XRB Series

XRB Series

XRB Series

Product catalog summary
Introduction
Wisman’s XRB series of bipolar x-ray generators are designed for compatibility with various x-ray tubes from different manufacturers. They are ideal for OEM applications, offering an output voltage of up to 140kV and a maximum output power of 300 Watts. The series features a universal input, compact size, and three standard digital interfaces (RS232, USB2.0, RS485) for easy integration into x-ray analysis systems. The use of a digital signal processor (DSP) allows for flexible, stable, and precise control of the high voltage power supply. Multiple protection functions are included, such as overvoltage, overcurrent, and arc protection.
Typical Applications
The XRB series is suitable for a wide range of applications including x-ray fluorescence, x-ray diffraction, plating measurement, crystal inspection, diamond inspection, mineral analysis, plastics sorting, electrostatics applications, laser, capacitor charging, industrial applications, electronic component aging, insulation testing, electrophoresis, science, laboratory applications, ESD, sulfur detection, x-ray imaging, non-destructive testing, portable x-ray machines, RoHS detection, life sciences, and precious metal detection.
Specifications
The XRB series offers models with output voltages ranging from 80kV to 140kV and output power from 80W to 300W. The ripple is 0.1% p-p of the maximum rated output voltage, and stability is 0.01% per hour, 0.02% per 8 hours after a half-hour warm-up. The voltage/current monitor outputs 0~+10Vdc corresponding to 0 to full output, with an accuracy of ±1%. The temperature coefficient is ≤25ppm/°C. Operating temperature ranges from 0°C to +40°C, with storage temperatures from -40°C to +85°C. Humidity tolerance is 20% to 85% RH, non-condensing.
Safety and Protection
The XRB series includes safety interlocks and protection against overvoltage and short circuits. It supports local and remote programming, with options for RS232, RS485, and USB2.0 interfaces. OEM customization is available, and the units provide bipolar outputs in a single unit.
Dimensions and Weight
The dimensions for the 100kV model are 5.31 H x 7.47 W x 9.83 D inches (135mm x 190mm x 250mm) and for the 140kV model are 6.29 H x 8.25 W x 13.17 D inches (160mm x 210mm x 335mm). The weights are 8.05kg and 14.2kg respectively.
See more

Catalog excerpts

XRB Series-1

wisman High voltage power supply iiJl BIPOLAR OUTPUTS INASINGLE UNIT MODELS FROM 80kV~140kV,80W~ 300W OVER VOLTAGE &SHORT CIRCUIT PROTECTION LOCALAND REMOTE PROGRAMMING RS232,RS485 AND USB2.0 OPTIONAL SAFETY INTERLOCK OEM CUSTOMIZATIONAVAILABLE V_s Wisman's XRB series of bipolarx-ray generators aredesignedforallkinds ofx-raytubes from different manufacturers. ItisthebestchoiceofOEM applications, with outputvoltage 140kV(±70kV), max output power 300Watts. Wisman's XRB series x-ray generator adopts universal input, small package size and three standard digital interfaces which makes it easierto integrate the XRB series into yourx-ray analysis system. DSP (digital signal processor) makes highvoltage powersupply couldbe controlled more flexibly, stablyand exactly.Wisman's XRB series are with multiple protection functions like overvoltage, overcurrent and arc,incorporating local, remote and computer programming. RS232,USB2.0 and RS485 optional. TYPICAL APPLICATIONS X-Ray Fluorescence, X-Ray Diffraction, Plating Measurement, Crystal Inspection, Diamond Inspection, Mineral Analysis, Plastics Sorting.X-ray tubes,CapacitorCharging,Industrialapplications,Electronic component aging, Insulation Test, Electrophoresis, Electrostatics Applications, Laser, Science, Laboratory Applications.ESD, Sulfur-detector,X-ray imaging, Non-destructive testing, Portable X-ray machine, Rohs detector, Life Science, Precious metal detector, Industry. XRB SELECTION TABLE

 Open the catalog to page 1
XRB Series-2

XRB POWER INPUT/ CONNECTOR RS-232/RS-485 DIGITAL INTERFACE ° ANALOG INTERFACECONNECTOR ) 2019.2 Wisman High Voltage Power Supply Corp. All Rights Reserved 020219

