Overview: The WS102 Series comprises industrial-grade water-quality sensors for continuous, real-time monitoring of chemical and physical parameters. These sensors are applicable in drinking-water treatment, wastewater management, aquaculture, industrial process control, and environmental monitoring. They are designed with rugged construction, automatic temperature compensation, and dual outputs for integration with SCADA, PLC, and IoT systems.
Key Features:
  • Rugged & Reliable: IP68 protection, wide temperature ranges, and low-power operation for harsh conditions.
  • Real-Time Data & Control: Provides immediate feedback for process optimization and rapid incident response.
  • Easy Integration: Standard RS-485 Modbus RTU and optional 4–20 mA outputs for easy connection to various systems.
  • Low Maintenance: Automatic self-cleaning in some models reduces service intervals.
Model Highlights:
  • WS102-PH: Measures pH levels for chemical balance and corrosion prevention.
  • WS102-DOS: Monitors dissolved oxygen for aeration control and aquatic health.
  • WS102-ORP: Indicates disinfectant effectiveness and oxidation state.
  • WS102-CL: Tracks residual chlorine for disinfection verification.
  • WS102-EC: Measures electrical conductivity for water purity and salinity management.
  • WS102-BRM: Controls bromine levels for industrial disinfection.
  • WS102-TDS: Gauges total dissolved solids for filtration efficiency.
  • WS101-OTB: Detects suspended solids and monitors water clarity.
  • WS102-COD: Quantifies organic pollution with low maintenance.
  • WS104-TN: Measures total nitrogen for nutrient pollution control.
  • WS101-LL: Monitors liquid levels with high accuracy.
Connectivity Options:
  • Direct connection to PC, HMI, or PLC for local monitoring.
  • LoRaWAN and LTE gateways for cloud or remote server data transmission.
  • WiFi and LTE gateways for flexible remote monitoring.
Technical Specifications:
  • Power Supply: DC10-30V (recommended 12V).
  • Pressure Range: Varies by model, up to 400KPa.
  • Shell Material: Varies by model, including PPS, PC+316L, and stainless steel.
  • Protection Grade: IP68.
  • Output: RS485 (Modbus RTU) and 4–20 mA.
Installation and Wiring:
  • Follow instructions carefully to avoid damage.
  • Ensure correct wiring before powering on.
  • RS485 lines must not contact the power supply line.
Sensor Specifics:
  • Residual Chlorine Sensor (WS102-CL): Measures residual chlorine levels with built-in temperature compensation and dual signal outputs.
  • Electrical Conductivity Sensor (WS102-EC): Monitors electrical conductivity with automatic temperature compensation and dual signal outputs.
  • Bromine Level Sensor (WS102-BRM): Measures bromine levels with automatic temperature compensation and dual signal outputs.
  • Total Dissolved Solids Sensor (WS102-TDS): Measures TDS with automatic temperature compensation and dual signal outputs.
  • Turbidity and Total Suspended Solids Sensor (WS102-OTB): Measures turbidity and TSS using a fiber-optic nephelometric design, compliant with ISO 7027 standards.
Communication Protocol:
  • All sensors use Modbus RTU protocol with a default baud rate of 9600bps.
  • Supports seamless integration with SCADA, PLC, or IoT platforms.
General Recommendations:
  • Ensure proper wiring to avoid damage to the sensors.
  • Follow the provided guidelines for installation and maintenance to ensure accurate measurements and long-term reliability.
  • Utilize the automatic cleaning features where applicable to maintain sensor performance.
See more

Catalog excerpts

Water Quality Sensor pH, DOS, ORP, EC, CL, TDS, TSS, CSD-1

Water Quality Analysis Sensors

 Open the catalog to page 1
Water Quality Sensor pH, DOS, ORP, EC, CL, TDS, TSS, CSD-2

WS-102 Series WS102 Series is a unified family of intelligent, industrial-grade water-quality sensors engineered for continuous, realtime monitoring of critical chemical and physical parameters. Each model combines rugged construction, automatic temperature compensation, and dual outputs (RS-485 Modbus RTU and/or 4-20 mA) for seamless SCADA, PLC, and IoT integration, enabling precise process control, regulatory compliance, and early detection of water-quality issues in applications ranging from drinking-water treatment and municipal wastewater management to aquaculture, industrial process control,...

 Open the catalog to page 2
Water Quality Sensor pH, DOS, ORP, EC, CL, TDS, TSS, CSD-3

Flexible Connectivity Options 1) Sensor Connects to PC/HMI/PLC Connect the sensor directly to a PC, HMI, or PLC for local monitoring and control. 2) Sensor Connects to Private LoRa to PC/HMI/PLC For long-range private LoRa communication to a local control system Private LoRa 3) Sensor Connects to LoRaWAN Gateway Sends data to a cloud or remote server via a LoRaWAN network 4) Sensor Connects to WiFi Gateway Provides wireless IP connectivity for SCADA or IoT platforms 24VDC Power Supply 5) Sensor Connect to LTE NBIoT Gateway SCB111-485-NB Enables low-power cellular data transmission to the cloud...

