CS-PT300G Series Pressure Transmitter Applications • Cold water screw unit • Water source heat pump unit • Ground source heat pump unit • Industrial refrigeration unit • Precision computer room air conditioning • Interrow refrigeration air conditioning • Air source heat pump PT300G pressure transmitter for refrigeration with fully welded structure is widely used in air conditioning, refrigeration and heat pump systems. Industry standard 4~20mA or 0.5~4.5V signal output, international electrical connectors and pressure ports, all-welded structure, anti-condensation, suitable for refrigerant pressure measurement. This product allows to control and ensure that the system operates under safe and stable conditions. • Sealed Gage • All welded construction, no O-rings, no leakage risk • Anti-condensation water • Forward and reverse overvoltage • High precision
Open the catalog to page 1CS-PT300G Series Pressure Transmitter Performance Specifications Temperature:20~25℃; Power supply:12VDC (4~20mA),5VDC(0.5~4.5VDC Ratio );Relative humidity:45%~75%; ambient atmospheric pressure:86KPa~106KPa; Pressure Range Standard Range Overload Pressure Burst Pressure ±0.5%F.S (include no-linearity, hysteresis, repeatability, and calibration error) Note1 Long-term Stability. Response Time Medium Temperature Ambient Temperature Compensated Temperature Storage Temperature Output Signal Supply Voltage Current without Load Output Load Reverse Voltage Insulate Resistance Dielectric Strength
Open the catalog to page 2CS-PT300G Series Pressure Transmitter Random Vibration
Open the catalog to page 3CS-PT300G Series Pressure TransmitterPressure Connector Electrical Connection Packard
Open the catalog to page 4CS-PT300G Series Pressure Transmitter Waterproof outlet PT300G Series Pressure Transmitter
Open the catalog to page 51. The transmitter must be used in a medium that is not corrosive to the sealing material and housing material. 2. When the pressure-guiding hole of the transmitter is blocked, it is strictly forbidden to use a sharp tool to clear the pressure-guiding hole. The transmitter should be removed and the pressure-guiding hole should be immersed in a liquid that can dissolve the blockage. After the blockage is dissolved, remove it fall out. 3. It is strictly forbidden to open the transmitter for calibration or maintenance by yourself. 4. If you are not sure whether the transmitter is suitable for the...
Open the catalog to page 6CS-PT300G Series Pressure Transmitter The company reserves the right to modify the specifications and contents of this manual. Subject to modification without notice. Due to the update of the product, the individual details of this document may not match the product, please refer to the actual product. The interpretation right of this document belongs to our company.
Open the catalog to page 79 Pages
7 Pages
7 Pages
6 Pages
5 Pages
6 Pages
5 Pages
6 Pages
6 Pages
5 Pages
6 Pages
6 Pages
6 Pages
4 Pages
5 Pages
6 Pages
8 Pages
9 Pages
8 Pages
1 Page
1 Page
1 Page
2 Pages
2 Pages
2 Pages
1 Page
1 Page
1 Page
1 Page