 Open the catalog to page 2
XRB Series-3

Customer MountingHoles M4×8mm Max Depth

 Open the catalog to page 3

All Wisman High Voltage Power Supply catalogs and technical brochures

  1. MSE Series

    2  Pages

  2. MSD Series

    2  Pages

  3. MSC Series

    2  Pages

  4. MSB Series

    2  Pages

  5. MSA Series

    2  Pages

  6. WSM166

    1  Page

  7. V8 Series

    2  Pages

  8. V6 Series

    2  Pages

  9. RVD Series

    1  Page

  10. CA60 Series

    1  Page

  11. SEM Series

    3  Pages

  12. PRF Series

    3  Pages

  13. PRE Series

    3  Pages

  14. PRC Series

    3  Pages

  15. PRB Series

    3  Pages

  16. PRA Series

    3  Pages

  17. PMA Series

    3  Pages

  18. PF Series

    2  Pages

  19. HEM Series

    2  Pages

  20. FF Series

    2  Pages

  21. EMA Series

    3  Pages

  22. EM Series

    4  Pages

  23. EIB Series

    3  Pages

  24. ECD Series

    2  Pages

  25. ECA Series

    3  Pages

  26. EC Series

    3  Pages

  27. BA Series

    2  Pages

  28. B Series

    3  Pages

  29. 3DA Series

    3  Pages

  30. 3D Series

    3  Pages

  31. ZA Series

    2  Pages

  32. AMX Series

    2  Pages

  33. AMW Series

    3  Pages

  34. AMU Series

    2  Pages

  35. AMT Series

    2  Pages

  36. AMS Series

    2  Pages

  37. AMR Series

    2  Pages

  38. AMN Series

    2  Pages

  39. AML Series

    2  Pages

  40. AMK Series

    2  Pages

  41. AME Series

    2  Pages

  42. TC Series

    4  Pages

  43. TB Series

    4  Pages

  44. TA Series

    4  Pages

  45. SDL Series

    4  Pages

  46. SDG Series

    4  Pages

  47. SDF Series

    4  Pages

  48. S Series

    1  Page

  49. DR Series

    3  Pages

  50. DL Series

    3  Pages

  51. DH Series

    3  Pages

  52. DG Series

    5  Pages

  53. DF Series

    3  Pages

  54. DE Series

    3  Pages

  55. DC Series

    3  Pages

  56. DA Series

    2  Pages

  57. DEL Series

    2  Pages

  58. DEF Series

    3  Pages

  59. DED Series

    2  Pages

  60. DEC Series

    2  Pages

  61. DEA Series

    2  Pages

  62. XWA Series

    3  Pages

  63. XW Series

    4  Pages

  64. XRW Series

    3  Pages

  65. XRN Series

    3  Pages

  66. XRL Series

    3  Pages

  67. XRH Series

    3  Pages

  68. XRG Series

    3  Pages

  69. XRF Series

    3  Pages

  70. XRD Series

    6  Pages

  71. XRC Series

    3  Pages

  72. XRA Series

    5  Pages

  73. XNA Series

    3  Pages

  74. XN Series

    3  Pages

  75. XFN Series

    3  Pages

  76. XFL Series

    4  Pages

  77. XEL Series

    2  Pages

  78. XDF Series

    3  Pages

  79. XDB Series

    3  Pages

  80. XAA Series

    3  Pages

  81. XA Series

    2  Pages

  82. NDT Series

    4  Pages

  83. PMS Series

    3  Pages

  84. PMD Series

    3  Pages

  85. PMC Series

    3  Pages

  86. PMB Series

    3  Pages

  87. PM Series

    3  Pages

  88. MT Series

    3  Pages

  89. MRW Series

    3  Pages

  90. MRS Series

    2  Pages

  91. MRN Series

    3  Pages

  92. MRL Series

    3  Pages

  93. MRD Series

    5  Pages

  94. MRC Series

    3  Pages

  95. MRB Series

    3  Pages

  96. MRA Series

    4  Pages

  97. MN Series

    3  Pages

  98. MEF Series

    3  Pages

  99. MEB Series

    2  Pages

  100. ME Series

    3  Pages

  101. DNA Series

    2  Pages

  102. MUD Series

    2  Pages

  103. MUB Series

    2  Pages

  104. MBA Series

    2  Pages

  105. MB Series

    2  Pages

  106. MUC Series

    5  Pages

  107. MUA Series

    2  Pages

  108. MU Series

    3  Pages

  109. MMC Series

    2  Pages

  110. MMB Series

    2  Pages

  111. MMA Series

    2  Pages

  112. MM Series

    2  Pages

  113. MG Series

    2  Pages

  114. MFA Series

    2  Pages

  115. MF Series

    2  Pages

  116. MDC Series

    2  Pages

  117. MDA Series

    2  Pages

  118. MCP Series

    2  Pages

  119. MCE Series

    1  Page

  120. MCC Series

    2  Pages

  121. MCA Series

    2  Pages

  122. MC Series

    2  Pages

  123. MA Series

    2  Pages

  124. BP Series

    1  Page

  125. DEA

    2  Pages

  126. XA

    2  Pages

  127. PM

    3  Pages

  128. MB

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.