X-134

X-134

X-134

Product catalog summary
Overview
The document provides technical specifications and details for the X-134 series precision load cells, designed for measuring tension and compressive forces. These load cells are available in three models: X-134-A, X-134-B, and X-134-C, each with different force measurement capacities and dimensions.

Specifications
  • Models and Capacities: X-134-A (up to 50 kN), X-134-B (up to 200 kN), X-134-C (up to 500 kN).
  • Dimensions: Varying diameters and heights for each model.
  • Material: Solid steel housing with PVC cables.
  • Protection: Encapsulated version with IP65 rating for environmental protection.
  • Output Signal: 4 mV/V at full scale.
  • Electrical Resistance: 350 Ohm strain gauge bridge.

Performance Characteristics
  • Accuracy: Deviation sensitivity ±0.3%, zero signal unmounted <1% from full-scale, repeatability <0.02% from full-scale, combined error <0.15% from full-scale.
  • Temperature Influence: On final value ±0.015% FS/10°C, on zero point ±0.026% FS/10°C.
  • Mechanical Data: Overload capacity of 130% from full-scale, life endurance of 10 million cycles at 50% load, deflection at full scale <0.5 mm.

Installation and Usage
  • Easy installation with metal screws, though screws are not included.
  • Zero point adjustment can be performed via connected strain gauge amplifiers, with options for cyclical and static applications.

Accessories
  • Junction boxes for connecting multiple strain gauge sensors to an amplifier.
  • Measuring amplifiers for static and cyclic applications, available in DIN rail or aluminum field housing.
  • Various cable connectors and plugs for electrical connections.

Additional Notes
The document emphasizes the importance of understanding linearity, repeatability, and hysteresis for accuracy in force measurement. It also provides guidance on zero point adjustment and sensitivity deviations.
See more

Catalog excerpts

X-134-1

Precision load cell for measuring tension and compressive forces With internal thread for force introduction With ball radius as force introduction With ball radius as force introduction Features • Solid steel housing • Encapsulated version IP65 • Easy installation with metal screws • Unit sensitivity • Specific measuring ranges available Application The load cell X-134 is suitable for force measurement in applications where high accuracies are required. The load cells can be calibrated and supplied with a recognized calibration certificate if required. The sensors are based on proven strain gauge technology and provide a linear signal, proportional to the measured force. The solid steel housing and the sealed construction (IP65) guarantee a trouble-free operation, even under harsh environmental c

 Open the catalog to page 1
X-134-2

Description Measuring Output- Contact Assembly Characteristic Specificati range signal surface in mm ons X-134-20 0 ... 20 kN 4 mV /V 0 104.7 x 34.8 mm 8x screws With internal thread for force Page 3 introduction X-134-50 0 ... 50 kN 4 mV /V 0 104.7 x 34.8 mm 8x screws With internal thread for force Page 3 introduction X-134-100 0 ... 100 kN 4 mV /V 0 120.7 x 53.8 mm 4x screws With ball radius as force Page 4 introduction X-134-200 0 ... 200 kN 4 mV /V 0 120.7 x 53.8 mm 4x screws With ball...

 Open the catalog to page 2
X-134-3

Mechanical dimensions The load cell is delivered without fixing screws. For detailed ordering information see page 2.

 Open the catalog to page 3
X-134-4

Precision load cell X-134-B 0 120.7 x 53.8 mm, Up to 200 kN Mechanical dimensions The load cell is delivered without fixing screws. For detailed ordering information see page 2.

 Open the catalog to page 4
X-134-5

Precision load cell X-134-C 0 138 x 57.2 mm, Up to 500 kN Mechanical dimensions The load cell is delivered without fixing screws. For detailed ordering information see page 2.

 Open the catalog to page 5
X-134-6

Zero point adjustment The zero point adjustment at force sensors with a mV/V-output signal is carried out in the connected strain gauge amplifiers. For X-Sensors two options for zero point adjustment are available: For cyclical and fast load changes, there is a control input to trigger the zero point adjustment from external. For static applications, the zero point adjustment can be carried out onboard by means of DIP-switches and potentiometers. Further information concerning the zero point adjustment can be found in data sheets of the measuring amplifiers listed in the accessories. Definition...

 Open the catalog to page 6
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.