MH-NA Level Measuring Instrument User Manual
Open the catalog to page 1
Ⅳ、MENU OPERATION AND PARAMETERS SETTING
Open the catalog to page 2
MH-A ultrasonic level measuring instrument, taking the advantages of various many level measuring instruments, is a universal one characterized by total digitalized and humanized design. It has perfect level monitoring, data transmission and man-machine communication. It is featured by strong anti-interference performance; free setting of upper and lower limits and online output regulation, on-site indication, optional analog, switching value, and RS485 output and easy connection with main unit. The cover, made of waterproof engineering plastics, is small and firm with ABS probe. Therefore,...
Open the catalog to page 3
Power: 12-24VDC Power consumption:<1.5W Output (optional): 4~20mA RL>600Ω(standard) 1~5V\1~10V RS485 3 NPN 2 relays (AC: 5A 250V DC: 10A 24V) Material:ABS Dimension:Φ92mm×198mm×M60 Electrical interface:M20X1.5 Installation:M60X2 or ¢61MM Operating surroundings:normal temperature, normal pressure Protection degree:IP65(others optional) IV. Menu operation and parameters setting 4.1 Keys function (A) (1.1)normal work / menu:enter password. (1.2)menu interface:page down or back, Long press back to normal work. (1.3)input/ confirm: Confirm input data and exit this menu. (B) (2.1)menu interface:...
Open the catalog to page 4
FS.45:FS,end point of output:20mA. DR.49:Add.,serial port address: 0-255. BP.50:Bdr.,serial port baud rate: 600-38400. 1L.54:No.1 D,No.1 switch output D. 1H.55:No.1 H,No.1 switch output H. 2L.56:No. 2 D,No.2 switch output D. 2H.57:No.2 H,No.2 switch output H. 3L.58:No.3 D,No.3 switch output D. 3H.59:No.3 H,No.3 switch output H. Ⅴ、Installation and precaution 5.1 sensor installation 5.1.1 Sensor should be placed where there is no obstacle between emission surfaces and measured liquid, it also should be far way from feeding throats, chartⅠ. 5.1.2 Tank shape should be considered. Some type of...
Open the catalog to page 5
5.2 work mode This instrument has two mode, the difference as following, chart V: 5. 2.1 Measure liquid level B (Installation Height) is the distance from bottom of container to sensor surface, A is the distance between sensor surface and liquid surface, D is the height oi liquid, D= B (Installation Height) -A, display value is bottom of container to liquid surface (D) . 5. 2. 2 Measure air distance Set BD =0, display value is distance from sensor surface to liquid surface (A). 5.3 DC12V power is better. When it’s from switch power, the DC negative must contact ground. Refer to the tags...
Open the catalog to page 6
6.2 Wiring diagram of current (voltage) output connecting with secondary instrument Level meter Secondary instrument Input ﹢(3 wire for power ﹢) 6.3 serial output connecting with PC Power Level meter Supply + Output A Output Serial port 6.4 NPN output wiring diagram Conventional relay
Open the catalog to page 7
©Non vertical installation, leading to multiple reflection ©installed too close to wall, sonic wave reflected midway© check “BD”@ check temperature display Remedy ©Adjust installation positions several times.© correctly set “BD” ©adjust temperature (“TE”) to proper value. 6 Abnormal current output Probable reason ©Too large load resistance ©FS, AL or AH changed. © undesired supply rectification and filtering @ electrify time is not enough Remedy ©Lower load resistance ©readjust parameter© replace with DC regulated supply with larger capacity ©electrify >15 minutes before work 7^ Abnormal...
Open the catalog to page 9
Manufacturer Certificate Mode Main specification Sense range:FS= Output:□0-20mA;■4-20mA;□0-5V;□1-5V; □ 0-10V;□1-10V;■RS485;□other Working temperature:■normal;□-10-60℃;□other Working pressure:■normal;□other Working humidity:≤80%RH Storage temperature:-40—85℃ Storage humidity:≤70%RH Working
Open the catalog to page 10All Xi'an Yunyi Instrument Co. catalogs and technical brochures
-
K series
3 Pages
-
YX-2006B
2 Pages
-
XY-2002
1 Pages
-
YFM4800E
14 Pages
-
YD32
2 Pages
-
Temperature calibrator WT
2 Pages
-
Pt100 temperature sensor
3 Pages
-
Digital density meter JL-T
6 Pages
-
Process density sensor
8 Pages
-
Digital density meter YMF883
4 Pages
-
Digital density meter JL-YT
4 Pages
-
Digital density meter JL-LD
2 Pages
-
Digital density meter JL-SD
2 Pages
-
Digital density meter JL-GD
2 Pages
-
Portable pH meter K series
2 Pages
-
Leak calibrator XY-2006B
2 Pages
-
Deadweight tester JY
2 Pages
-
Pressure calibrator XY-2001A
2 Pages
-
Pressure calibrator YX-60
2 Pages
-
Leak calibrator YX-2001C
2 Pages
-
Dial pressure gauge YK-M4
2 Pages
-
Infrared flow meter YFM-4800
21 Pages
-
Mass flow meter YFU2000-B
4 Pages
-
Mass flow meter Coriolis
14 Pages
-
Orifice flow meter
6 Pages
-
Mass flow meter MF4000
3 Pages
-
Mass flow meter
3 Pages
-
Vortex flow meter YFV
20 Pages
-
Ultrasonic flow meter YFU2000H
14 Pages
-
Turbine flow meter YFT
13 Pages
-
Mass flow meter YFV300
20 Pages
-
Mass flow meter YFT300D
13 Pages
-
Turbine flow meter
13 Pages
-
Mass flow meter MF5700
3 Pages
-
Liquids level gauge UHZ-10
1 Pages
-
Level measuring instrument
11 Pages
-
Liquids level gauge YLR68
12 Pages
-
Liquids level gauge
3 Pages
-
Radar level sensor
12 Pages
-
Diaphragm pressure switch
2 Pages
-
Digital pressure controller
2 Pages
-
YD31 series
4 Pages