video corpo

BWSENSING BWS2500
12Pages

{{requestButtons}}

Catalog excerpts

BWSENSING BWS2500 - 1

BWS2500 Ultra High Precision Dual-Axis * * * ‘Output Inclinometer Technical Manual

Open the catalog to page 1
BWSENSING BWS2500 - 2

Ultra High Precision Dual-Axis CAN Output Inclinometer Introduction Designed by Bewis Sensing Technology LLC, BWS2500 is a ultra high precision dual-axis CAN output inclinometer with MEMS technology. It has a measuring range of ± 30° and the highest accuracy of 0.001°. It is a highly accurate product in the industry for now. The product has automatic compensation and filtering algorithms to reduce errors caused by environmental changes. It measures the change of static gravitational field and converts it into angle change. The change directly outputs the current roll angle and pitch angle...

Open the catalog to page 2
BWSENSING BWS2500 - 3

Specifications © Electrical Specifications Parameters Conditions Min Typical Max Units Operating current Non-loaded 20 30 40 mA Performance Specifications Measuring range(°) Conditions ±5 ±15 ±30 Measuring axis Vertically X-Y X-Y X-Y Cross axis error(°) Max 0.001 0.001 0.001 Baud rate Adjustable 2400~115200 2400~115200 2400~115200 Weight (g) 320 (Metal connector)/350 (Aviation connector) Resolution: The measured minimum change value that the sensor can detect and resolve within the measurement range. Accuracy: The error between the actual angle and the Root mean square(RMS) of the measured...

Open the catalog to page 3
BWSENSING BWS2500 - 4

BWS 2500 Ultra High Precision Dual-Axis CAN Output Inclinometer Connector Metal connector Shell material Magnesium alloy oxidation Installation Three M4 screws Product size: L69*W49*H12(mm) Note: ±1mm error for length and width dimensions, please refer to actual size. Bewis SensinglTechnologylLLC

Open the catalog to page 4
BWSENSING BWS2500 - 5

Ultra High Precision Dual-Axis CAN Output Inclinometer Installation direction The correct installation method can avoid measurement error. The following points should be made when installing the sensor: First of all, to ensure that the sensor mounting surface and the measured surface completely close, the measured surface should be as horizontal as possible, can not have the angle shown in Figure A and Figure C, the correct installation is shown in Figure B and Figure D. B uneven surface generates the angle D uneven surface generates the angle Secondly, the bottom cable of the sensor and...

Open the catalog to page 5
BWSENSING BWS2500 - 6

BWS 2500 Ultra High Precision Dual-Axis CAN Output Inclinometer Electrical connections Electrical interfaces Cable color & Function 4 GREEN 3 •-»|black gnd|• CAN BUS wiring diagram Bewis SensinglTechnologylLLC

Open the catalog to page 6
BWSENSING BWS2500 - 7

Protocol CAN includes 8 bytes. It will adds 0 to it when the date bytes is not enough. Sending the first byte 0x40 indicates a write command, and returning the first byte 0x40 indicates that the write was successful. The ID is the CAN communication node number. Note: the fifth byte (Baud) means 0x01,0x02, 0x03, 0x04. 0x01 means to set 500k bps as the baud rate. 0x02 means to set 250k bps as the baud rate. 0x03 means to set 125k bps as the baud rate. 0x04 means to set 100k bps as the baud rate. The default baud rate is 125k bps. Once you revise the baud rate and want to make a success...

Open the catalog to page 7
BWSENSING BWS2500 - 8

4) Query relative/ absolute zero CAN-ID bytefirst second third f°urth fifth sixth seventh eighth Note: the fifth byte means 0x00 and 0x01.0x00 indicates an absolute zero and 0x01 indicates a relative zero. CAN-ID bytefirSt second third fourth fifth sixth seventh eighth Note: For some parameter, revised parameter doesn't work until you send the saving command. CAN-ID bytefirSt second third fourth fifth sixth seventh eighth response 0x580 + 0x05 Xsign XH XL XL Ysign YH YL YL Note: Reading angle command can be effective under the response mode. Xsign and Ysign are the sign positions of the X...

Open the catalog to page 8
BWSENSING BWS2500 - 9

8) Inclinometer sensor automatically outputs the angle When the sensor is set to automatic mode output, the sensor automatically outputs the angle according to a certain frequency after the sensor is powered on. CAN-ID bytefirSt second third fourth fifth sixth seventh eighth send response 0x580 + 0x05 Xsign XH XL XL Ysign YH YL YL Note: The output angle format is the same as the answer mode read X and Y angles. CAN-ID bytefirSt second third fourth fifth sixth seventh eighth response Note: XX means 00 and 01. 00 means the standard ID type (11 bits) and 01 means extended ID type (27 bits)....

Open the catalog to page 9
BWSENSING BWS2500 - 10

BWS 2500 Ultra High Precision Dual-Axis CAN Output Inclinometer We need to divide the address into two when setting the address of extended CAN-ID. First send high 16 address, then send the low 16 address. The CAN-ID address will change into new one (here the CAN-ID address we receive do not need to add the nodes) after being re-powered on. The maximum can not be more than 0x1FFFFFFF. The default is 0x18fa0216. I Set high 16 extended address of CAN-ID CAN-ID bytefirSt second third f°urth fifth sixth seventh eighth response Note: the high 16 address can not surpass 0X1FFF. n Set low 16...

Open the catalog to page 10
BWSENSING BWS2500 - 11

Ultra High Precision Dual-Axis CAN Output Inclinometer Executive standard Enterprise Quality System Standard: ISO9001:2008 Standard (Certificate No.10114Q16846ROS) CE certification (certificate number: 3854210814) HS (certificate number: G190930099) Bewis Sensing Technology LLC

Open the catalog to page 11
BWSENSING BWS2500 - 12

Ultra High Precision Dual-Axis CAN Output Inclinometer Wuxi Bewis Sensing Technology LLC Address: Building 30, No. 58 Xiuxi Road, Binhu District, Wuxi City, Jiangsu Province, China Tel/Whatsapp: +86 18921292620 Email: support@bwsensing.com Website: www.bwsensing.com

Open the catalog to page 12

All Wuxi Bewis Sensing Tecnology LLC catalogs and technical brochures