Overview: The document provides detailed specifications and application guidelines for the X-103 series strain sensors with mV/V-output, utilizing a DMS measuring bridge. These sensors are designed for measuring strain in static and dynamic applications, particularly in force, weight, and deformation measurements.
Specifications:
  • Models: X-103-D10, X-103-D15, X-103-D20, X-103-D30.
  • Measuring Range: 0…250 µm/m for D10, D15, D30; 0…1000 µm/m for D20.
  • Output Signal: Varies from +1.0 mV/V to +3.0 mV/V depending on the model.
  • Bridge Resistance: 350 Ohm for D10, D15; 1000 Ohm for D20; 2…5 kOhm for D30.
  • Housing: Steel with IP65 or IP67 protection.
  • Power Supply: 2…15 VDC.
Mechanical and Environmental Data:
  • Dimensions: Varies slightly between models, with a very flat design.
  • Overload Capacity: Up to 150% of full scale.
  • Temperature Range: -10 to 65 ºC.
  • Protection Rate: IP65 or IP67 depending on the model.
Applications: Suitable for use in harsh environments due to robust steel housing and high protection rating. Ideal for applications requiring multiple sensors connected in parallel, such as weight and force measurements in presses.
Mounting Instructions: Sensors should be mounted on machined surfaces with specific flatness and tightened using specified torque values for optimal performance.
Accuracy and Calibration:
  • Linearity and Hysteresis: Defined in relation to the ideal BFSL curve, with maximum errors specified.
  • Sensitivity: Slight deviations are specified for each sensor type.
  • Repeatability: Reinstallation may cause minimal zero-point shifts, which can be recalibrated.
Accessories: Includes junction boxes and amplifiers for static and dynamic applications, with various cable and connector options for integration.
See more

Catalog excerpts

Strain sensor with mV/V-output (DMS measuring bridge)-1

For 0.250 Mm/m with very high sensitivity • Very flat design with only 6.5 mm height • Very high sensitivity and resolution • Strain sensor with mV/V-output (DMS measuring bridge) • For static and dynamic applications • For force, weight and deformation measurements • Measuring very small strains in rigid structures Surface strain sensor X-103 monitors the strain between its two mounting screws and amplifies this mechanically. In this way the strain is concentrated in the measuring area and can therefore be measured using a resistive strain gauge bridge. These strain sensors are used if the mV/V-signal of a DMS measuring bridge is used if more than one strain sensor should be connected in parallel. This is the case for weight measurements and for force measurement at several tie-bars of a press. The strain sensor will generate a proportional DMS bridge signal (mV/V) depending on the stress of the structure. An extremely solid steel housing, combined with IP65 protection guarantees trouble-free operation, even under harsh and rugged environment conditions.

 Open the catalog to page 1
Strain sensor with mV/V-output (DMS measuring bridge)-2

Measuring Bridge Output signal Ordering coderange resistance X-103-D10 M12 plug 0...250 [Jm/m 350 Ohm +1.0 mV/V X-103-D10-M12-350Ohm-CAL250 Order information: Type/Description Measuring range Output signal Cable length / connector Options: CON: Cable connector at the free end LEN: Customer specific cable length Strain sensor with DMS measuring bridge

 Open the catalog to page 2
Strain sensor with mV/V-output (DMS measuring bridge)-3

Strain sensor X-103-D10 with M12 plug 93 x 25 x 14 mm, 4x M6, 0...250 pm/m, +1 mV/V Specifications! Mechanical dimensions! Performance Ordering information This strain sensor is delivered without mounting screws. For detailed ordering information, please see page 2. Strain sensor with DMS measuring bridge

 Open the catalog to page 3
Strain sensor with mV/V-output (DMS measuring bridge)-4

Strain sensor X-103-D15 89 x 26 x 6.5 mm, 4x M6, 0...250 pm/m, +1.5 mV/V Specifications Electrical data Strain sensor with DMS measuring bridge

 Open the catalog to page 4
Strain sensor with mV/V-output (DMS measuring bridge)-5

Strain sensor X-103-D20 89 x 26 x 6.5 mm, 4x M6, 0...1000 pm/m, +2 mV/V Specifications Electrical data Mechanical data Ordering information This strain sensor is delivered without mounting screws. For detailed ordering information, please see page 2. Strain sensor with DMS measuring bridge

 Open the catalog to page 5
Strain sensor with mV/V-output (DMS measuring bridge)-6

Strain sensor X-103-D30 with high sensitivity 89 x 26 x 6.5 mm, 4x M6, 0...250 pm/m, +3 mV/V Specifications! Mechanical dimensions! Performance Strain sensor with DMS measuring bridge

 Open the catalog to page 6
Strain sensor with mV/V-output (DMS measuring bridge)-7

The zero adjustment at the strain sensors with DMS bridge output signal (mV/V) is done at the subsequent amplifier. X-SENSORS offers two different types of amplifiers: One for static applications and one for dynamic applications. For dynamic applications, a digital input for automatic zero-point adjustments is offered. For static applications, the zero point can be adjusted manually by DIP switches and by a potentiometer for fine tuning. The strain sensors should be mounted on machined surfaces N9 with a flatness to within 0,5 mm. Use the following parameter for tighten the socket screws: The...

 Open the catalog to page 7
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.