Database to Raptor dimmer actuator double
8Pages

{{requestButtons}}

Catalog excerpts

Database to Raptor dimmer actuator double - 1

Raptor Dimmer actuator, double Application instructions Woertz AG Hofackerstrasse 47 Postfach 948 CH-4132 Muttenz 1 Tel. +41 61 466 33 33 Fax +41 61 461 96 06 info@woertz.ch www.woertz.ch

Open the catalog to page 1
Database to Raptor dimmer actuator double - 2

Application instructions "RAPTOR Dimmer actuator, double" (No. 49593...) 1. How does it operate? The double Dimmer actuator for electronic ballast of the RAPTOR series allows two independent dimm groups to be controlled. The main functions „On/Off“ and „Dimming“ can be completed with further functions when programming: stair lighting function and preset luminosity values. The behaviour at bus voltage failure and bus voltage return can be parameterised. Connection configuration: Version 49593G/Lx Version 49593W/Lx Max. operating voltage of actuator 230 VAC. Max. load current at both outputs...

Open the catalog to page 2
Database to Raptor dimmer actuator double - 3

The different functions are explained below on the base of the ETS3 Software. The database of the device can also run on ETS2 Software. Here you can select the main operating mode of the device. Different or advanced parameters are available according to the chosen mode. Output 1 Time tunclion Output 2 Time tunclion Function delay after bus voltage return (11.7 sec] State after bus return/Reset Relay behaviour at bus failure Output 1 ..1 0V activates mm. value State after bus return/Reset Relay behaviour at bus failure Output 1 ..1 [Tv* activates mm. value Interval (0, 17 s.) during which...

Open the catalog to page 3
Database to Raptor dimmer actuator double - 4

Identical menu for output 1 or 2. When loading the application following functions are available: Output 1 Time function Output 2 Time function Dimm range at output Dimm time factor 0..100% |Dirnm time =.1 ."3s x lector) Dimm down until lower dimm range Send dimmer status (ON/OFF) Send dimmer status [Dimm value) Cancel | | Default Help Defines the state when 1 is received at the switch Allows the analogue voltage value of the dimming range to be adapted for the different electronic Adjustment of the rate of change during dimming. Defines the state of the switch object via bus (0/1). Defines...

Open the catalog to page 4
Database to Raptor dimmer actuator double - 5

Output 1 Time function Output 2 Time function Output 1 Time function Time function only operative when driving via value object [Obj.Cl) when driving vie value object? [0bj.4] Factor tor stair light time Basis for stair light time stair Tight time - basis x factor Factor lor warning time before switching off B asis for warning: "tirrie bef ote switching off stair light time = basis K factor Luminosity during warning time Allows the operation mode of the stair lighting to be The time function may also be activated when receiving a value via value object. Otherwise the time function is only...

Open the catalog to page 5
Database to Raptor dimmer actuator double - 6

Number | Name | Object Function | Length UI\Q Output 1 Switch on/Status 1 bit Q^2 Output 1 Dimm function 4 bit □3 3 Output 2 Dimm function 4 bit Dfl6 Output 1 Luminosity preset (0/1) 1 bit □^7 Output 2 Luminosity preset (0/1) 1 bit

Open the catalog to page 6
Database to Raptor dimmer actuator double - 7

Window contact Drive for anti-glare device Wind sensor Fluorescent lamp ecobus combi Power current Output control voltage Switch actuator, double Type Gesis Type Winsta Shutter actuator, single Type Gesis Type Winsta Binary input, quadruple Dimm actuator, double Type Gesis Type Winsta Power Supply Media coupler

Open the catalog to page 7
Database to Raptor dimmer actuator double - 8

Application instructions "RAPTOR Dimmer actuator, double" (No. 49593...) 5. Specifications Standard Article number Connector type at output Output voltage Connector type at control voltage EMC: EN 50090-2-2 / Security: EN 60950-1 49593G/L1 (Phase L1) 49593G/L2 (Phase L2) 49593G/L3 (Phase L3) 49593W/L1 (Phase L1) 49593W/L2 (Phase L2) 49593W/L3 (Phase L3) 2 x 3 Pol gesis ® (female) 2 x 3 Pol WINSTA ® (female) 230VAC (output voltage cable) KNX connector Control voltage at output 2x1-10VDC (2 pole), can be set from 0V…9V up to 10V Load capacity per output ohmic load: 16A at 230VAC -1...

Open the catalog to page 8

All Woertz catalogs and technical brochures

  1. ATEX-Sortiment

    15 Pages

  2. FE180/E90

    12 Pages

Archived catalogs

  1. Junction Boxes

    19 Pages

  2. Screw terminals