GAS ANALYSER MAPY LE

GAS ANALYSER MAPY LE

GAS ANALYSER MAPY LE

Product catalog summary
Overview: The MAPY LE gas analyser by WITT-Gasetechnik is designed for monitoring gas concentrations, specifically O2, CO2, or a combination of both, in various industrial applications. It supports both continuous in-line analysis and intermittent sampling, making it suitable for applications like food packaging.
Key Features:
  • Minimal sample gas requirement for small volume analysis.
  • Fast measurement results with optional sampling.
  • User-friendly operation via a touch-screen interface.
  • High accuracy and reliable steady measurements with pressure compensation.
  • Simple sensor calibration and permanent monitoring of set limit values.
  • Alarm signals for exceeded limits with potential-free contact for machine auto-stop.
  • Stainless steel housing for hygiene and splash-proof design.
  • Data transfer via USB and Ethernet connectivity for network integration.
  • Internal audio alarm and data logging capabilities.
Options:
  • Fully automatic calibration and sample needle.
  • GASCONTROL CENTER-Software for result recording.
  • Separate table printer and line recorder for documentation.
  • Models for higher inlet pressures and various Ethernet cables.
  • Heater and thermostat for chemical measuring cell.
  • Web browser monitoring and email alerts on alarms.
Technical Specifications:
  • Gas Types: O2, CO2, or O2/CO2 (not suitable for flammable, corrosive, or toxic gases).
  • Temperature Range: 0 °C to +40 °C (32 °F to 104 °F).
  • Gas Connections: Permanent measuring lance and hose connection for PK 6/4.
  • Inlet Pressure: S-version max. 0.3 barg, P-version 1.5 to 10 barg.
  • Gas Consumption: Approx. 1 l/min, optimal calibration time 240 sec.
  • Alarm Contacts: 2 potential-free contacts for min. and max. settings.
  • Interfaces: RS 232, USB, RJ45 Ethernet, analog output 4-20 mA or 0-10 V.
  • Housing: Stainless steel, IP 54, weight approx. 15 kg.
  • Dimensions: 225 x 325 x 470 mm (8.86 x 12.80 x 18.50 inch).
  • Voltage: 230 V AC 50/60 Hz or 110 V AC 50/60 Hz.
  • Approvals: ISO 9001, ISO 22000, CE-marked, compliant with EMC 2014/30/EU, Low Voltage Directive 2014/35/EU, and Regulation (EC) No 1935/2004 for food-grade gases.
Measuring Systems:
  • O2 Sampling: Chemical measuring cell, range 0-100%, repeatability ± 0.2%, response time 6 sec, service life approx. 2 years in air.
  • O2 Continuous Analysis: Chemical measuring cell, range 0-100%, repeatability ± 0.2%, response time 10 sec, service life approx. 3 years in air.
  • Optional O2 Analysis: Zirconia measuring cell, range 0-100%, repeatability ± 0.1%, response time 4 sec, long lifetime.
  • CO2 Analysis: Infrared measuring cell, range 0-30% or 0-100%, repeatability ± 0.5%, response time 6 sec, long lifetime.
See more

Catalog excerpts

GAS ANALYSER MAPY LE-1

Analysing System for the monitoring of gas concentrations at a variety of industrial applications. For continuous analysis (in-line) and also intermittent sampling via a needle (option) e.g. from food packs. The analysis reduced to the essentials for a lean workflow. Available as a single or double analyser for oxygen and carbon dioxide. Benefits ●● minimum sample gas required for analysing of smallest volumes (e.g. food packaging) ●● separate table printer for instant documentation ●● fast measuring results of sampling (option) ●● model for higher inlet pressures ●● simple to operate via Touch-Screen ●● various Ethernet cable ●● reliable steady measuring results and high accuracy ●● heater and thermostat for chemical measuring cell ●● through pressure compensation ●● simple calibration of sensor ●● messaging via e-mail on alarm ●● line recorder for recording measuring results devel- ●● permanent monitoring of set limit values ●● alarm signals are given if the set limits are exceeded and a potential free contact operates to e.g. auto-stop your machine to avoid quality problems Equipment selection Analysis ●● easy to clean stainless steel housing for maximum results (see separate spec. sheet) Options ●● fully automatic calibration ●● GASCONTROL CENTER-Software for recording of ●● internal audio alarm ●● integration into networks by Ethernet connection Sampling (option) ●● data transfer via USB port Continuous Analysis hygiene, splash-proof without pump, with inlet pressure regulation with 2 chemical sensors for oxygen 3) gases to be specified All versions available with circonia measuring cell for O2. Please complete your type of equipme

 Open the catalog to page 1
GAS ANALYSER MAPY LE-2

GAS ANALYSER MAPY LE for O2, CO2 or O2/CO2 Measuring systems Measuring system Measuring range Response time Service life chemical measuring cell chemical measuring cell O2 for sampling and for continuous analysis zirconia measuring cell long lifetime O2 for sampling and for continuous analysis paramagnetic measuring cell adaptable please indicate dependent on measuring range long lifetime infrared measuring cell long lifetime O2, CO2 or O2/CO2 not for flammable, corrosive or toxic gases! Temperature (gas/environment) Gas connections Permanent measuring Sample measuring Calibration (full automatic)...

 Open the catalog to page 2

All WITT-Gasetechnik catalogs and technical brochures

  1. WITT Gas Mixers

    16  Pages

  2. GAS MIXER BM

    2  Pages

  3. HYDROBABY

    2  Pages

  4. 747 LE

    4  Pages

  5. 737 LE

    4  Pages

  6. OXYBABY 6.0

    6  Pages

  7. 757 LE

    6  Pages

  8. 767 LE

    4  Pages

  9. OXYBABY® M+

    5  Pages

  10. Case Report

    4  Pages

  11. ADR 150

    2  Pages

  12. 737 LE HD

    2  Pages

  13. 386NPL

    2  Pages

  14. 386NGA

    1  Page

  15. 150NF

    1  Page

  16. 150NA

    2  Pages

  17. 150N

    1  Page

  18. Ball Valves

    2  Pages

  19. Rig 722

    1  Page

  20. WITTFIX

    1  Page

Archived catalogs

  1. OXYBABY® Med

    3  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.