AA4530F
4Pages

{{requestButtons}}

Catalog excerpts

AA4530F - 1

AA4530F Atomic Absorption Spectrophotometer CHARACTERISTICS 1. Completely controlled by PC, can flexibly select the flame and graphite furnace atomizer (optional). 2. Integrated floated optical platform design can obviously improve the optical system shock resistance and keep stable though use the optical signal for a long term. 3. Eight light stands can be changed automatically and preheat the eight lights meantime as well as optimize the working condition of the hollow cathode lamp. 4. Position adjusting: the best height of the flame burner and can automatically set the front and rear positions. 5. Fully automated wavelength scanning and peak searching. 6. Complete safety chains protection equipment: the function of warning and automatic safety protection towards the wrong burner, leakage of the gas, under voltage of air and the abnormal flameout. 7. Deuterium lamp and self-absorption background regulation. 8. Data processing: super strong database, possesses more than 500 data self-storage and cut-off storage function, can store the analyzed result with the form of EXCEL and the testing method and the result can be randomly called. 9. Measuring method: flame absorption method and emission method. 10.Result printing: parameter printing, data result printing and diagram printing. COMPLETE AUTOMATIC CONTROLLING SYSTEM With the help of the software, the following can be easily achieved 1. Selection of the element lamp 2. Up-down-front-rear adjustment of the lifter 3. Adjustment of the optical energy 4. Selection of the slit 5. Determination of wavelength scanning and peak searching 6. Selection of the atomizer 7. Setting of the background deduction method 8. Controlling of the gas flow 9. Automatic flaming and flaming out 10.Setting of the graphite furnace testing method

Open the catalog to page 1
AA4530F - 2

ADVANCED GRAPHITE FURNACE TEMPERATURE CONTROLLING TECHNOLOGY l The bringing in of PID technology can effectively overcome the influence on the temperature rising process caused by the voltage fluctuation and the resistance change to make more accurate controlling process. The combination of the 3ms/time fast sampling technique can make more accurate and reliable testing data ^ The fast heating capacity can improve the flexibility of the elements further n Use the ordinary power source of 220V without need of dynamic power of 380V & The maximum procedure heating capacity setting of 20 levels...

Open the catalog to page 2
AA4530F - 3

AA4530F Atomic Absorption Spectrophotometer SPECIFICATIONS Wavelength range Spectral bandwidth Accuracy of the wavelength Receptivity of the wavelength Base line stability Characteristic viscosity Checking limit Preciseness Grating Inflamer Atomizer Lamp stand D2 background correction ability Size and weight Power source 190 – 900nm 0.1, 0.2, 0.4, 1.0 and 2.0nm ± 0.15nm ≤0.04nm ≤0.002A/30min (Cu) 0.02μg/ml/1% (Cu) 0.004μg/ml (Cu) 0.5% 1800 lines/mm All-metal titanium burner Effective glass atomizer 8 When the background is 1 A, the background ability should be deducted not less than 50...

Open the catalog to page 3

All Wuxi Jiebo Electrical Technology Co. catalogs and technical brochures

  1. EDX 8300

    4 Pages

  2. JB-TS6

    2 Pages

  3. AA320N

    2 Pages