Group: BWSENSING
Catalog excerpts
BWN427 Cost-effective Dual-Axis Digital Output with Modbus Inclinometer Technical Manual
Open the catalog to page 1Cost-effective Dual-Axis Digital Output with Modbus Inclinometer Introduction Designed by Bewis Sensing Technology LLC, BWN427 is a cost-effective dual-axis digital output with Modbus inclinometer with MEMS technology. It has a measuring range of ±30° and a full-scale accuracy of 0.02° and a operating temperature of -40℃~+85℃. The product uses automatic compensation and filtering algorithms to reduce errors caused by environmental changes. It measures the change of static gravitational field and converts it into angle change. The change directly outputs the horizontal angle value through...
Open the catalog to page 2Cost-effective Dual-Axis Digital Output with Modbus Inclinometer Parameters Conditions Min Typical Max Units Operating current Non-loaded 20 30 40 mA Measuring range Measuring axis Accuracy Resolution Zero temperature drift Cross axis error Frequency response Shock resistance MTBF Electromagnetic compatibility Insulation resistance Resolution: The measured minimum change value that the sensor can detect and resolve within the measurement range. Accuracy: The error between the actual angle and the Root mean square(RMS) of the measured angle of the sensor (>16 times). Bewis...
Open the catalog to page 3Cost-effective Dual-Axis Digital Output with Modbus Inclinometer Mechanical Characteristic Connector Metal connector Protection level Shell material Magnesium alloy anodizing Package size Product Size: L90*W40.5*H26(mm) Bare plate product size Product size: L47*W36*H15(mm) Note: ±1mm error for length and width dimensions, please refer to actual size. Bewis Sensing Technology LLC
Open the catalog to page 4Cost-effective Dual-Axis Digital Output with Modbus Inclinometer Installation direction The correct installation method can avoid measurement error. The following points should be made when installing the sensor: First of all, to ensure that the sensor mounting surface and the measured surface completely close, the measured surface should be as horizontal as possible, can not have the angle shown in Figure A and Figure C, the correct installation is shown in Figure B and Figure D. A B uneven surface generates the angle D uneven surface generates the angle Secondly, the bottom cable of the...
Open the catalog to page 5Elect ri cal connections Electrical interfaces Cable color & Function Inclinometer 4 ■•^YELLOW D+ -•( GREEN D-^» 485~ SiqnaJI eccjuisition Bewis SensinglTechnologylLLCP
Open the catalog to page 6Cost-effective Dual-Axis Digital Output with Modbus Inclinometer Users can directly download serial assistant on official website (Supports-Download). You can also use more convenient and intuitive PC software. BWN427 supporting serial debugging software can be connected to the inclinometer on the computer for angle display. The software debugging interface is as shown in the figure below. Using the debug software, it can conveniently display the current X-direction tilt angle, and you can also modify and set other parameters by yourself. Software use steps: @ Correctly connect the...
Open the catalog to page 7BWN 427 Cost-effective Dual-Axis Digital Output with Modbus Inclinometer 1 Data Frame Format: (8 data bits, 1 stop bit, non verification, default rate 9600) Address Functi0n The first high The first low High Low register Checksum Code C0de address address register number (2byte) (Ibyte) (Ibyte) register register number (1byte) (Ibyte) (Ibyte) (Ibyte) Data format: Hexadecimal Address code: Default 01 (note: it should not exceed FF) Function Code: 03 represents reading register,06 represents presetting register. Register Address: the starting address the register need to be operated Register...
Open the catalog to page 8BWN 427 Cost-effective Dual-Axis Digital Output with Modbus Inclinometer Address Function Code Code (Ibyte) (Ibyte) The first high address register (Ibyte) 0x00 The first low address register (Ibyte) 0x02 High register number (Ibyte) 0x00 Low register number (Ibyte) Command response: 2.3 Read angle of both X-axis and Y-axis Command: 01 03 00 01 00 02 95 CB Address Code (Ibyte) Function Code (Ibyte) The first high address register (Ibyte) 0x00 The first low address register (Ibyte) 0x01 High Low register Checksum register number (2byte) Command response: Address Code Function Code The high...
