Catalog excerpts
GAS MIXER KM 10-2 FLEX Gas mixing systems for 2 defined gases, designed for variable processes with a mixing range from 5-92%. See other ranges on overleaf. Specially designed for applications with only low gas consumption. Ideally suitable as a portable desktop unit, e.g. for laboratory applications. Using a new mixing technology, no receiver is required. Capacity range up to approx. 28 Nl/min. For the exact pressure and flow capacity ratios, please see the technical data. Benefits ●● high mixing accuracy ●● avoids the need to stock multiple pre-mixes (cost saving) ●● does not require receiver (cost and space saving) ●● inlet gas filters protect the device against impurities ●● pneumatic operating principle, no electrical connections required ●● mixed gas production from 1 l/min to the max. flow ●● robust, compact design ●● minimal maintenance required Easy operation ●● a mixing valve with a control knob and %-scale provides infinitely variable mixture settings High process reliability ●● independent of pressure fluctuations in the gas supply ●● independent of withdrawal fluctuations (in permitted range) ●● fail safe design (unit shuts down on failure of either gas supply) ●● lockable to prevent tampering Options ●● alarm module NXT+: integrated inlet pressure monitoring with digital display for pressure (with analog pressure transmitters) plus optical alarm, adjustable alarm limits, obligation of acknowledgement, protection of alarms, interfaces for controlling external alarms etc. Other models, options and accessories available upon request. Please identify the individual gases at the time of enquiring! Flow KM 10-2 FLEX (in Nl/min) in relation to N2 min. mixed gas production 1 l/min outlet pressure in barg 0.5 min. inlet pressure in barg (max. 10 bar) WITT-Gasetechnik GmbH & Co KG, Salinger Feld 4-8, D-58
Open the catalog to page 1www.wittgas.com Type Gases Mixing range Pressure settings Inlet pressure differential between the gases KM 10-2 FLEX all technical gases (excluding toxic or corrosive gases, also no mixtures of fuel gases with air, O2 or N2O) 5 - 92% according to gas combination (see table) by selection of suitable mixing range the accuracy corresponds to ISO 14175 see table on the front page max. 3 bar Mixture output (N2) Setting accuracy Mixing range 1: < 5% Mixing range 2: 5 bis 20% Mixing range 3: > 20% see table on the front page (other gases on request) ± 0.5% absolute ± 10% of the nominal value ± 2%...
Open the catalog to page 2All WITT-Gasetechnik catalogs and technical brochures
-
Safety Relief Valves
5 Pages
-
MAP Gas Analysers
12 Pages
-
WITT Gas Mixers
16 Pages
-
Gas Safety Equipment
24 Pages
-
SAFETY GROUP 645/85-30
2 Pages
-
Non-return valves ULTRA
14 Pages
-
747 LE
4 Pages
-
737 LE
4 Pages
-
LEAK-MASTER PRO 2
2 Pages
-
OXYBABY 6.0
6 Pages
-
757 LE
6 Pages
-
767 LE
4 Pages
-
OXYBABY® M+
5 Pages
-
MAP Leak Detection
8 Pages
-
Witt catalogue 2021
84 Pages
-
INLINE-GAS ANALYSER MAPY VAC
2 Pages
-
GAS ANALYSER MAPY LE
2 Pages
-
GAS ANALYSER MAPY 4.0
2 Pages
-
BACK PURGING FILTER
1 Pages
-
WITT CALIBRATION MODULE
1 Pages
-
GASCONTROL WEBVISIO
1 Pages
-
THERMAL PROCESSING
1 Pages
-
GAS MIXER BM
2 Pages
-
Case Report
4 Pages
-
Practical examples
3 Pages
-
ADR 150
2 Pages
-
737LE-HD/S CO2
3 Pages
-
737 LE HD
2 Pages
-
386NPL
2 Pages
-
386NGA
1 Pages
-
150NF
1 Pages
-
150NA
2 Pages
-
150N
1 Pages
-
Lance Holder LK
1 Pages
-
Lance Holder SV
1 Pages
-
Security Handle Tube GHV
1 Pages
-
Shut-Off Valve
1 Pages
-
Ball Valves
2 Pages
-
Rig 722
1 Pages
-
WITTFIX
1 Pages
-
Inline Gas Analysis
2 Pages
-
Inlet Pressure Monitoring
2 Pages
-
gas_flow_controller_kd500_1a
2 Pages
-
software_gascontrol_webvisio
1 Pages
-
OXYBABY® Med
3 Pages
-
HYDROBABY
2 Pages
-
MIXED GAS RECEIVERS
1 Pages