YUNYI YFM4800 Wireless Split-Type Electromagnetic Flowmeter

Product catalog summary
Product Description and Features
The YFM Smart Electromagnetic Flow Meter is engineered for high performance and reliability in measuring the volume flow of conductive liquids and slurries in closed pipelines. It is suitable for industries such as steel, electricity, petroleum, and pharmaceuticals. Key features include measurements unaffected by fluid properties, no pressure loss, an easy-to-read LCD display, infrared touch button settings, bidirectional measurement, and multiple output forms including current, pulse, and frequency.
Working Principle
The flow meter operates based on Faraday's law of electromagnetic induction. It includes a measuring tube with insulating lining, electrodes, coils, and an iron core to generate a magnetic field. Conductive fluid flowing through the tube induces a voltage signal proportional to the flow rate, which is processed for display.
Technical Parameters
The device supports various power supplies (AC220V, DC24V, etc.) and has a power consumption of less than 15W. It offers analog and frequency outputs, alarm outputs, and pulse outputs with specific load resistances and current limits. The protection class is IP65, with an optional IP68 for split types, and it is explosion-proof marked.
Installation Guidelines
Proper installation is crucial for accurate measurement and longevity. The flow meter should be installed away from magnetic fields, in dry and ventilated locations, and not exposed to extreme temperatures or humidity. It should be placed at the back of pumps and not on the suction side. The sensor can be installed on various pipe orientations, ensuring full pipe flow and avoiding gas adherence to electrodes.
Instrument Wiring and Functionality
Signal cables should be short and separated from other power sources. The device supports low and high-frequency excitation, with selectable excitation currents. It features network functions like MODBUS and GPRS, and displays in multiple languages. The device records power-off times and hourly gross flux, with remote control capabilities.
Overview
This document provides detailed instructions and specifications for operating and configuring an LCD-based measurement converter. It includes key functions, parameter settings, password management, and troubleshooting guidelines.
Key Functions and Operations
  • Key Combinations: The 'Compound' key combined with 'Up' or 'Down' keys is used for navigation and adjustment. The 'Enter' key is used to access submenus or return to the main measurement mode.
  • Parameter Setting Mode: To set or correct working parameters, the converter must be in parameter setting mode, not measuring status. This involves using the 'Compound' + 'Enter' keys and entering a password.
  • Function Selection: The menu includes functions like 'Parameters Set', 'Clr Total Rec', and 'Fact Modif Rec'. Each function requires specific key combinations and passwords to access.
Parameter Settings
  • Parameter List: There are 55 parameters that can be set, including language, communication address, baud rate, sensor size, flow unit, and more.
  • Password Management: There are six grades of passwords for setting parameters, with different levels of access and modification rights.
  • Flow Parameters: Includes settings for flow range, flow response, flow direction, flow zero, and flow cutoff.
Technical Specifications
  • Communication and Sensor Options: The converter supports MODBUS communication and can be equipped with various sensors for different pipe diameters.
  • Output Options: Frequency and pulse outputs are available, with settings for analog and pulse types.
  • Alarm and Troubleshooting: The converter has self-diagnosis capabilities and can display alarms for high/low flow limits and empty pipe conditions.
Troubleshooting and Maintenance
  • Common Issues: Includes checking power supply connections, LCD contrast, and sensor connections.
  • Infrared Remote Control: The operation of the infrared remote control is similar to the instrument itself, requiring alignment and proximity for effective use.
See more

Catalog excerpts

YUNYI YFM4800 Wireless Split-Type Electromagnetic Flowmeter-1

XI'AN YUNYI INSTRUMENT COMPANY LIMITED 1.Pressure Transmi�er 4.Dead Weight Tester 7.Temperature Transmi�er 2.Pressure Guage 5. Level Transmi�er 8.Density Meter

 Open the catalog to page 1
YUNYI YFM4800 Wireless Split-Type Electromagnetic Flowmeter-2

YFM4800 ELECTROMAGNETIC FLOW METER USER MANUAL Product descrip�on YFM Smart electromagne�c flow meter is a high-performance, high-reliability flow meter. It used to measure the volume flow of conduc�ve liquid and slurry in closed pipelines. Widely used in steel, electricity, petroleum, chemical industry, coal, metallurgy, papermaking, water supply and drainage, food, pharmaceu�cal industry, etc. Working principle The measuring principle of electromagne�c flow meter is based on Faraday's law of electromagne�c induc�on. The sensor is mainly composed of a measuring tube with an insula�ng lining, a pair...

 Open the catalog to page 2
YUNYI YFM4800 Wireless Split-Type Electromagnetic Flowmeter-3

Technical parameter

 Open the catalog to page 3
YUNYI YFM4800 Wireless Split-Type Electromagnetic Flowmeter-4

Flange connection structure and installation dimensions Unit: mm Selection codes explanation Note: "•" on behalf of optional," o" is mean not optional. (1) Instrument size error ± 2mm (2) The rated flange pressure of this table DN10-DN300: 1.6MPa DN350-DN500: 1.0MPa ,DN600-DN2200: 0.6MPa. (3) Other flange standards are customized.

 Open the catalog to page 4
YUNYI YFM4800 Wireless Split-Type Electromagnetic Flowmeter-5

Flange connection structure and installation dimensions Flow range and Flow rate table Instrument installation Choosing the correct installation location and adopting the correct installation method is the key to using the electromagnetic flow meter. If the installation is wrong, Not only will it affect the measurement effect, it will also affect the measurement accuracy, it will also affect the life of the flow meter, and even damage the flow meter. Installation location selection In order to make the sensor work reliable and stable, the following requirements should be paid attention to when...

