output current. If the pulse width...

Open the catalog to page 5
DC Power Supply - 6

IV. Goods inspection 4.1. Check whether the received products are consistent with the type and quantity of goods signed in the contract. If there are any errors, please do not unpack. 4.2. Please check whether there is any damage that may occur during transportation when accepting this product. 4.3. Check whether the accessories of the products are complete compared with the packing list of the products. 4.4. In case of the above-mentioned errors in product inspection, please fill in the product model, contact person's name and contact method and attach a simple explanation of the problem,...

Open the catalog to page 6
DC Power Supply - 7

higher than the voltage on the load. Therefore, the cross-sectional area of the selected conductor should meet that the potential difference is not more than 0.5V. 5.8. If multi-stage loads are connected to the same power supply at the same time, each stage load shall use a set of independent connecting wires, and be connected to the output end of the power supply respectively. 5.9. Our series DC power supplies are designed with load terminal voltage detection terminals, so the products have the function of accurately reading the load terminal voltage and conduct accurate control. When...

Open the catalog to page 7
DC Power Supply - 8

applications. The product has excellent electronic characteristics such as high accuracy, high precision and high stability. This series of products are designed with perfect overvoltage and overtemperature protection circuits, and the reliability is higher. This series of products can be programmed automatically by editing the voltage, current and time parameters with the upper computer through the panel keyboard or through the communication interface. 6.2 Product features: 1. Small volume, light weight, the standard 19-inch installation size, suitable for working table and rack...

Open the catalog to page 8
DC Power Supply - 9

7.2 Functional description of the front panel: ①、OLED display interface: displays Chinese and English menus; ②、The status indicator: -This indicator light is on when the power supply has output; -Press the "LOCK" key, the indicator light will be on, and the keyboard will be locked at this time. -The fault indicator, this indicator will be on when the machine fails or the parameters are set incorrectly; -The remote/local control indicator light, which will be on when controlled remotely; -When it is always on, it means that the DC power supply is working in constant current (or current...

Open the catalog to page 9
DC Power Supply - 10

key: the key of the lock y king keyboard When pres the key, the "lock" indi d. ss icator light is s on. All key yboards excep pt key are lock ked. key: the "C Confirm" key; ; key: the "E Exit" key; key: the "U key; Up" key: the "D Down" key. ④、The digital encoder: I can replace the keyboard for input an has the fun ④ It e d nd nction of "con nfirm key". ⑤、The pow switch: Th power inpu control sw ⑤ wer he ut witch. 7.3 Th Functiona description of rear pan he al nel: Due D to differe voltage an current sp ent nd pecifications, the input and output term d minals of the rear panel are r e rough...

Open the catalog to page 10
DC Power Supply - 11

Figure 3 ①、AC input terminal: AC input terminal of power supply, input voltage single-phase AC220V/ three-phase AC 380 V+10%; ②、"OUT+"-the positive terminal of the rear panel power output. ③、"OUT-"-the negative terminal of the rear panel power output ④、S compensation port: the detection port for power supply load end. When the user doesn't need load end detection, S1- and S- shall short circuit, and S1+ and S+ shall short circuit. When the user needs load end detection, the short circuit of S1- and S- and that of S1+ and S+ shall be removed, and then S+ is connected to the positive of the...

Open the catalog to page 11

All Xiamen Dexing Magnet Tech. Co. catalogs and technical brochures

  1. Axial Probe