Industrial LoRa Controller LM200 I/O Tracking Controller Complete LoRa Controller for Analog IO Tracking The LM200 and LC144 utilize Low Power Wide Area (LPWA) technology to establish Modbus/RTU communication, addressing the needs of wireless IoT applications with long-distance coverage and minimal power consumption. In the LC144, various analog inputs and outputs are supported, encompassing voltage inputs and outputs, current inputs and outputs, PWM output, and a Modbus RTU slave RS-485 port. A single LM200 can connect up to 250 LC144 LoRa end nodes, facilitating two-way communications. LC144 nodes transmit field site analog signals to another LC144 through the LM200, achieving mirroring functionality. The LoRa wireless range can stretch up to 3-6KM, contingent on environmental conditions. LM100 and LC144 come with two variant models, LM100-900 / LC144-900 for adjustable EU868,AS923, KR920,US915 and LM100-400 / LC144-400 for EU433. The LM200 and LC144 offer remarkable flexibility in wireless IoT applications, enabling tasks like cable-free LED light control and reproducing analog signals at remote sites as a substitute for traditional wiring. Analog I/O Extension & Tracking by LoRa (LC144+LM200) • Transparent /Reproduce Analog Signal by LoRa • LM200 Polling Source LC100 specific Channel and Output to Target LC100 specific Channel • Create /Edit Tracking Rule by Utility Tool • Achieve 2-Sites Analog Tracking 0~10V Input / Output (LC144) • 2 Channels 0~10V High Impedance Input- Luminance Sensing • 1 Channel 0~10V Open Drain Output, Dimmer Control 4~20mA Input / Output (LC144) • 2 Channels Current Sensing, 0.3%High Accuracy • 1 Channel Current Output, 0.3% High Accuracy V / V, V / A, A / A Auto I/O Tracking (LC144 + LM200) • V / V Tracking – Local Input Voltage , Remote Output Voltage • V / A Tracking – Local Input Voltage, Remote Output Current in V/A Ratio • A / A Tracking – Local Input Current, Remote Output Current • A / V Tracking – Local Input Current , Remote Output Voltage in A/V Ratio • 20 I/O Rule Entries (Maximum) Secured & Reliable Radio Communication • ECHO & Re-Send Mechanism • AES 128 Data Encryption Communication Time-Out Output Control • Over-Polling Time Setting for Voltage and Current • Independent Voltage and Current Holding Output • Available when T/O Tracking Output Activate Event Log & Utility Monitoring (LM200) • 1K Event Log Entries – Polling Fail, Remote Control Fail • On-Line Monitoring by LoRaMAC Utility Industrial Application • 10~30V DC wide power range input • Low Power Consumption • Wide Coverage up to 6KM Windows© Configure Tools • User-Friendly, Model Auto Detection • -40 ~ 75°C / 90%H Operating Temperature / Humidity • Analog IO Parameter Read and Write • Compliance IEC 61000-6-2/-6-4 Heavy Industrial EMC
Open the catalog to page 1✓ Transparent LoRa Communication – Analog I/O Tracking mA 20 V 10 Tag Name (Rule Name) Tracking Rule - Input Tracking Rule -Output ✓ User Friendly LoRaMAC Utility to configure Analog IO parameters Easy Created Rule Chain V-V, V-A, A-A, A-V Ratio Control Single Input chains to Multiple Outputs Loop Delay Setting Network Disconnection – Holding V
Open the catalog to page 2Power Connector • V+, COM, Earth Ground Input Voltage 0~10V Positive Input Current 4~20mA Positive Input Voltage 0~10V Positive Input Current 4~20mA Positive Output Current 4~20mA Positive Output Voltage(OC) 0~10V Positive Output PWM Voltage 0~5V Positive Output PWM(OC) 0~10V Positive
Open the catalog to page 3Wireless Specification Frequency -900 model : Frequency Support EU 868Mhz, US915Mhz, AS 923Mhz, KR 920Mhz -400 model : Frequency Support EU 433Mhz Frequency adjust by Utility Wireless Technology Low Power Wide Area – LoRa MAC Technology Spreading Factor LoRa Demodulator Signal to Noise Ratio: -2.5dB ~ -20dB Operating Mode Modbus protocol over the Air (LoRa MAC Transparent Transmission) with configurable Echo time and retransmission technology LM200 supports Group I/O Tracking function, perform I/O Tracking between one pair of LC144 Forwarding Data Buffer 256Bytes FIFO Data Buffer for LoRa signal...
Open the catalog to page 4Frequency: 100Hz~1KHz with 0.2% Duty-Cycle Accuracy Output Type-1: 5V, 200mA (Max) Output Type-2: Open Collect (O.C.), 10V /200mA (Max) Power (On): System Power applied LoRa (Blinking): LoRa RF Signal on Communication Power Requirement Input Rating Typical DC 24V, Rating: 10~30V 3-Pins Removable Terminal Connector for V+ ,Com and Earth Ground Reverse Protection Power Consumption LM200: 1 Watt @ DC 24V power input LC144: 3 Watts @ DC 24V power input Mechanical Installation Enclosure Material Ingress Protection 26(D) x 102.5 (H) x 72 mm (W) / with wall mounting clip Environmental Operating Temperature...
Open the catalog to page 5LoRa /Modbus RTU Client Agent 1 x RS-485 Slave 2-wire, 1 x SMA Antenna Connector LM200-900: adjustable EU868,AS923, KR920,US915 frequency LoRa /Modbus RTU Client Agent 1 x RS-485 Slave 2-wire, 1 x SMA Antenna Connector LM200-400: EU433 LoRa End-Node, 8CH AIO, 1 Modbus RTU 485 Host 2 x 0~10V input, 0.2% accuracy 2 x 4~20mA input, 0.3% accuracy 1 x 0~10V Output, Open Collect (O.C.) Type, 0.2% accuracy 1 x 4~20mA Output, 0.3% accuracy 1 x PWM Output (0~5V), 200mA (max), 0.2%Duty_Cycle Accuracy @1khz 1 x PWM (0~10V), Open Collect (O.C.) Type, 200mA, 0.2% Duty Cycle accuracy @1Khz, 10V(Max) 1 x RS485...