BWH 526 High Precision Dual-Axis Digital Output Inclinometer Technical Manual
Open the catalog to page 1High Precision Dual-Axis Digital Output Inclinometer Introduction Designed by Bewis Sensing Technology LLC, BWH526 is a high precision dual-axis digital output inclinometer with MEMS technology. It has a measuring range of ± 30° and the highest accuracy of 0.003°. It is a cost-effective product. The product has automatic compensation and filtering algorithms to reduce errors caused by environmental changes. This product adopts the principle of non-contact measurement. It measures the change of static gravitational field and converts it into angle change. The change directly outputs the current...
Open the catalog to page 2BWH 526 High Precision Dual-Axis Digital Output Inclinometer Electrical Specifications Parameters Conditions Min Typical Max Units Operating current Non-loaded 20 30 40 mA Performance Specifications Measuring range(°) Measuring axis Conditions Vertically Indoor Completely stationary Zero temperature drift(°/C) Cross axis error(°) Power-on time Frequency response (Hz) Baud rate MTBF Electromagnetic compatibility Insulation resistance Shock resistance Weight (g) According to GBT17626 >100 MQ 2000g,3times/axis 320 ( Metal connector)/350 ( Aviation connector) Resolution: The measured minimum change...
Open the catalog to page 3High Precision Dual-Axis Digital Output Inclinometer Mechanical Characteristic Connector Metal connector Protection level Shell material Magnesium alloy anodizing Package size Product Size:L103.8*W55.4*H26(mm) Bare plate product size Product size: L68*W48*H12(mm) Note: ±1mm error for length and width dimensions, please refer to actual size. 63 Bewis Sensing Technology LLC
Open the catalog to page 4High Precision Dual-Axis Digital Output Inclinometer Installation direction The correct installation method can avoid measurement error. The following points should be made when installing the sensor: First of all, to ensure that the sensor mounting surface and the measured surface completely close, the measured surface should be as horizontal as possible, can not have the angle shown in Figure A and Figure C, the correct installation is shown in Figure B and Figure D. B uneven surface generates the angle D uneven surface generates the angle Secondly, the bottom cable of the sensor and the axis...
Open the catalog to page 5BWH 526 High Precision Dual-Axis Digital Output Inclinometer Electrical interfaces Cable color & Function RS 485 wiring diagram ■•^RE D VCC ^YELLOW TXD RS 232 wiring diagram Bewis SensinglTechnologylLLCP
Open the catalog to page 6High Precision Dual-Axis Digital Output Inclinometer Debug software Users can directly download serial assistant on official website (Supports-Download). You can also use more convenient and intuitive PC software. BWH526 supporting serial debugging software can be connected to the inclinometer on the computer for angle display. The software debugging interface is as shown in the figure below. Using the debug software, it can conveniently display the current X-direction tilt angle, and you can also modify and set other parameters by yourself. Software use steps: ① Correctly connect the inclinometer...
Open the catalog to page 7Protocol IData Frame Format: (8 data bits,1 stop bit,No parity check,default baud rate 9600) Identifier Frame Length Address Code Command Data Checksum (Ibyte) (Ibyte) (Ibyte) (Ibyte) (Nbyte) (Ibyte) 0x77 Data Format: Hexadecimal(The following command interprets Table 0X as a hexadecimal identifier. You do not need to enter 0X, such as 0x77, you only need to enter 77.) Identifier: Fixed to 77 Frame Length: Length from Frame Length to Checksum(included) Address Code: Address of acquiring module, default 0x00 Data: Content and length variable according to Command Checksum: Sum of Frame Length,...
Open the catalog to page 8|dentifier Frame Length Address Code Command Data Checksum (1byte) (Ibyte) (Ibyte) (1byte) (0byte) (Ibyte) Command response: Identifier (Ibyte) Frame Length Address Code Command (Ibyte) (Ibyte) (Ibyte) Checksum (Ibyte) Three groups SXXX.YYYY The data field contains 12 bytes, which are the X-axis, Y-axis and reserved bit angle values. The compressed BCD code is a group of four bytes. For example, the return command is 77 10 00 84 00 23 24 80 10 22 99 30 00 00 00 00 56, where X is 00 23 24 80 and Y is 10 22 99 30. For the four bytes of the return value for each angle, the format is SX XX YY YY,...
Open the catalog to page 9|dentifier Frame Length Address Code Command Data Checksum (1byte) (Ibyte) (Ibyte) (1byte) (Obyte) (Ibyte) Command response: Identifier Frame Length Address Code Command Data Checksum (1byte) (Ibyte) (Ibyte) (Ibyte) (8byte) (Ibyte) The data field contains 8 bytes, which are the X-axis and the Y-axis g value, which are compressed BCD codes, and each four bytes is a group. For example, the return command is 77 0C 00 54 10 01 94 56 00 01 01 20 7D, where X is 10 01 94 56 and Y is 00 01 01 20. For each g value return value of four bytes, the format is SX YY YY YY, S is the sign bit (0 positive, 1...
Open the catalog to page 10Identifier Frame Length Address Code Command Data Checksum Command response: Identifier Frame Length Address Code Command Data Checksum (Ibyte) (1byte) (Ibyte) (Ibyte) (Ibyte) (Ibyte) Note: For data, 00: 2400, 01: 4800, 02: 9600, 03: 19200,05: 115200,Default 02:9600. Note: Set baud rate to 115200 in high speed mode. When the Set baud rate command is executed successfully, the command response will be return in the original baud rate and then communicate with new baud rate. Note: If high frequency output is required, set the baud rate to 115200.If high frequency output is required, set the baud...
Open the catalog to page 11Identifier Frame Length Address Code (Ibyte) (Ibyte) (Ibyte) Command Data Checksum Command response: Identifier Frame Length Address Code C0mmand Data Checksum (Ibyte) (Ibyte) (1byte) (Ibyte) (Ibyte) (Ibyte) Note: absolute zero: Based on the factory-calibrated zero point. relative zero: Reference to the zero after the current installation. Identifier Frame Length Address Code (1byte) (1byte) (1byte) Command Data Checksum Command response: Identifier Frame Length Address Code Command Data Checksum Command response: Identifier Frame Length Address Code C0mmand Data Checksum Note: If Save setting...
Open the catalog to page 125 Pages
4 Pages
5 Pages
25 Pages
8 Pages
9 Pages
1 Page
1 Page
14 Pages
60 Pages
13 Pages
12 Pages
13 Pages
13 Pages
13 Pages
13 Pages
12 Pages
12 Pages
12 Pages
13 Pages
13 Pages
12 Pages
13 Pages
13 Pages
13 Pages
12 Pages
12 Pages
12 Pages
12 Pages
12 Pages
13 Pages
13 Pages
12 Pages
13 Pages
12 Pages
13 Pages
13 Pages
12 Pages
13 Pages
12 Pages
12 Pages
12 Pages
12 Pages
12 Pages
12 Pages
14 Pages
13 Pages
12 Pages
14 Pages
13 Pages
12 Pages
13 Pages
12 Pages
13 Pages
12 Pages
14 Pages
13 Pages
12 Pages
13 Pages