Mess-, Steuer- und Regelgeräte GmbH Copyright© 2009 WUNTRONIC GmbH. All Rights Reserved Heppstrasse 30 D - 80995 München Tel. +49 (89) 313 30 07 Fax +49 (89) 314 67 06 http://www.wuntronic.de e-mail: WUNTRONIC@wuntronic.de Server Monitoring, 19” and 1U for Temperature Humidity and Pressures with TC/IP Ethernet Interface and Relay Outputs Model H4531R, H3531R, H7531R Server monitoring system is designed for 19-inch rack mounting, the height is one rack unit - 1U. Model H4531R is prepared for connection of external Pt1000 temperature probe and models H3531R, H7534R are equipped with 1 meter temperature + humidity probe. Unit also contains three binary inputs for detection of two-state events - e.g. power presence, water, smoke, airflow, glass break detection, door contact Rack unit provides 5Vdc and 12dc power supply for external all sensors and detectors. Large dual line LCD for simultaneous display of temperature, humidity is an advantage. Parameters are easy adjustable from transmitter keyboard or from the computer. State-of-the-art capacitive polymer sensor ensures excellent calibration long term stability, inertia against water and condensation . Environmental monitor is equipped with two relay outputs for alarm indication or control of external devices. Each relay can be assigned to any measured value. „hƒn 19” Server Monitoring System with 1U „hƒnThe TC/IP Transmitters measures Temperature, Humidity, Pressure „hƒnLarge dual line display „hƒnAlarm functions by traps, syslog, www pages emails or SMS „hƒnBinary Inputs „hƒnRelay Outputs „hƒnTraceable calibration Certificate include (regarding EN ISO/IEC 17025 standard) „hƒnLong term stability of parameters „hƒnEasy to use, for example with Internet Explorer „hƒnFree TSensor configuration Software „hƒnFree SensorRead Software (for logging data to the PC Harddisk) Features: Description: „hƒn server and computer rooms „hƒn data centers „hƒn rack monitoring „hƒn industrial Ethernet „hƒn building management and automation „hƒn telecommunication devices Applications: Server Monitoring for Temperature, (Transmitter) Model H4531R with ext. Pt1000 Sensor input Sensor not include please select a pt1000 Sensor Order No. W23-304-115 This kind of transmitter are alos known as: industrial Ethernet, remote server environment monitoring, computer room monitor, data center thermometer, temperature humidity IP sensor, computer room temperature alert. Selection of our different Transmitters for Temperature, Humidity, Barometric Pressure with Binary Inputs an Relays Outputs Server Monitoring for Temperature, Humidity, Barometric Pressure (Transmitter) Model H7531 with ext. Sensor Order No. W23-304-130 (1 meter) W23-304-132 (2 meter) W23-304-134 (4 meter) Sensor cable length of 1, 2 or 4 meter available Communication: „hƒn Modbus TCP „hƒn Telnet „hƒn www pages „hƒn SNMP „hƒn SOAP Relay Outputs: „hƒn GSM voice dialer „hƒn Fan „hƒn Siren „hƒn Beacon Alarms: „hƒn e-mail „hƒn e-mail to SMS „hƒn www pages „hƒn SNMP „hƒn syslog Binay Inputs: „hƒn Power - UPS „hƒn Flood „hƒn Smoke „hƒn Door „hƒn And so on….. Inputs: „hƒn Temperature „hƒn Humidity „hƒn Pressure Server Monitoring for Temperature, Humidity, (Transmitter) Model H7531R with ext. Sensor Order No. W23-304-120 (1 meter) W23-304-122 (2 meter) W23-304-124 (4 meter) Sensor cable length of 1, 2 or 4 meter available Rack Server monitoring - Front view - Server Rack monitoring - Rear view -
Open the catalog to page 1
Temperature, Humidity and Pressure Transmitters with Binary Inputs and Relay Outputs Series HxxxR Picture Order No. Model Description W23-304-115 H4531R Temperature Transducer / Transmitter for external probe with Pt1000 sensor (not included), accuracy of the input without probe +/-0,2° Measured value Temperature and 3 binary inputs Maximum measuring ranges -200°C to 600°C (1 meter) W23-304-120 (2 meter) W23-304-122 (4 meter) W23-304-124 H3531R Temperature, Humidity Transducer / Transmitter T+RH probe with 1m cable. Cable lengths 2m or 4m available optionally. Humidity values available also...
Open the catalog to page 3
Accessories for the Temperature, Humidity and Pressure Transmitters Series T Picture Order number Model Description W23-101-103 SP008 AC voltage presence sensor, connectable to binary Hx531 inputs W23-101-105 LD63HS Water leakage sensor LD63HS, relay output, connectable to binary Hx531 inputs. Included cable 1.4 meters to water leakage sensor. Included cable 1.9 meters for connection of Hx531R. W23-101-170 PP90 right-angled stain-less steel flange for wall mounting W23-101-150 SD212SP Optical smoke detector, relay output, connectable to binary Hx531 inputs, powered from Hx531 12Vdc output....
Open the catalog to page 4All WUNTRONIC GmbH catalogs and technical brochures
-
Universal Heat Flow Sensors
2 Pages
-
Reference Magnet series MT
2 Pages
-
USB Gauss / Tesla Meter
8 Pages
-
CobraMax CompuScope Family
4 Pages
Archived catalogs
-
Transmitter
4 Pages
-
Accelerometer
2 Pages
-
Pulse Generator
2 Pages
-
Data Logger
7 Pages
-
Frequency Counter
5 Pages