 Open the catalog to page 3
Water Quality Sensor pH, DOS, ORP, EC, CL, TDS, TSS, CSD-4

Water Quality Analysis PH Sensor Water Quality Analysis PH Sensor The WS102-PH is an intelligent water-quality analysis sensor designed for continuous, real-time pH measurement, a critical parameter for ensuring water safety, protecting equipment, and meeting environmental regulations. Accurate pH control safeguards drinking water quality, supports healthy aquatic ecosystems, optimizes chemical treatment efficiency, and prevents costly corrosion or scaling in industrial processes. Ideal for general and industrial water treatment, sewage processing, aquaculture, surface-water monitoring, environmental...

 Open the catalog to page 4
Water Quality Sensor pH, DOS, ORP, EC, CL, TDS, TSS, CSD-5

Features & Benefits Parity bit Address Description • Please follow the instructions carefully, the wrong wiring will damage the product completely. • Please carefully check all the wiring in the system and confirm that the wiring is complete right before switching on the power. • Note: RS48SA line and RS48SB line are strictly forbidden to contact the power supply line, otherwise the communication of the electrode will be permanently damaged. Electrode Outlet Information Model

 Open the catalog to page 5
Water Quality Sensor pH, DOS, ORP, EC, CL, TDS, TSS, CSD-6

Water Quality Analysis Dissolved Oxygen Sensor^ Water Quality Analysis Dissolved Oxygen Sensor WS102-DOS The WS102-DOS is an intelligent water-quality analysis sensor designed for continuous, real-time dissolved oxygen (DO) measurement, enabling immediate process control and optimized aeration for lower energy costs. Ideal for tap water monitoring, municipal and industrial wastewater treatment, aquaculture systems, and environmental field applications, it helps operators maintain regulatory compliance, protect aquatic life, and detect pollution events early. The sensor features a built-in temperature...

 Open the catalog to page 6
Water Quality Sensor pH, DOS, ORP, EC, CL, TDS, TSS, CSD-7

Features & Benefits Parity bit Address Description • Please follow the instructions carefully , the wrong wiring will damage the product completely. • Please carefully check all the wiring in the system and confirm that the wiring is complete right before switch on the power. • Note: RS48SA line and RS48SB line are strictly forbidden to contact with the power supply line, otherwise the communication of the electrode will be permanently damaged. Ordering Information Model

 Open the catalog to page 7
Water Quality Sensor pH, DOS, ORP, EC, CL, TDS, TSS, CSD-8

V^Water Quality Oxidation Reduction Potential Sensor^ Water Quality Analysis Oxidation Reduction Potential Sensor WS102-ORP The WS102-ORP is an intelligent water-quality analysis sensor designed for continuous, real-time oxidation-reduction potential (ORP) measurement, a key indicator of a water system’s disinfection effectiveness and overall chemical balance. Accurate ORP monitoring helps ensure proper chlorine dosing, supports pathogen control, and provides early warning of contamination or chemical imbalance, making it essential for safe drinking water, stable aquaculture environments, and...

 Open the catalog to page 8
Water Quality Sensor pH, DOS, ORP, EC, CL, TDS, TSS, CSD-9

Address Description • Please follow the instructions carefully, the wrong wiring will damage the product completely. • Please carefully check all the wiring in the system and confirm that the wiring is complete right before switching on the power. • Note: RS48SA line and RS48SB line are strictly forbidden to contact the power supply line, otherwise the communication of the electrode will be permanently Electrode Outlet Ordering Information Model

 Open the catalog to page 9
Water Quality Sensor pH, DOS, ORP, EC, CL, TDS, TSS, CSD-10

VWater Quality Analysis Residual Chloride Ion Sensor^ Water Quality Analysis Residual Chloride Ion (CL-) Sensor WS102-CL The WS102-CL is an intelligent water-quality analysis sensor designed for continuous, real-time residual chlorine (Cl") measurement, a critical parameter for verifying disinfection efficiency and ensuring safe, clean water. Accurate monitoring of free chlorine or hypochlorous acid (HOCl) levels helps operators maintain optimal disinfection in drinking water systems, industrial process water, and membrane-based treatments such as reverse osmosis, while preventing overchlorination...

 Open the catalog to page 10
Water Quality Sensor pH, DOS, ORP, EC, CL, TDS, TSS, CSD-11

Features & Benefits Parity bit Address Description • Please follow the instructions carefully , the wrong wiring will damage the product completely. • Please carefully check all the wiring in the system and confirm that the wiring is complete right before switch on the power. • Note: RS48SA line and RS48SB line are strictly forbidden to contact with the power supply line, otherwise the communication of the electrode will be permanently damaged. Ordering Information Model

 Open the catalog to page 11
Water Quality Sensor pH, DOS, ORP, EC, CL, TDS, TSS, CSD-12

\Water Quality Analysis Electric Conductivity Sensor^_ Water Quality Electric Conductivity Sensor WS102-EC . The WS102-EC is an intelligent water-quality analysis sensor designed for continuous, real-time electrical conductivity (EC) measurement, a key indicator of dissolved ion concentration and overall water purity. Accurate EC monitoring is essential for distinguishing between pure, spring, mineralized, and tap water, as well as for managing industrial processes, detecting pollution in sewage, and ensuring consistent water quality in purification or desalination systems. By providing immediate...

 Open the catalog to page 12

All WoMaster catalogs and technical brochures

  1. DS412/DP412

    9  Pages

  2. WR222 Series

    6  Pages

  3. DP612

    5  Pages

  4. DS612

    5  Pages

  5. MP614

    5  Pages

  6. DS306

    4  Pages

  7. DS406

    4  Pages

  8. DP406

    4  Pages

  9. DP406 series

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.