CS-PT624 Electronic Pressure SwitchCS-PT624 Applications • General industrial applications The model CS-PT624 pressure switch for general purpose is the ideal solution for general industrial applications. These measuring ranges can be combined in almost any way with relay output signal. When the pressure is higher than the alarm pressure point (at the case of high alarm), the LED turns on, and NO port is connected to COM port, NC port is isolated from COM port; and this situation will be kept, till the pressure is lower than the release pressure point. Furthermore, it offers three options for the accuracy 0.5 % F.S, 0.25% and 1 %F.S. All variants described in this data sheet are available on very short lead times. For particularly urgent demands, there is a sizeable stock available. • SS304 Shell and Pressure Connector • Relay Output • Over-voltage protected • Reverse voltage protected • Alarm Pressure can be Adjusted from 0 to Full
Open the catalog to page 1CS-PT624 Electronic Pressure SwitchPerformance Specifications Temperature: 25 °C ; Power supply: 12VDC(or 24VDC, if the range of power supply does not include 12VDC ); Relative humidity: 45%~75%; Ambient atmospheric pressure: 86KPa-106KPa.
Open the catalog to page 2Electrical Connection Connection
Open the catalog to page 3CS-PT624 Electronic Pressure Switch As shown above, the power supply 1 and 2 can be a same one, also can be unrelated. The power supply 1 is the power supply for this pressure switch. The power supply 2 is the power supply for the load, it should not exceed DC24V (or AC120V). The connection mode of the load is shown as R1 (or R2) in the figure. If the load requires the direction of the power supply (as current voltage), please follow the corresponding requirement. Switching Mode Return Stroke Error = | Action Pressure - Release Pressure | Adjust Turn left to release the screw above the adjusting...
Open the catalog to page 4CS-PT624 Electronic Pressure Switch Ordering Guide PT624 Electronic Pressure Switch
Open the catalog to page 5CS-PT624 Electronic Pressure SwitchNotes 1. Only use the pressure switch to test the medium which have no corrosion to its housing and seal material. 2. Cannot use sharp tools to clean the pressure hole when the hole of the pressure switch is blocked. The pressure switch shall be removed from system and put the pressure hole part into the fluid which can dissolve the blocking substance. 3. The switch should be installed in locations where they are not easily to be impacted or trampled. 4. Use beyond the overload pressure of the switch may cause damages. 5. In order to protect the transmitter...
Open the catalog to page 69 Pages
7 Pages
7 Pages
6 Pages
5 Pages
6 Pages
5 Pages
6 Pages
5 Pages
6 Pages
6 Pages
6 Pages
4 Pages
5 Pages
6 Pages
8 Pages
7 Pages
9 Pages
8 Pages
1 Page
1 Page
1 Page
2 Pages
2 Pages
2 Pages
1 Page
1 Page
1 Page
1 Page