Catalog excerpts
XI'AN YUNYI INSTRUMENT COMPANY LIMITED 1.Pressure Transmi�er 4.Dead Weight Tester 7.Temperature Transmi�er 2.Pressure Guage 5. Level Transmi�er 8.Density Meter
Open the catalog to page 1Product overview Instrument Introduc�on Sensor is 26G High Frequency radar level measurement instrument, measure the maximum distance to 70 meters. Antenna being further op�mized, fast new microprocessor could be higher-speed signals processing, makes the instrument can be used in reactors, solid-state storage bin and some complicated measuring condi�ons. YLR806A1 Applica�on: All kinds of corrosive liquids Measurement Span:0 to 20 meters Process Connec�on: Thread or Flanges Radar antenna send narrow microwave pulses and pass antenna transfer downward. Microwaves reflected back into contact...
Open the catalog to page 2YLR806A5 Applica�on: It is suitable for monitoring the water level of lakes, river courses, reservoirs, open channels, �dal water level, water level of Bridges, and water level in low-lying areas of ci�es. Features: high precision; Strong an�-interference ability, not affected by temperature, humidity and wind power; Simple installa�on and debugging; Low power consump�on. Measurement Span: 0 to 70 meters Process Connec�on: PP/Stainless steel Bracket Medium Temperature Span: -40~100℃ Process Pressure: -1Bar~1 Bar Accuracy: -1Bar~1 Bar Proof Grade: IP67 Supply: DC24V (RS485 is 6-24Vdc supply)...
Open the catalog to page 3The Installa�on Requirements Installa�on Guide Tapered tank cannot be installed on the top of the feeding mouth. TAlso note: outdoor installa�on should be taken sunshade, Rainproof measures. Installed in the 1/4 or 1/6 diameter of tank. Note: the minimum distance from the tank wall should be tank high 1/10. Note: ① base level ②Container central or axis of symmetry ① Right The instrument cannot be installed in the middle of an arch or a circular tank top. In addi�on to produce indirect echo is also affected by the echoes. Mul�ple echo can be larger than the true value of signal echo, because...
Open the catalog to page 4Electronic Connec�on Power Supply (4~20) mA/HART(2 wires)The power supply and the output current signal sharing a two core shield cable. The specific power supply voltage range of see technical data. For intrinsically safe type must be added a safety barrier between the power supply and the instrument. (4~20) mA/HART(4 wires)Separate power supply and current signals, respec�vely using a cable.The specific power supply voltage range of see technical data. RS485/Modbus Power supply and Modbus signal lines separated respec�vely using a shielded cable, the specific power supply voltage range of...
Open the catalog to page 5Instrument Commissioning Three kinds of debugging method: Display / key PC debugging HART handheld programmer By showing the 4 bu�ons on the screen of the instrument for debugging. Debug menu languages. A�er debugging, generally used only for display, through the glass window can be clearly read measured value. The Structure Size, Unit: mm Housing: Display/Keys ①LCD display ② Keys YLR806A2 Connected with the host computer through the HAR ①The RS232 interface or USB interface ②The radar level meter ③ The HART adapter ④ The 250 resistor YLR806A2 HART handheld programmer ① The HART handheld...
Open the catalog to page 6Installa�on Drawing: Installa�on Drawing:
Open the catalog to page 7Installa�on Drawing: Installa�on Drawing:
Open the catalog to page 8Installa�on Drawing: Flange Selec�on:
Open the catalog to page 9Linear Instruments The seal between the shell and the shell cover YLR806A2 YLR806A3 Emission angle 20° Accuracy sees below picture
Open the catalog to page 10Instrument Model Codes Selection Table Emission angle - 0 196mm -0242mm Accuracy Depending on the size of the antenna 4° 4° sees below picture Depending on the size of the antenna 12° 8° 6° Principle Type P Standard Type (Non explosion proof) I Intrinsic safety type (Exib IIC T6 Gb) D Flameproof and Intrinsic safety types (Exd [ib] /Exib IIC T6 Gb) Antenna type / materials F Sealing horn / PTFE (-40~120"C) Process connection / materials G Thread G1/ A Electronic Output 2 (4~20)mA/24V DC 2 wires Emission angle -046mm -076mm -096mm Accuracy Depending on the size of the antenna 18° 12° 8°
Open the catalog to page 11YLR806A2 Type P Standard Type (Non explosion proof) I Intrinsic safety type (Exib IIC T6 Gb) D Flameproof and Intrinsic safety types (Exd [ib] /Exib IIC T6 Gb) Process connection / materials G Thread G1]4 A/Stainless Steel 304 N Thread 1]4 NPT/Stainless Steel 304 A Flange DN50/Stainless Steel 304 Antenna type / materials A Horn antenna 046mm/Stainless Steel 304 B Horn antenna 076mm/Stainless Steel 304 C Horn antenna 096mm/Stainless Steel 304 Y Specially Customized Sealing/Process Temp V Common Sealing/ (-40~150) C K High Temp Sealing/ (-40~250) C Electronic Output 2 (4~20)mA/24V DC 2 wires...
