AA320N
2Pages

{{requestButtons}}

Catalog excerpts

AA320N - 1

AA320N Atomic Absorption Spectrophotometer Build-in computer data processing and LCD display: stable and reliable with the functions of integral holding, peak height and area, auto zero adjusting, deuterium lamp background correction, multi-linear and nonlinear curves fitting, various parameters and working curves displayed in screen and report printing, etc. It is equipped with interface for externally linking PC. Stability: Double-beam system can automatically compensate the light source drift and wavelength drift caused by the variation of temperature (with the function of the eliminating the affection of wavelength drift on the base line stability) and electronic circuit drift so as to reach a good basic line stability. Quickly: The cathode lamp needs not be pre-heated for long time and sample can be analyzed immediately. It is the preferable instrument chosen by users to conduct analysis of multiple kinds of elements and fast analysis of samples. High precision of measurement: Gas path system is equipped with precision pressure stabilizing and current stabilizing devices to reach stable flame and low noise. Specially designed fine light beam passes through the flame to ensure a high precision analytical test and low characteristic concentration High energy optical path: A total reflection system is adopted to eliminate color difference in full range. By means of chemical conversion, a round light spot of the light source becomes a long light spot, which enters into the slit. Therefore the light flux of double beam is enhanced. Long-life and anti-corrosive atomization system: The burner is made of new type titanium alloys, anti-corrosive and fast thermal equilibrium. It meets the requirement of measurement sensitivity without water-cooling. Multi-functional analysis mode: for methods of flame absorption, flame emission, graphite furnace atomic absorption and hydride generation. Safe and reliable gas path system: Special devices of quick gas conversion and safety protection can be used to analyze air-acetylene flame as well as nitrous oxide-acetylene flame and extend the analytic elements to reach more than 60. Complete set of accessories: to be supplied with the instrument and ready for use after they are purchased.

Open the catalog to page 1
AA320N - 2

Specifications WL range (nm) WL accuracy WL repeatability Spectrum bandwidth Resolution Base line stability Characteristic concentration of copper Detection limit of copper Background calibration ability RS232 Printer Power supply G.W. Package Dimensions Standard Accessories Oil-free air compressor EPSON Printer Glass Atomizer Cu Hollow cathode lamp Atomizer unit Burner unit Dust cover Water-separating gas filter Titanium burner—10cm Optional Accessories Model GA3202 HGA graphite furnace system Titanium burner—5cm Nitrous oxide generator Hydride generator Graphite tubes Acetylene Regulator...

Open the catalog to page 2

All Wuxi Jiebo Electrical Technology Co. catalogs and technical brochures

  1. EDX 8300

    4 Pages

  2. JB-TS6

    2 Pages

  3. AA4530F

    4 Pages