Overview: The GAS FLOW CONTROLLER KD 500-1A MAPY by WITT-Gasetechnik is an electronic flow control system designed for modified atmospheres in food packaging and storage environments. It optimizes gas consumption and ensures product quality through precise oxygen level control.
Cost Reduction: The system can reduce gas consumption by up to 30% by automatically controlling the residual oxygen level to a predetermined set point. Non-destructive gas analysis ensures package quality and production economy.
Ease of Operation: Features include simple calibration, low maintenance, an easy-to-read display, integrated data logger, USB and Ethernet connections, and user-definable settings for different products.
High Process Reliability: The controller offers permanent O2 concentration monitoring, electronic sample gas control, and alarm signals for limit breaches. It operates independently of pressure fluctuations, packing speeds, and package sizes.
Maximum Hygiene: The device is housed in a splash-proof, robust stainless steel casing with a smooth, easy-to-clean surface.
Documentation and Options: Interfaces are available for documentation and remote transfer of settings and measurements. Optional features include GASCONTROL CENTER software, automatic calibration, bar code scanner, additional memory, and sample measurement via needle.
Technical Specifications: The controller is compatible with gases like N2, CO2, Ar, and their mixtures, excluding flammable gases. It uses a zirconia measuring cell for O2 with a range of 0-100%, repeatability of ±0.1%, and accuracy of ±0.3%. The device supports various gas connections and operates within a temperature range of 5-40°C.
Flow and Pressure: The document provides a detailed table of flow rates in relation to air outlet pressure and inlet pressure, with a maximum inlet pressure of 10 bar.
Approvals: The product is ISO 9001 and DIN EN ISO 22000 certified, CE-marked, and compliant with food-grade gas regulations.
See more

Catalog excerpts

WITT-Gasetechnik GmbH & Co KG, Salinger Feld 4-8, D-58454 Witten, Tel. +49 (0)2302-8901-0, witt@wittgas.comGAS FLOW CONTROLLER KD 500-1A MAPY 2025-1

GAS FLOW CONTROLLER KD 500-1A MAPY Electronic flow control system for modified atmospheres for flowwrap machines in the food industry and for room atmospheres e.g. for the storage of fruit and vegetables. Cost Reduction • saves up to 30% of gas consumption by automatic controlling the required residual oxygen level to a pre determined set point • the non-destructive gas analysis guarantees quality of the packages and economy of the production Easy Operation • simple calibration • easy to read display • integrated data logger • USB connection for file transfer • administration of product names • simple to operate via touch-screen • ethernet connection for network integration • measured data storage • user level with different access authorisation • user definable settings for each different product i.e. set point, alarm limits etc. High Process Reliability • electronic control of the sample gas to the sensor • lockable transparent door for protection of settings • alarm signals are given if the set limits are exceeded and a potential free contact operates to e.g. autostop your machine to avoid quality problems • independent of pressure fluctuations in the gas supply • independent of packing speeds (MAP) • independent of package sizes (MAP) Maximum Hygiene • splash-proof, robust stainless steel housing • smooth and easy to clean surface • Interfaces for the documentation and remote transfer of the settings and measured values • software GASCONTROL CENTER for recording of results (see separate data sheet) • fully automatic calibration • bar code scanner for product names or user selection • additional memory • sample measurement via needle - also with additional sensor Please identify the individual gases and control ranges of flow at the time of enquiring! WITT-Gasetechnik GmbH & Co KG, Salinger Feld 4-8, D-58454 Witten, Tel. +49 (0)2302-8901-0,

 Open the catalog to page 1
WITT-Gasetechnik GmbH & Co KG, Salinger Feld 4-8, D-58454 Witten, Tel. +49 (0)2302-8901-0, witt@wittgas.comGAS FLOW CONTROLLER KD 500-1A MAPY 2025-2

GAS FLOW CONTROLLER KD 500-1A MAPY Type N2, CO2, Ar or others as well as their mixtures; not for flammable gases! Measuring system zirconia measuring cell for O2 Measuring range Life time long lifetime Output (air) connection with central gas supply upstreamed mixer see table min. mixture output = 3% of the max. mixture output (see table) min. mixture output = 1/5 of the max. mixture output of mixer Temperatures (gas/environment) Gas connections inert gas analysis gas (lance) analysis gas (needle) purge air calibration gas G 1/2 with cone seat, hose nipple 11 mm PK 6/4 PK 6/4 PK 6/4 PK 6/4 (fully...