1. Catalogs
  2. WUNTRONIC GmbH
  3. Frequency Counter

Frequency Counter

Frequency Counter

Frequency Counter

Product catalog summary
Features
  • Eight frequency counter channels with a range from 0.06 Hz to 100 kHz.
  • Supports differential and TTL inputs with a differential input range of 20 mV to 20 V.
  • Programmable SAC/DC differential inputs and observation window from 1 ms to 1.025 sec.
  • Precision time base with 1 ppm stability from 10°C to 50°C.
Typical Applications
  • Monitoring RPM from shafts in automotive and aircraft engines.
  • Monitoring flow meters and general-purpose frequency counting.
General Description

The P635 is a single-width, 3U, PXIbus module with eight frequency measurement channels. It features unique circuitry for monitoring a wide range of frequencies without changing module settings. It includes TTL inputs and differential input circuits with filtering and hysteresis for high noise immunity. The module supports AC or DC coupling of differential inputs on a per-channel basis.

Basic Circuit Operation

The module supports analog and TTL signal sources, with differential analog input paths for high noise immunity. The internal clock can be set to 1 MHz or 10 MHz, affecting the frequency measurement range and resolution. The observation window is programmable from 1 ms to 1.024 s, affecting counting accuracy and update speed.

Software

The P635 includes a Plug and Play driver and application examples for configuration and use. The user interface allows for starting/stopping acquisition, setting input ranges, and configuring various input and clock settings.

Specifications
  • Inputs: 8 channels, differential and TTL, with programmable coupling and impedance.
  • Frequency measurement range: 0.06 Hz to 100 kHz (1 MHz clock) or 0.6 Hz to 100 kHz (10 MHz clock).
  • Filtering: Programmable single-pole, low-pass RC type with a 50 kHz cutoff frequency.
  • Time Base: 1 MHz or 10 MHz clock rate, with ±1 ppm stability.
  • Environmental: Operational temperature range 0°C to +50°C, storage -25°C to +75°C, and relative humidity 0 to 85% non-condensing.
Ordering Information

Model P635-AA21: 8-channel, 100 kHz Frequency Counter.

See more

Catalog excerpts

Frequency Counter-1

The P635 is a single-width, 3U, PXIbus module with eight frequency measurement channels. This counter module can be used to monitor a variety of pulse sources. Moreover, its unique circuitry allows the monitoring of a wide range of frequencies without changing any module settings. > Monitoring shaft encoders and other devices to measure RPM from shafts on automotive and aircraft enginesMonitoring flow meters General-purpose frequency counting Eight frequency counter channelsՕ Frequency range from 0.06 Hz to 100 kHz Differential and TTL inputs provided Օ Differential input range 20 mV to 20 V Programmable SAC/DC differential inputs Օ Programmable observation window: 1 ms to 1.025 sec Precision time base ( 1 ppm, 10 > O C to 50 > O C) >

 Open the catalog to page 1
Frequency Counter-2

The P635 is a single-width, 3U, PXIbus module with eight frequency measurement channels. This counter module can be used to monitor a variety of pulse sources. Moreover, its unique circuitry allows the monitoring of a wide range of frequencies without changing any module settings. TTL inputs are provided as well as differential input circuits with filtering and hysteresis to provide high noise immunity. The switching threshold is programmable, and the input voltage should be at least twice the threshold voltage for noise immunity. AC or DC coupling of the differential inputs is programmable on...

 Open the catalog to page 2
Frequency Counter-3

SOFTWARE > The P635 comes with a Plug and Play driver and application examples for configuring and using the device. APPLICATION EXAMPLE > The following shows the user interface for an application example provided with the P635. This example demonstrates the capability of the P635 and provides a convenient utility for module verification. From this application example, the user has the following capability: Start and Stop AcquisitionՕ Set the input full scale range on a global basis Set the Window Clock time Օ Enable/Disable Health check Set inputs to AC or DC coupling on a global basis Օ Set...

 Open the catalog to page 3
Frequency Counter-5

900 N. State St.Lockport, IL 60441-2200 Toll-Free (US and Canada): phone 1-800-DATA NOW 1-800-328-2669 Direct: phone +1-815-838-0005 fax +1-815-838-4424 Email: [email protected] find your local sales representative or distributor or to learn more about KineticSystems products visit: www.kscorp.comORDERING INFORMATION > MODELDESCRIPTION P635-AA21 8-channel, 100 kHz Frequency Counter Updated May June 13th, 2005 Copyright ҩ 2005 KineticSystems Company, LLC. All rights reserved.

 Open the catalog to page 5

All WUNTRONIC GmbH catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.