BWN420 Cost-effective Dual-Axis Voltage Output Inclinometer Technical Manual
Open the catalog to page 1Cost-effective Dual-Axis Voltage Output Inclinometer Introduction Designed by Bewis Sensing Technology LLC, BWN420 is a cost-effective dual-axis voltage output inclinometer with MEMS technology. It has a measuring range of ±30° and a full-scale accuracy of 0.02° and a operating temperature of -40℃~+85℃. The product uses automatic compensation and filtering algorithms to reduce errors caused by environmental changes. It measures the change of static gravitational field and converts it into angle change. The change directly outputs the horizontal angle value through voltage mode. It has high long-term...
Open the catalog to page 2BWN 420 Cost-effective Dual-Axis Voltage Output Inclinometer Parameters Conditions Min Typical Max Operating current Non-loaded 20 30 40 Output load Resistivity 10 temperature Store temperature -55 +100 Parameters Measuring range Measuring axis Accuracy Resolution Zero temperature drift Full scale output voltage Frequency response Shock resistance N.W. MTBF Electromagnetic compatibility Insulation resistance Resolution: The measured minimum change value that the sensor can detect and resolve within the measurement range. Accuracy: The error between the actual angle and the Root mean square(RMS)...
Open the catalog to page 3Cost-effective Dual-Axis Voltage Output Inclinometer Mechanical Characteristic Connector Metal plug Protection level Shell material Magnesium alloy anodizing Package size Product Size: L90*W40.5*H26(mm) Bare plate product size Product size: L47*W36*H15(mm) Note: ±1mm error for length and width dimensions, please refer to actual size. Bewis Sensing Technology LLC
Open the catalog to page 4Cost-effective Dual-Axis Voltage Output Inclinometer Installation direction The correct installation method can avoid measurement error. The following points should be made when installing the sensor: First of all, to ensure that the sensor mounting surface and the measured surface completely close, the measured surface should be as horizontal as possible, can not have the angle shown in Figure A and Figure C, the correct installation is shown in Figure B and Figure D. A B uneven surface generates the angle D uneven surface generates the angle Secondly, the bottom cable of the sensor and the...
Open the catalog to page 5Elect ri cal connections Electrical interfaces Output Ground Cable color & Function Cable color & Function Bewis SensinglTechnologylLLC
Open the catalog to page 6Cost-effective Dual-Axis Voltage Output Inclinometer Debug software Users can directly download serial assistant on official website (Supports-Download). You can also use more convenient and intuitive PC software. BWN420 supporting serial debugging software can be connected to the inclinometer on the computer for angle display. The software debugging interface is as shown in the figure below. Using the debug software, it can conveniently display the current X-direction and Y-direction tilt angle, and you can also modify and set other parameters by yourself. Software use steps: ① Correctly connect...
Open the catalog to page 7BWN 420 Cost-effective Dual-Axis Voltage Output Inclinometer IData Frame Format: (8 data bits,1 stop bit,No parity check,default baud rate 9600)
Open the catalog to page 8Data Checksum 3emmer Frame Length Address Code Command (1byte) (Ibyte) (Ibyte) (Ibyte) Command response: |dentifier Frame Length Address Code Command Data Checksum (1byte) (Ibyte) (Ibyte) (Ibyte) (9byte) (Ibyte) Note: The returned 9 bytes are divided into three groups, which are the x-axis angle, the y-axis angle, and the z-axis angle (or reserved bit). (The z-axis characterizes the angle between the product's vertical line and the vertical line); See the directive 2.1 for the format. Bewis SensinglTechnologylLLC
Open the catalog to page 9Identifier Frame Length Address Code Command Data Checksum (Ibyte) (Ibyte) (Ibyte) (ibyte) (1byte) (1byte) Command response: Data Checksum (ibyte) (ibyte) Identifier Frame Length Address Code Command (ibyte) (1byte) (ibyte) (ibyte) Note: Set baud rate to 115200 in high speed mode. When the Set baud rate command is executed successfully, the command response will be return in the original baud rate and then communicate with new baud rate. Identifier Frame Length Address Code (Ibyte) (Ibyte) (1byte) Command Data Checksum (Ibyte) 0x00: question and answer Mode Data Rate Data Rate Data Rate Data...
Open the catalog to page 10Cost-effective Dual-Axis Voltage Output Inclinometer Identifier Frame Length (Ibyte) (Ibyte) Command response: Identifier Frame Length Address Code Command Data Checksum Address Code (Ibyte) Command Data Checksum Identifier Frame Length Address Code Command Data Checksum (1byte) (Ibyte) (Ibyte) (Ibyte) (0byte) (Ibyte) Command response: Identifier Frame Length Address Code Command Data Checksum (1byte) (Ibyte) (Ibyte) (Ibyte) (Ibyte) (Ibyte) Identifier Frame Length Address Code Command Data Checksum (1byte) (Ibyte) (Ibyte) (Ibyte) (0byte) (Ibyte) Command response: Identifier (Ibyte) Frame Length...
Open the catalog to page 11Cost-effective Dual-Axis Voltage Output Inclinometer Executive standard ● Enterprise Quality System Standard: ISO9001:2008 Standard (Certificate No.:10114Q16846ROS) ● CE certification (certificate number: 3854210814) ● RoHS (certificate number: G190930099) Bewis Sensing Technology LLC
Open the catalog to page 12Cost-effective Dual-Axis Voltage Output Inclinometer Wuxi Bewis Sensing Technology LLC Address: Building 30, No. 58 Xiuxi Road, Binhu District, Wuxi City, Jiangsu Province, China Tel/Whatsapp: +86 189 2129 2620 Email: [email protected] Website: www.bwsensing.com
Open the catalog to page 135 Pages
4 Pages
5 Pages
25 Pages
8 Pages
9 Pages
1 Page
1 Page
14 Pages
60 Pages
13 Pages
12 Pages
13 Pages
13 Pages
13 Pages
13 Pages
12 Pages
12 Pages
12 Pages
13 Pages
13 Pages
12 Pages
13 Pages
13 Pages
13 Pages
12 Pages
12 Pages
12 Pages
12 Pages
12 Pages
13 Pages
13 Pages
12 Pages
12 Pages
13 Pages
13 Pages
12 Pages
13 Pages
12 Pages
12 Pages
12 Pages
12 Pages
12 Pages
12 Pages
14 Pages
13 Pages
14 Pages
12 Pages
14 Pages
13 Pages
12 Pages
13 Pages
12 Pages
13 Pages
12 Pages
14 Pages
13 Pages
12 Pages
13 Pages