1. Catalogs
  2. Xi'an Yunyi Instrument Co., Ltd.
  3. YUNYI Wireless Gas Turbine Flow Meter

YUNYI Wireless Gas Turbine Flow Meter

YUNYI Wireless Gas Turbine Flow Meter
1 / 18 PagesView full catalog

YUNYI Wireless Gas Turbine Flow Meter

Product catalog summary
Summary:
The LWQ gas turbine flow meter is a precision instrument for measuring single-phase gas in industries like city gas, petroleum, and chemicals. It performs well in various pressure environments and can be customized for different accuracy levels.
Leading Features:
- High accuracy and repeatability with a wide range ratio up to 1:20.
- Integrated rectifier requiring minimal straight pipe sections.
- 360° rotatable volume regulator for easy reading.
- Low speed, high life, low pressure loss, and high precision.
- Equipped with high-precision digital sensors for temperature and pressure with compensation and correction functions.
- Advanced low power consumption technology with large data storage and tamper-proof features.
- Capable of wireless communication via GPRS or NB-IOT modules.
Operational Principle:
The turbine flowmeter operates by rectifying and accelerating fluid flow, generating rotational torque on the turbine. The angular velocity of the turbine is proportional to the fluid volume flow rate. It uses electromagnetic induction to sense pulse signals, which are processed for display.
Technical Performance Indicators:
- Complies with various national and enterprise standards.
- Accuracy levels of 1.0 and 1.5 with specific error margins for temperature and pressure.
- Electrical performance includes internal and external power supply options, low power consumption, and various input/output signal capabilities.
- Wireless communication options for remote data transmission.
Overall Dimensions and Installation:
- Designed for flange connection and should be installed in environments free from strong magnetic fields and mechanical vibrations. Suitable for horizontal installation and should be protected from environmental elements when installed outdoors.
Use and Setting-Up:
- Detailed instructions on setting up and using the flowmeter are provided, ensuring optimal performance and longevity.
Lubrication and Maintenance:
- Regular maintenance and lubrication are necessary to ensure the flowmeter's accuracy and reliability.
Packaging, Transportation, and Storage:
- Guidelines for proper packaging, transportation, and storage to prevent damage and ensure the flowmeter's integrity.
Unpacking and Inspection:
- Instructions for safely unpacking and inspecting the flowmeter upon delivery.
Order Instructions:
- Details on how to place orders for the flowmeter, including customization options.
Installation Guidelines:
Ensure a straight pipe length of 2 DN upstream and 1 DN downstream of the flowmeter. A bypass pipe can be installed with a locked valve for normal use. Install a filter upstream (2 DN) to match specifications. Consider telescopic or corrugated pipes to minimize deformation from pipeline stress. The flowmeter must be coaxial with the pipe, and sealing gaskets should not enter the pipe cavity. Ground the flowmeter reliably, but do not share the ground line with the system or welding system.
Operational Warnings:
Do not change the explosion-proof system connection mode arbitrarily. Open the valve slowly when starting operation to avoid turbine damage. For remote signal transmission, use a +24 VDC power supply and avoid direct access to 220 VAC or 380 VAC. Do not weld directly at the flowmeter inlet flange. Purge pipelines before installation to remove debris.
Environmental and Fluid Conditions:
Ambient temperature: -25℃ to +55℃, Relative humidity: 5% to 95%, Medium temperature: -20℃ to +80℃, Atmospheric pressure: 86 kPa to 106 kPa. The fluid should be a single-phase gas without large particles or impurities.
Battery and Reading Instructions:
Monitor battery power level and replace when necessary. The flowmeter reading is displayed on an LCD screen, and the volume modifier can be rotated for easy reading.
Maintenance and Safety:
Regular lubrication is required for stainless steel bearings. Refuel 3-4 times a year based on usage conditions. Ensure the flowmeter operates within specified flow ranges to prevent damage. Install filters to prevent debris from affecting the flowmeter.
Packaging and Storage:
Flowmeters should be packed in firm wooden boxes and stored in conditions free from mechanical vibration, with a temperature range of 5℃ to 40℃ and relative humidity not exceeding 90%.
Ordering Instructions:
Specify the nominal pressure, medium temperature, flow range, and environmental conditions when ordering. Choose the appropriate electronic watch head based on needs.
See more

Catalog excerpts

YUNYI Wireless Gas Turbine Flow Meter-1

YFT400IC Gas turbine flow meter User manual Please read the user manual carefully before using the product

 Open the catalog to page 1
YUNYI Wireless Gas Turbine Flow Meter-3

The LWQ gas turbine flow meter is a precision measuring instrument with high precision and high reliability.Suitable for all kinds of single-phase gas measurement, used in the city gas, petroleum , chemical,electric power, metallurgy and other industries gas measurement. LWQ gas turbine flow meter has excellent low pressure and high pressure metering performance, suitable for measuring accurate measurement of large flow gas. According to the user needs,our company can provide different accuracy levels, different performance of the turbine flow meter. 2. leading feature ◆ High accuracy, good repeatability,...

 Open the catalog to page 3
YUNYI Wireless Gas Turbine Flow Meter-4

1: Display 2: volume modifier 3: flow meter housing 4: oil pump 5: output air insert 6: front guide fluid Figure 1. Schematic diagram of the turbine flow meter structure 3.2. Mechanical counter with low-frequency signal output The turbine rotates , reduced by gears , magnetically coupled to the mechanical head. The digital wheel is displayed as the total working volume , the counter can be equipped with low signal output unit , can be connected to the volume modifier or user equipment. 3.3. Working principle of the volume modifier The volume modifier is composed of temperature and pressure detection...

