1. Catalogs
  2. Xi'an Yunyi Instrument Co., Ltd.
  3. Electromagnetic flow meter YFM3800

Electromagnetic flow meter YFM3800

Electromagnetic flow meter YFM3800

Electromagnetic flow meter YFM3800

Product catalog summary
Overview: The document provides technical specifications and installation guidelines for the YUN YI Insertion Electromagnetic Flow Meter, model YFM3800, designed for measuring conductive liquids in large diameter pipes.
Main Specifications:
  • Pipe Size: Suitable for DN300 to DN3000mm.
  • Operating Pressure: Less than 1.6 Mpa.
  • Medium Temperature: 0°C to 70°C.
  • Flow Range: 0.01 m/s to 10 m/s.
  • Power Consumption: Less than 20 W.
  • Protection Grade: IP68.
  • Connection Method: Flange or Thread with materials like 304, 316L, Hastelloy alloy, Titanium, etc.
  • Accuracy: ±2.5%.
  • Communication Protocols: Modbus (RS485/RS232), Hart.
  • Power Supply: 220VAC, 24VDC/12VDC, 3.6VDC.
  • Signal Output: 4-20mA, pulse, frequency.
Key Features:
  • Simple and robust structure with no moving parts, ensuring long service life.
  • Strong anti-interference capabilities for reliable measurement.
  • Compact and lightweight design for easy installation.
  • Wide measurement range and cost-effective installation, especially for large diameter pipes.
Installation Guidelines:
  • The installation position should be fully submerged in liquid.
  • Ensure easy measurement of the pipeline's internal diameter or perimeter with minimal ovality.
  • Maintain a straight pipe length of more than 10D upstream and more than 5D downstream, where D is the pipeline diameter.
  • Vertical installation is recommended, with the sensor aligned vertically with the axis and an angle of less than 5° with the cross-section.
  • Two sensor insertion methods: 1/4 or 1/2 of the pipe inner diameter.
  • Correctly weld the installed base on the pipeline and clean any welding slag.
  • Turn off the flow control valve or use low water supply pressure during installation.
Ordering Information: The document provides a selection guide for ordering, including options for diameter, structure, electrode material, power supply, output signal, communication protocol, and installation type.
Data Summary: A table compares common pipe inner diameters with average flow rates and volume flow rates, providing a quick reference for expected performance across different pipe sizes.
See more

Catalog excerpts

Electromagnetic flow meter YFM3800-1

XI'AN YUNYI INSTRUMENT COMPANY LIMITED 1.Pressure Transmi�er 4.Dead Weight Tester 7.Temperature Transmi�er 2.Pressure Guage 5. Level Transmi�er 8.Density Meter

 Open the catalog to page 1
Electromagnetic flow meter YFM3800-2

Main specification Flow sensor Seeing and loOung mechanism i Figure 1 Sensor with ball valve overall structure diagram Sealing and locking mecharwn | Figure 2 Sensor without ball valve overall structure diagram YUN YI Insertion electromagnetic flow meter is composed of insertion electromagnetic sensor and electromagnetic flow converter, used to measure the conductive liquid that electrical conductivity is greater than 5 us/cm , it is used to measure the water, sewage, acid, alkali and other medium. Suitable for measuring the large pipe of diameter DN300~DN3000mm,. Installation can be divided...

 Open the catalog to page 2
Electromagnetic flow meter YFM3800-3

Electronic Connections l.The installaton position should be full of liquid. 2.The internal diameter or perimeter of pipeline should be measured easily, and ovality should be small. 3.The length of straight pipe on upstream should be more than 10D, and downstream should be more than 5D, D is the diameter of pipeline. 4.Vertical installation, the sensor should be vertical with axis, the included angle with cross section should be less than 5°. 5.There are two ways to insert the sensor: 1/4 of the pipe inner diameter or 1/2 of the pipe inner diameter. 6.Weld the installed base on pipeline correctly,...

 Open the catalog to page 3

All Xi'an Yunyi Instrument Co., Ltd. catalogs and technical brochures

  1. K series

    3  Pages

  2. YX-2006B

    2  Pages

  3. XY-2002

    1  Page

  4. YFM4800E

    14  Pages

  5. YD32

    2  Pages

  6. YD31 series

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.