Group: BWSENSING
Catalog excerpts
BWK225S Low Cost Dual-Axis CAN Output Inclinometer Technical Manual
Open the catalog to page 1BWK 225S Low Cost Dual-Axis CAN Output Inclinometer Introduction Designed by Bewis Sensing Technology LLC, BWK225S is a low cost dual-axis CAN output Inclinometer, adopting the latest industrial level MEMS accelerometer. Its measuring range is ±90°, highest accuracy is 0.2°, working temperature is -40℃~+85℃, the product with a small size and low weight, can meet space-restricted application requirements. This product converts static gravity field changes into angle changes, It outputs horizontal angle values directly by digital, this product has the advantages of low cost, small temperature...
Open the catalog to page 2Specifications© Electrical Specifications Parameters Resolution: The measured minimum change value that the sensor can detect and resolve within the measurement range. Accuracy: The error between the actual angle and the Root mean square(RMS) of the measured angle of the sensor (>16 times). Bewis SensinglTechnologyiLLCl
Open the catalog to page 3BWK 225S Low Cost Dual-Axis CAN Output Inclinometer BWSGNSINGMechanical Characteristic Connector Bare plate product size Product size: L33*W27*H6(mm) Note: ±1mm error for length and width dimensions, please refer to actual size. Bewis SensinglTechnologyiLLCl
Open the catalog to page 4BWK 225S Low Cost Dual-Axis CAN Output Inclinometer Installation direction The correct installation method can avoid measurement error. The following points should be made when installing the sensor: First of all, to ensure that the sensor mounting surface and the measured surface completely close, the measured surface should be as horizontal as possible, can not have the angle shown in Figure A and Figure C, the correct installation is shown in Figure B and Figure D. A B uneven surface generates the angle D uneven surface generates the angle Secondly, the bottom cable of the sensor and the...
Open the catalog to page 5Elect ri cal connections Electrical interfaces Cable color & function Bewis SensinglTechnologyiLLCl
Open the catalog to page 6Protocol CAN includes 8 bytes. It will adds 0 to it when the date bytes is not enough. Sending the first byte 0x40 indicates a write command, returning the first byte 0x40 indicates that the write was successful. The ID is the CAN communication node number. Note: The fifth byte means 0x00 and 0x01. 0x00 indicates the setting is an absolute zero,0x01 indicates a relative zero. After setting the zero point, you need to enter the save command to set it successfully. (Default is absolute zero) Absolute zero: Based on the factory-calibrated zero point. Relative zero: Reference to the zero after...
Open the catalog to page 74) Query relative/ absolute zero Note: The fifth byte mode is 0x00: answer mode, 0x01 : 5Hz Data Rate, 0x02: 1 0Hz Data Rate 0x03: 20Hz Data Rate, 0x04: 25Hz Data Rate, 0x05: 50Hz Data Rate, 0x06: 100Hz Data Rate(default) Note: The 5Hz Data Rate means that 5 times of data is automatically output every second. Sending other names should be done in the question and answer mode (automatic mode is to continuously output the current angle of the axis according to the specific frequency, and it is easier to see other commands in the answer mode. value). Bewis SensinglTechnologyiLLCl
Open the catalog to page 88) Inclinometer sensor automatically outputs the angle When the sensor is set to automatic mode output, there will be an angle output after the sensor is powered on. Default is automatic mode. Note: The default standard CAN-ID is 0x580+05 and the maximum is not more than 7FF. Here we revise'580' in '0x580+05', 05 can be modified through the front nodes. After revise, the CAN-ID will become 0xXHXL+0x05 when re-powered on. For example, send the data: 605 40 71 10 00 01 23 00 00, the CAN-ID will become 123+5=128 when it is repowered on. Bewis SensinglTechnologyiLLCl
Open the catalog to page 91 2) Set the extended address of CAN-ID We need to divide the address into two when setting the address of extended CAN-ID. First send high 16 address, then send the low 16 address. The CAN-ID address will change into new one (here the CAN-ID address we receive do not need to add the nodes) after being re-powered on. The maximum can not be more than 7FFFFFF. The default is 0x18fa0216. I Set high 16 extended address of CAN-ID Note: Low 16 address can not surpass FFFF. For example, send the data respectively as follows, 605 40 72 10 00 01 23 00 00 and 605 40 73 10 00 45 67 00 00. CAN-ID will...