Open the catalog to page 9Address Code Function Code The high address The low address Data field Checksum (Ibyte) (1byte) register (1byte) register (1byte) (2byte) (2byte) Command response: Address Code Function Code The high address The low address Data field Checksum (Ibyte) (Ibyte) register (1byte) register (1byte) (2byte) (2byte) Note: If Save setting command is not executed, all setting will be invalid after power off. Bewis SensinglTechnologylLLC
Open the catalog to page 11Cost-effective Dual-Axis Digital Output with Modbus Inclinometer Executive standard ● Enterprise Quality System Standard: ISO9001:2008 Standard (Certificate No.10114Q16846ROS) ● CE certification (certificate number: 3854210814) ● RoHS (certificate number: G190930099) Bewis Sensing Technology LLC
Open the catalog to page 12BWN427 Cost-effective Dual-Axis Digital Output with Modbus Inclinometer Wuxi Bewis Sensing Technology LLC Address: Building 30, No. 58 Xiuxi Road, Binhu District, Wuxi City, Jiangsu Province, China Tel/Whatsapp: +86 189 2129 2620 Email: support@bwsensing.com Website: www.bwsensing.com
Open the catalog to page 13All Wuxi Bewis Sensing Tecnology LLC catalogs and technical brochures
-
GI320
25 Pages
-
BWSENSING BWK217S
8 Pages
-
AH100C
9 Pages
-
LoRaWAN G500 Gateway
1 Pages
-
LoRaWAN G200 Gateway
1 Pages
-
BWSENSING BWS5000E
14 Pages
-
BWSENSING Catalog 2020
60 Pages
-
BWSENSING BWK228
13 Pages
-
BWSENSING BWK218
12 Pages
-
BWSENSING BWK220
13 Pages
-
BWSENSING BWK210
13 Pages
-
BWSENSING BWK227S
13 Pages
-
BWSENSING BWK226S
13 Pages
-
BWSENSING BWK225S
12 Pages
-
BWSENSING BWK216S
12 Pages
-
BWSENSING BWK215S
12 Pages
-
BWSENSING BWL320
13 Pages
-
BWSENSING BWL328
13 Pages
-
BWSENSING BWL318
12 Pages
-
BWSENSING BWL310
13 Pages
-
BWSENSING BWL327S
13 Pages
-
BWSENSING BWL326S
13 Pages
-
BWSENSING BWL325S
12 Pages
-
BWSENSING BWL317S
12 Pages
-
BWSENSING BWL316S
12 Pages
-
BWSENSING BWL315S
12 Pages
-
BWSENSING BWN460
12 Pages
-
BWSENSING BWN428
13 Pages
-
BWSENSING BWN425
12 Pages
-
BWSENSING BWN420
13 Pages
-
BWSENSING BWM460
12 Pages
-
BWSENSING BWM427
13 Pages
-
BWSENSING BWM426
13 Pages
-
BWSENSING BWM425
12 Pages
-
BWSENSING BWM420
13 Pages
-
BWSENSING BWM418
12 Pages
-
BWSENSING BWM417H
12 Pages
-
BWSENSING BWM417
12 Pages
-
BWSENSING BWM416
12 Pages
-
BWSENSING BWM415
12 Pages
-
BWSENSING BWM410
12 Pages
-
BWSENSING BWH528
14 Pages
-
BWSENSING BWH527
13 Pages
-
BWSENSING BWH526
14 Pages
-
BWSENSING BWH525
12 Pages
-
BWSENSING BWH520
14 Pages
-
BWSENSING BWH518
13 Pages
-
BWSENSING BWH517
12 Pages
-
BWSENSING BWH516
13 Pages
-
BWSENSING BWH515
12 Pages
-
BWSENSING BWH510
13 Pages
-
BWSENSING BWS5500
12 Pages
-
BWSENSING BWS4800
14 Pages
-
BWSENSING BWS5700
13 Pages
-
BWSENSING BWS2500
12 Pages
Archived catalogs
-
BWSENSING BWN426
13 Pages