 Open the catalog to page 4
YUNYI Wireless Gas Turbine Flow Meter-5

(For natural gas compression factor, calculated according to CNPC NX-19 standard); Zn-is the gas compression coefficient under the standard stat Zg-is the gas compression coefficient in the working state. A. WT series gas turbine flow meter performs JJG1037-2008 Turbine flowmeter verification procedure B. Implement Q / WD 003-2020 WTEI Gas Turbine Flowmeter enterprise standard Implement Q / WD 0052020 WTD Gas Turbine Flowmeter enterprise standard C. Implement GB / T18940-2003 / ISO995 1: 1993 National standard for measuring turbine Flow meters in closed pipeline D. Implement GB / T28848-2012...

 Open the catalog to page 5
YUNYI Wireless Gas Turbine Flow Meter-6

◆ Pulse signal (three-line system) : the pulse signal detected by the flow sensor is directly amplified and output through optical coupling isolation , and the maximum amplitude value is about (V -2) V (V V outside the external power supply) , the transmission distance is 50m , and operated by the external power supply. ◆ (4~20) mA standard analog signal: (4~20) mA standard analog signal linearly corresponds to (O ~ Qmax) m3 / h standard volume flow , the flow range can be set according to the parameters in the instrument , the transmission distance is 200m , the wiring mode is two or three wire...

 Open the catalog to page 6
YUNYI Wireless Gas Turbine Flow Meter-7

4.3.6 Product safety parameters are shown in Table 1 power supply

 Open the catalog to page 7
YUNYI Wireless Gas Turbine Flow Meter-8

PLo 、V- Calibration/pu J2 3 _ lse/Chong output 、J2-4) 、 Battery under GND ( pressure J3_ 3 、 alarm J3-1) BJ Certain pulse Chong output Flow onThe GND lower limit Police J3(4_ output 、J3-1) Table 1 4.4. Mechanical performance indexes 4.4. 1 See Table 2 for the model specifications and basic parameters in t

 Open the catalog to page 8
YUNYI Wireless Gas Turbine Flow Meter-9

impeller material stainless steel Shell material: Carbon steel or stainless steel Shell material: Note: The flow range listed in Table ① is the flow range of the product during the factory verification (the medium under normal temperature and normal pressure is air) ; ② As the pressure increases , the flow range also expands . 4.4 .2 Typical characteristic curve The typical characteristic curve of the flowmeter is shown in Figure 3. Y coordinate represents the basic error of the instrument , and X coordinate represents the percentage of the maximum flow rate of the meter . (%) 3

 Open the catalog to page 9
YUNYI Wireless Gas Turbine Flow Meter-10

4.4 .3 Pressure loss of the flowmeter The pressure loss of the turbine flowmeter is related to the drive of the turbine , the friction inside the pipe and the speed and direction of the fluid , and the turbine is in working conditions The lower pressure loss can be obtained by using the following equation: Where: under Δ P Q max— — standard state, the pressure loss of the maximum flow rate (kPa) when the medium is dry air (20℃, 101.325 kPa, ρ = 1.205 kg/m3);

 Open the catalog to page 10
YUNYI Wireless Gas Turbine Flow Meter-11

Dielectric density (kg/ m 3) ; Pa —— local The gauge pressure of Pg —— (kPa); P 0 — — Standard atmospheric pressure ( 1 0 1 . 3 2 5 kPa) ; Absolute temperature ( 2 9 3 . 1 5 K ) in the T0 — — standard state; Absolute temperature (273. 15+t) K; Q —— operating flow (m 3 / h) ; Qmax —— instrument (m 3 / h). 4.5. Explosion-proof type and grade Explosion-proof type of flowmeter: the explosion-proof grade is Exib Ⅱ BT 3 Gb. 4.6. Protection grade: IP 65 5. Overall dimensions and installation 5.1. Overall dimensions The external dimension of the flowmeter is shown in Figure 5 . The indicated dimensions...

 Open the catalog to page 11
YUNYI Wireless Gas Turbine Flow Meter-12

♦ There shall be no strong external magnetic field interference and strong mechanical vibration around the flowmeter. Before installation, the environmental conditions should be reviewed according to the use requirements for normal use. ♦ Flow meter should not be used in the flow of frequent changes and strong pulsation flow or pressure pulsation occasions. ♦ When the flow meter is installed outdoors, the upper part should be covered to prevent the rain immersion and the scorching sun and affecting the service life of the flow meter. ♦ The flowmeter is suitable for horizontal installation, and...

 Open the catalog to page 12
YUNYI Wireless Gas Turbine Flow Meter-13

◆ The flowmeter must be grounded reliably as specified , but shall not share with the ground line of the system and the welding system during pipe installation or maintenance . ◆ Du ri ng th e use pro c e s s , use rs sha ll not cha nge the conne c ti on mode of the ex p l o s i o n - p r o o f sy s t e m an d ch a n g e th e le a d in t e r f a c e ar b i t r a r i l y , an d sh a l l st r i c tl y fol low it if nec es sa ry GB3836.1 Relevant requirements of the 1 ~ 2 for operation. ◆ When the flowmeter is put into operation , the valve should be opened slowly (the opening time is not less than...

 Open the catalog to page 13
YUNYI Wireless Gas Turbine Flow Meter-14

Open the front cover of the volume modifier, remove the old battery, install the new battery (12 # 3. 6V lithium battery) according to the polarity mark in the battery box, and finally install the back cover of the modifier. 6.7. 1 The relevant measurement parameters of the flowmeter are displayed on the LCD screen of the volume modifier, which can realize the direct flow measurement reading. 6.7 .2 The primary meter of the flowmeter and the volume modifier adopt a special connection structure. When the flowmeter affects the normal reading due to the installation environment restrictions, the...

 Open the catalog to page 14