Open the catalog to page 12— = YLR806A5 Type A2 30M Range Type A5 70M Solar Power Type Process connection / materials Z Steel Bracket G Thread G1]4 A/Stainless Steel 304 N Thread 1]4 NPT/Stainless Steel 304 A Flange DN50/PP Antenna type / materials A Horn antenna 076mm/Stainless Steel 304 B Horn antenna 096mm/Stainless Steel 304 C Horn antenna 0121mm/Stainless Steel 304 Sealing/Process Temp V Common Sealing/ (-40~100) C Electronic Output 2 (4~20)mA/24V DC2 wires Housing/ Proof Grade L Aluminum/IP67 Cable Conduit Port YLR806A6 Type P Standard Type (Non explosion proof) I Intrinsic safety type (Exib IIC T6 Gb) D...
Open the catalog to page 13Customers Info Register Company name: Address: Tel: E-mail: Type □ Intrinsic safety Type (Exib IIB T5) □ Intrinsic safety Type (Exib IIC T6 Gb) □ Standard Type (Non explosion proof) □ Intrinsic safety Type + Marine Type (Exib IIC T6 Gb) □ Flameproof and Intrinsic safety types (Exd [ ib ] IIC T6 Gb) Tank / container information Process Connection Thread :(□ G14A □ 14NPT ) Flange (DN= Power Supply: Contact name: Post Code: Fax: Date: Year Tank / container Type: □ Storage tank □ Reaction tank □ Separation tank □ Marine tank Tank structure: Dimension: Material: Top of tank: Bottom of tank...
Open the catalog to page 14All Xi'an Yunyi Instrument Co. catalogs and technical brochures
-
K series
3 Pages
-
YX-2006B
2 Pages
-
XY-2002
1 Pages
-
YFM4800E
14 Pages
-
YD32
2 Pages
-
Temperature calibrator WT
2 Pages
-
Pt100 temperature sensor
3 Pages
-
Digital density meter JL-T
6 Pages
-
Process density sensor
8 Pages
-
Digital density meter YMF883
4 Pages
-
Digital density meter JL-YT
4 Pages
-
Digital density meter JL-LD
2 Pages
-
Digital density meter JL-SD
2 Pages
-
Digital density meter JL-GD
2 Pages
-
Portable pH meter K series
2 Pages
-
Leak calibrator XY-2006B
2 Pages
-
Deadweight tester JY
2 Pages
-
Pressure calibrator XY-2001A
2 Pages
-
Pressure calibrator YX-60
2 Pages
-
Leak calibrator YX-2001C
2 Pages
-
Dial pressure gauge YK-M4
2 Pages
-
Infrared flow meter YFM-4800
21 Pages
-
Vortex flow meter YFV
20 Pages
-
Mass flow meter YFU2000-B
4 Pages
-
Mass flow meter Coriolis
14 Pages
-
Orifice flow meter
6 Pages
-
Mass flow meter MF4000
3 Pages
-
Mass flow meter
3 Pages
-
Vortex flow meter YFV
20 Pages
-
Ultrasonic flow meter YFU2000H
14 Pages
-
Turbine flow meter YFT
13 Pages
-
Mass flow meter YFV300
20 Pages
-
Mass flow meter YFT300D
13 Pages
-
Turbine flow meter
13 Pages
-
Mass flow meter MF5700
3 Pages
-
Liquids level gauge UHZ-10
1 Pages
-
Level measuring instrument
11 Pages
-
Liquids level gauge YLR68
12 Pages
-
Liquids level gauge
3 Pages
-
Radar level sensor
12 Pages
-
Diaphragm pressure switch
2 Pages
-
Digital pressure controller
2 Pages
-
YD31 series
4 Pages