Autoloop pro

Autoloop pro

Autoloop pro

Product catalog summary
Overview: The Autoloop PRO is a fully automatic carousel designed for flame sterilizing inoculation loops, suitable for up to four loops. It is developed to meet the needs of microbiological, cell biological, and biotechnological laboratories.
Design and Usability: The device features a stable housing for easy access and is suitable for both right and left-handed users. It includes a fully graphic display for easy function selection and precise control of flaming and cooling times.
Functionality: The Autoloop PRO automates the rotation and flaming process, displaying remaining times for both flaming and cooling. It prevents the use of hot loops by indicating when loops are cool and ready for use. An optional foot pedal allows for additional flame sterilization of other lab equipment.
Safety Features: The device includes a nearly perpendicular loop holder position to prevent contamination and an intelligent sensor to monitor sterilization safety. It also features temperature control, flame activation warnings, and a tilt sensor.
Efficiency and Durability: The precise control of sterilization times extends loop life and reduces gas consumption. The device is made from stainless steel and anodized aluminum, with a heat-resistant glass display, ensuring durability under extreme lab conditions.
Technical Specifications: The Autoloop PRO operates with a microprocessor and a fully graphic dot-matrix display. It supports 1-4 loop holders with optical detection, adjustable flame and cooling times, and optional foot pedal operation. Safety features include over-temperature protection and a sterilization monitor with adjustable intensity settings.
Additional Information: The package includes four loop holders, four loops, a pedestal, a foot pedal connector, and an instruction manual. It comes with a two-year warranty, excluding wear and tear parts. The device complies with CE and EEC guidelines.
Performance Comparison: The Autoloop PRO significantly reduces working time compared to traditional methods, offering up to 70% time savings.
See more

Catalog excerpts

Autoloop pro-2

Flammenzeit Sekundengenaue Einstellung der benötigten Flammensterilisationszeit Das vollautomatische Karussell zum Ausglühen von Impfösen. Flame time Precise settings of the required flame sterilization time Das Ösenkarussell Autoloop PRO , passend für bis zu 4 Impfösen, wurde nach aktuellen Bedürfnissen in Laboren der Mikrobiologie, Zellbiologie und Biotechnologie entwickelt. Moderne Konstruktion Das standsichere Gehäuse ermöglicht einen bequemen und einfachen Umgang mit Impfösen. Durch beidseitige Entnahmepositionen ist das Karussell für Rechts- und Linkshänder gleichermaßen geeignet. Mehr...

 Open the catalog to page 2
Autoloop pro-3

The fully automatic carrousel for flame sterilizing inoculation loops. Startmöglichkeiten Wahlweise direkter Start oder Sterilisation aller Impfösen durch eine Volldrehung The inoculation loop carrousel Autoloop PRO , which is suitable for up to 4 inoculation loops, was developed to comply with current requirements in microbiological, cellbiological and biotechnological laboratories. Start options Start immediately or sterilize all inoculation loops in a full rotation Modern design The stable housing enables comfortable and easy access to inoculation loops. Removal positions on both sides make...

 Open the catalog to page 3
Autoloop pro-4

mit 4 Impfösenhaltern 4 Impfösen Standfuß Fußpedalanschluss Bedienungsanleitung 2 Jahre Garantie Laborgasbrenner nicht im Lieferumfang enthalten includes 4 inoculation loop holders 4 inoculation loops Pedestal Foot pedal connector Instruction manual 2-year warranty Laboratory gas burner not included für Fuego SCS - Serie Art.-Nr. 8.000.400 for Fuego SCS - Series Art.-No. 8.000.400 für gasprofi 1 SCS micro - Serie Art.-Nr. 6.000.400 for gasprofi 1 SCS micro - Series Art.-No. 6.000.400 Technische Daten: Technik: Anzeige: Drehrichtung: Impfösenhalter: Einstellbare Ausglühzeit: Einstellbare Abkühlzeit:...

 Open the catalog to page 4
Autoloop pro-5

Speed-up Flame Sterilizing Inoculation Loops and Cut Down Your Costs! Case 1: Bunsen Burner & 1 Inoculation Loop Loop 1 4 sequences finished after 80 seconds Working with inoculation loop Flaming inoculation loop Time to exchange loops Cooling period Case 2: Fuego SCS & 4 Inoculation Loops placed on a Tray Loop 1 Loop 2 Loop 3 Loop 4 Case 3: Fuego SCS with Automated Caroussel Autoloop Pro & 4 Inoculation Loops Loop 1 (Optimized Flaming with Sterilization Monitor) Loop 2 Loop 3 Loop 4 Working with the Autoloop Pro (Case 3): • Save 70% working time compared to Case 1 • Save 40% working time compared...

 Open the catalog to page 5

All WLD-TEC GmbH catalogs and technical brochures

  1. SteriMax

    4  Pages

  2. Flame 100

    4  Pages

  3. Flame 110

    3  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.