Wuhan UHV Power Technology Co.,Ltd.
Open the catalog to page 1Wuhan UHV Power Technology Co.,Ltd. UHV-406 Circuit Breaker Analyzer (High Voltage Switch Mechanical Characteristics Tester) provides convenience for dynamic analysis of various circuit breakers, and can accurately measure the mechanical dynamic characteristic parameters of high voltage circuit breakers of various voltage levels such as low oil, high oil, vacuum, sulfur hexafluoride, etc. High voltage circuit breakers are responsible for the dual tasks of control and protection in the power system, and the quality of their performance is directly related to the safe operation of the power system....
Open the catalog to page 2Wuhan UHV Power Technology Co.,Ltd. 8. Equipped with 2 USB interfaces, the instrument can be connected to a mouse to operate the instrument, and the data can be directly saved to a USB flash drive and uploaded to a computer for analysis and storage. RS232 interface online operation is optional, and wireless tablet operation is optional. 9. It can simultaneously measure 12 metal contact breaks, 6 main breaks and 6 auxiliary breaks, 3/6 closing resistances, 1 speed (3 speeds optional), and 3/6 double-end grounding measurements (3 and 6 induction methods optional). Accelerometers, digital sensors,...
Open the catalog to page 3Wuhan UHV Power Technology Co.,Ltd. Opening (closing) different phases between phases Closing resistance input time, resistance value 3. Measurement range: 30~10KQ, resolution 0.1 Q, accuracy: ^1% + 1 Q 4. Speed measurement: Initial opening (closing) speed Average speed in a specified time period (travel section or angle section) 5. Speed measurement range: 0.1mm sensor 0.01~25.00m/s, accuracy: ±0.1m/s 345° angle sensor 0.01~25.00m/s, accuracy: ±0.1m/s Laser sensor 0.01 ~15.00m/s. 6. Stroke measurement: moving contact stroke (3-way stroke measurement optional) Contact stroke (opening distance)...
Open the catalog to page 4Wuhan UHV Power Technology Co.,Ltd. 11. DC power output: DC6~270V continuously adjustable, DC24V^25A (short time), DC220V^ 20A (short time). 12. External trigger voltage: AC/DC10-300V, current ^120A 13. Isolating switch measurement range: (1) , voltage output: DC6~270V (adjustable); (2) , power output time: 0.01-20 seconds (settable); (3) , the maximum acquisition time of the break signal is 200 seconds; (4) , can measure the break closing and opening time, three-phase different phases, bounce time and number of times 14. Main unit volume: 400X300X 175mm
Open the catalog to page 57 Pages