16 channel Data Logger without Display
8Pages

{{requestButtons}}

Catalog excerpts

16 channel Data Logger without Display - 1

UNIVERSAL MONITORING SYSTEM MS5D, MS5 COMPLETE SOLUTION FOR MONITORING OF TEMPERATURE, HUMIDITY, PRESSURE AND OTHER VALUES IN THESE FIELDS: Food and beverages industry (HACCP) Pharmaceutical industry Blood stations, pharmacies Horticulture and cultivation of plants HVAC (heating, ventilation, air conditioning, cooling Building and energy management Research and development Laboratories (GLP) Sixteen channel dataloggers are designed for recording of values from transducers of variety of quantities, alarm state indication, and process control. Parameters of inputs are defined by the types of installed input modules. Datalogger with transducers configured accordingly to client order can measure analog signals, frequency, count impulses, evaluate two-state quantities and read data from devices compatible with ADAM Advantech protocol (ModBus is under preparation). Data is ready to download to a personal computer anytime via USB, RS232, RS485, Ethernet or GSM modem. Analyzing of the record is enabled after data download to the PC by means of the included program. NEW FIRMWARE AND SOFTWARE ENABLE ESPECIALLY TO: Configure individually each input channel for measurement, alarm evaluation and data logging, including individual logging interval for each input. Each input channel can be individually programmed for different modes of record (continuous record, time dependent record, record only if specified logic conditions are matched, record triggered by external signal, etc.). It is enabled to record with shorter interval in case, measured values match previously defined conditions e.g. to map in detail trouble state. It is also enabled to memorize actual value and time if defined time event appears. Set up to four different logic conditions for each channel to activate alarm. Each condition compares measured values from inputs with set limits. It is possible to set hysteresis and delay of condition validity. Also weekly program can be set and distant condition from the PC. Indicate alarm states - visually, audibly, by relay contact, by e-mail or SMS message. Control processes by means of the optional relay module enabling to switch 16 output relays depending on alarm states. Receive information from data logger by means of SMS messages via GSM modem - actual values, alarms, memory occupation and other. Assign to each input channel name of actual recorded process to identify monitored object (e.g. type of monitored product). It is enabled to select this name from data logger keyboard during the operation. Store several configuration profiles (all logger parameters setting) for different measuring tasks and select profiles from MS5D logger keyboard or optional external terminal. Change easily input modules if different input signals are required for measurement. To connect input signals easily to removeable terminal connector. Each input channel is equipped with three terminals including shielding. Following data loggers are available: MS5D - completely equipped data logger Ordernumber - dual line alphanumeric LCD display W07-090-110 - four control buttons - 32 alarm LEDs - all functions as MS5D data logger - without dual line alphanumeric LCD display - without control buttons - without 32 alarm LEDs - common alarm indication with one LED

Open the catalog to page 1
16 channel Data Logger without Display - 2

UNIVERSAL MONITORING SYSTEM MS5D, MS5 ARCHITECTURE OF MONITORING SYSTEM: - ANALOG oGHr GSM MODEM - SMS - E-MAIL, SNMP TRAP - PHONE DIALER - $.867,6&+(0 6,*1$L PHONE DIALER CONTROLLED DEVICE CONTROLLED DEVICE interior temperature, humidity, pressure CONTROLLED DEVICE temperature, humidity, pressure probe temperature transducer temperature, humidity, pressure probe temperature transducer

Open the catalog to page 2
16 channel Data Logger without Display - 3

UNIVERSAL MONITORING SYSTEM MS5D, MS5 TYPE MEASURED VALUE dc current 4 to 20 mA A0 dc current 4 to 20 mA dc current 0 to 20 mA dc current 0 to 1A dc current 0 to 5A ac current 0 to 20mA ac current 0 to 1A ac current 0 to 5A dc voltage 0 to 100mV dc voltage 0 to 1V dc voltage 0 to 10V dc voltage -10 to +10V dc voltage +75V ac voltage 0 to 100mV ac voltage 0 to 1V ac voltage 0 to 10V ac voltage 0 to 50V measurement of resistance input for Nickel RTD temperature sensor Ni1000, 6180 ppm/°C, range -50 to +250°C input for Platinum RTD temperature sensor Pt100, range -140 to +600°C input for...

Open the catalog to page 3
16 channel Data Logger without Display - 4

UNIVERSAL MONITORING SYSTEM MS5D, MS5 PROGRAM FOR PERSONAL COMPUTER Setting of all system parameters and the stored data processing is performed by the PC software for Windows. Included software - freeware is possible to download free from www.cometsystem.cz. It enables to communicate with logger through a serial RS232 link or through an RS485 network (long distance or several networked loggers), via USB, by means of modems (line or GSM) or via optional Ethernet interface. It also enables to configure the logger, read recorded values and display actual values of the inputs. It is possible...

Open the catalog to page 4
16 channel Data Logger without Display - 5

UNIVERSAL MONITORING SYSTEM MS5D, MS5 Terminals for input signal connection - each input has three terminals including shielding Included accessory: Traceable calibration certificate from the manufacturer, instruction manual. Calibration certificate with declared metrological traceability of etalons is based on requirements of EN ISO/IEC 17025 standard. Included is also communication cable for RS232 2meters long, free Windows program (also downloadable for free from www.cometsystem. cz). Program enables to read recorded values and display actual values of the inputs. It is possible to view...

Open the catalog to page 5
16 channel Data Logger without Display - 6

UNIVERSAL MONITORING SYSTEM MS5D, MS5 Ordernumber Optional internal equipment: W07-101-300 Built-in independent SMS port for GSM modem connection for SMS reception and sending. Enables to receive information from data logger by means of SMS messages - actual values, alarms, memory occupation and others - as a response to SMS query from user or in case of alarm creation at data logger. Not necessary, if data logger is connected to the PC via GSM modem. Built-in LAN interface for data logger connection to Ethernet network. In case of limits exceeding alarm is activated and warning e-mail or...