Open the catalog to page 10BWK 225S Low Cost Dual-Axis CAN Output Inclinometer Executive standard ● Enterprise Quality System Standard: ISO9001:2008 Standard (Certificate No.10114Q16846ROS) ● CE certification (certificate number: 3854210814) ● RoHS (certificate number: G190930099) Bewis Sensing Technology LLC
Open the catalog to page 11Wuxi Bewis Sensing Technology LLC Address: Building 30, No. 58 Xiuxi Road, Binhu District, Wuxi City, Jiangsu Province, China Tel/Whatsapp: +86 189 2129 2620 Email: support@bwsensing.com Website: www.bwsensing.com
Open the catalog to page 12All Wuxi Bewis Sensing Tecnology LLC catalogs and technical brochures
-
GI320
25 Pages
-
BWSENSING BWK217S
8 Pages
-
AH100C
9 Pages
-
LoRaWAN G500 Gateway
1 Pages
-
LoRaWAN G200 Gateway
1 Pages
-
BWSENSING BWS5000E
14 Pages
-
BWSENSING Catalog 2020
60 Pages
-
BWSENSING BWK228
13 Pages
-
BWSENSING BWK218
12 Pages
-
BWSENSING BWK220
13 Pages
-
BWSENSING BWK210
13 Pages
-
BWSENSING BWK227S
13 Pages
-
BWSENSING BWK226S
13 Pages
-
BWSENSING BWK216S
12 Pages
-
BWSENSING BWK215S
12 Pages
-
BWSENSING BWL320
13 Pages
-
BWSENSING BWL328
13 Pages
-
BWSENSING BWL318
12 Pages
-
BWSENSING BWL310
13 Pages
-
BWSENSING BWL327S
13 Pages
-
BWSENSING BWL326S
13 Pages
-
BWSENSING BWL325S
12 Pages
-
BWSENSING BWL317S
12 Pages
-
BWSENSING BWL316S
12 Pages
-
BWSENSING BWL315S
12 Pages
-
BWSENSING BWN460
12 Pages
-
BWSENSING BWN428
13 Pages
-
BWSENSING BWN427
13 Pages
-
BWSENSING BWN425
12 Pages
-
BWSENSING BWN420
13 Pages
-
BWSENSING BWM460
12 Pages
-
BWSENSING BWM427
13 Pages
-
BWSENSING BWM426
13 Pages
-
BWSENSING BWM425
12 Pages
-
BWSENSING BWM420
13 Pages
-
BWSENSING BWM418
12 Pages
-
BWSENSING BWM417H
12 Pages
-
BWSENSING BWM417
12 Pages
-
BWSENSING BWM416
12 Pages
-
BWSENSING BWM415
12 Pages
-
BWSENSING BWM410
12 Pages
-
BWSENSING BWH528
14 Pages
-
BWSENSING BWH527
13 Pages
-
BWSENSING BWH526
14 Pages
-
BWSENSING BWH525
12 Pages
-
BWSENSING BWH520
14 Pages
-
BWSENSING BWH518
13 Pages
-
BWSENSING BWH517
12 Pages
-
BWSENSING BWH516
13 Pages
-
BWSENSING BWH515
12 Pages
-
BWSENSING BWH510
13 Pages
-
BWSENSING BWS5500
12 Pages
-
BWSENSING BWS4800
14 Pages
-
BWSENSING BWS5700
13 Pages
-
BWSENSING BWS2500
12 Pages
Archived catalogs
-
BWSENSING BWN426
13 Pages