 Open the catalog to page 5
YUNYI YFM4800 Wireless Split-Type Electromagnetic Flowmeter-6

Instrument wiring ●If the signal cable connected by split installa�on uses a customized dedicated cable, the shorter the cable, the be�er. ●The excita�on cable can choose Yz medium-sized rubber sheathed cable, and its length is the same as the signal cable. ●Signal cables must be strictly separated from other power sources and cannot be laid in the same pipe. ●The signal cable and the excita�on cable should be as short as possible, and the excess cables should not be rolled together. The excess cables should be cut off, and ●Re-solder the joints. ●When the cable mediates the sensor electrical...

 Open the catalog to page 6
YUNYI YFM4800 Wireless Split-Type Electromagnetic Flowmeter-7

Plot of installing measure Fig.1 Exterior size of the integrated Circular shells exci�ng circuit Switching Power Supply 4-20mA or 0-10mA 1-5000Hz Frequencyor Pulse Output Current Output Pulse Output OC Gate Status Output Status Control Communica�on Interface Fig.2. 1 Structure Of Converter’s Circuit The converter can supply exci�ng current to the coil in the sensor of electromagne�c Flow meter,the head amplifier amplifies the electromo�ve force from the sensor and converts it into standard signals of current or frequency so that the signals can be used for displaying, controlling and processing....

 Open the catalog to page 7
YUNYI YFM4800 Wireless Split-Type Electromagnetic Flowmeter-8

Request of relative sensor Sensitivity of sensor signal: under 1m/s, output 150pV ~200pV; For electromagnetic flow meter signal converters, there are four currents of 62.5mA in exciting loop, which make up of 250mA, and every 62.5mA is controlled by one 20Q exact resistance. So user can choose different exciting current by changing the number of exact resistance. The current will be 250mA when the signal converters leave factory, as such, if there are three exact resistance, the current will be 187.5 mA; if two, 125mA; Resistance of sensor exciting coil: Digital frequency output Frequency output...

 Open the catalog to page 8
YUNYI YFM4800 Wireless Split-Type Electromagnetic Flowmeter-9

Se c � on p i c t u re of conve rs i on Key a nd d i s p l ay Squared define keys and LCD screen display C on n e c � on s of s e n sor Fig. 4.1 (c) Keys on squared panel and large LCD display: Connectors and labels for the squared Rotundity define keys and LCD screen display Fig. 4.1(d) Keys on Circular panel and big LCD display Note: When measuring, pushing down “Compound Key + Enter” will appear password of changing state, base on dis�nc�on of secrecy, and change the password as we provide. Then pushing “Compound Key + Enter” again, and you can inter the state of se�ng parameter. If want to...

 Open the catalog to page 9
YUNYI YFM4800 Wireless Split-Type Electromagnetic Flowmeter-10

Labels of connectors in squared model Links and labels of connectors in Circular Model SIG 1 Signal 1 SGND Signal Ground SIG2 Signal 2 DS1 Shielded Exciting 1 DS2 Shielded Exciting2 EXT + Exciting Current + VDIN Current Two lines 24 V Spots ICOUT Analog Current Output ICCOM Analog Current Output Ground _ POUT Flow Frequency ( Pulse)Output PCOM Frequency (Pulsc)Output Ground ALMH Upper Limit Alarm Output ALM L Low Limit Alarm Output ALCOM Alarm Output Ground _ TCOM 232 Communication Ground To Separate Model Sensor Analog Current Output Frequency (Pulse) Output Communication Input Signal lines...

 Open the catalog to page 10
YUNYI YFM4800 Wireless Split-Type Electromagnetic Flowmeter-11

Labels and connec�on of signal lines in Circular model Output and power line All cables for signals transferring and power supply must be prepared by users. However, it should be careful to choose the cables that meet the upper limit load of consuming current. Note: When DIP switch next to terminal is set to ON places, the converter from its inside can provide +28Vpower supply and up-pull 10kΩ resistance to output Frequencies (PUL) to isolated OC gate, Alarm Output (ALMH.ALML), and Status Control ( INSW).Therefore, when converter has frequency output and works with sensor together, DIP switch...

 Open the catalog to page 11
YUNYI YFM4800 Wireless Split-Type Electromagnetic Flowmeter-12

The grounding requirements when installing convert Contact area of copper Connector PE on Converter Cabinet for grounding should be larger than 1.6mm2.Contact resistance should be less than 10Ω. First, purple copper tube should be cut into 1700 mm long (the copper tube can be lengthened according to the need ) to make the nail buried 1500 mm into the ground(Note : when burying nail, sprinkling a layer of broken charcoal at the top of nail, and then saline irriga�on). Then, 4 mm2 purple copper wire should be welded to the nail. At last, connec�ng ground wire to convert’s flange, ground ring and...

 Open the catalog to page 12

All Xi'an Yunyi Instrument Co., Ltd. catalogs and technical brochures

  1. K series

    3  Pages

  2. YX-2006B

    2  Pages

  3. XY-2002

    1  Page

  4. YFM4800E

    14  Pages

  5. YD32

    2  Pages

  6. YD31 series

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.