The document describes the DNA series of compact high voltage modules designed for applications requiring high stability, ultra-low ripple, and compact size. These modules are suitable for use in fields such as DNA sequencing, mass spectrometry, electron microscopy, electrophoresis, semiconductor testing, medical imaging (SPECT, PET scanners), and other scientific and industrial applications.

Applications

  • Life Science and Medical Industry (e.g., DNA sequencing, blood analysis, PET/SPECT scanners)
  • Scientific Experiments (e.g., electron beam ion beam, electron multiplying detectors)
  • Industrial Applications (e.g., semiconductor testing, capacitor charging, electrostatic discharge tests)

Specifications

The DNA series offers models with maximum output voltages of 20kV and 30kV, with output power ratings around 15W to 30W. Output polarity options include positive and negative. Key electrical parameters include:

  • Ripple: <= 0.01% peak-to-peak
  • Stability: less than 0.01% per hour and less than 0.02% over 8 hours after 30 minutes warm-up
  • Temperature coefficient: <= 25 ppm/°C
  • Input regulation and load regulation: approximately ±0.01%

Input voltage variations of ±10% result in minimal output changes, demonstrating high regulation performance.

Features

  • High stability and low ripple output
  • Compact size with dimensions approximately 43mm x 100mm x 205mm
  • Lightweight: 1 kg for 20kV models and 1.45 kg for 30kV models
  • Convection cooling suitable for operating temperatures from -20°C to +50°C and storage from -40°C to +85°C
  • Humidity tolerance: 20% to 85% non-condensing
  • Built-in protections: arcing, short circuit, and overload protection
  • Voltage and current programming via potentiometer or external reference voltage
  • Optional digital control interfaces: RS-232 and RS-485
  • OEM customization available

Options and Accessories

High voltage cable options include non-shielded and shielded cables with customizable lengths (e.g., 1 meter standard length with options for longer cables).

Control and Connectivity

The modules support both analog and digital control modes:

  • Analog control inputs allow 0-5 V DC signals to program output voltage and current from 0 to 100% of maximum.
  • Digital control via RS-232 or RS-485 interfaces enables remote programming and monitoring.

Mechanical Dimensions and Connectors

The mechanical layout includes an 8-pin input connector with clearly defined pins for input voltage, ground, programming inputs, and display outputs for voltage and current. The compact form factor facilitates integration into various systems.

Environmental and Operational Limits

  • Operating temperature range: -20°C to +50°C
  • Storage temperature range: -40°C to +85°C
  • Humidity: 20% to 85% relative humidity, non-condensing
  • Cooling method: convection cooling

Summary

The DNA series high voltage modules provide reliable, stable, and low-noise high voltage power suitable for precision scientific instruments and industrial equipment. Their compact size, comprehensive protection features, and flexible control options make them ideal for integration into advanced analytical and testing systems.

See more

Catalog excerpts

DNA Series-1

20KV-30KV 0.5mA MODULES wisman High voltage power supply iiJl Ol MODULES INTRODUCTION RS232, RS485DIGITALCONTROLOPTIONAL HIGH STABILITYAND RELIABILITY COMPACT, SIX-SIDES SHIELD, LOW RIPPLE VOLTAGE PROGRAMMING, CURRENT PROGRAMMINGAVAILABLE LOCALAND REMOTE CONTROL OEM CUSTOMIZATIONAVAILABLE <_> DNAisthecompacthigh voltage module with features ofhigh stability, ultra-low rippleandsmallsize.ANmodelscan provide potentiometer and external reference voltage programming and monitor. All units have in-built protection against arcing, short protection and overload protection. RS-232, RS485 digital control optional. APPLICATION DNASequencing, Mass Spectrometer, Micro-Channel,Electron Microscope ,Electrostatic DischargeTest( ESD),, UltrasonicTransducer, Electron Multiplying Detector ,Electrophoresis ,ElectronBeam, Ion Beam,ElectrostaticChuck High Voltage Bias , Pressure Test, Electrospinning , Capacitor Charging ,SemiconductorTest ,Aging ofElectronic Components , GasChromatography, BloodAnalysis,CathodeX-ray tube , SPECT Scanner, PET Scanner, Life Science, Medical Industry, Scientific Experiment, IndustrialApplication DNA SELECTION TABLE DNA SELECTION EXAMPLE SPECIFICATIONS "PARAMETER ) 2019.2 Wisman High Voltage Power Supply Corp. All Rights Reserved ______

 Open the catalog to page 1
DNA Series-2

Working Temperature Storage Temperature Convection cooling。 Humidity Dimensions 0~5Vdc corresponds to 0~100% output voltage 0~5Vdc=0~Max current 0~5Vdc=0~Max voltage 0~5Vdc corresponds to 0~100% output voltage 0~5Vdc corresponds to 0~100% output voltage DNA MECHANICAL DIMENSIONS UNIT: inch[mm] F 1.693[43.0]

 Open the catalog to page 2

All Wisman High Voltage Power Supply catalogs and technical brochures

  1. MSE Series

    2  Pages

  2. MSD Series

    2  Pages

  3. MSC Series

    2  Pages

  4. MSB Series

    2  Pages

  5. MSA Series

    2  Pages

  6. WSM166

    1  Page

  7. V8 Series

    2  Pages

  8. V6 Series

    2  Pages

  9. RVD Series

    1  Page

  10. CA60 Series

    1  Page

  11. SEM Series

    3  Pages

  12. PRF Series

    3  Pages

  13. PRE Series

    3  Pages

  14. PRC Series

    3  Pages

  15. PRB Series

    3  Pages

  16. PRA Series

    3  Pages

  17. PMA Series

    3  Pages

  18. PF Series

    2  Pages

  19. HEM Series

    2  Pages

  20. FF Series

    2  Pages

  21. EMA Series

    3  Pages

  22. EM Series

    4  Pages

  23. EIB Series

    3  Pages

  24. ECD Series

    2  Pages

  25. ECA Series

    3  Pages

  26. EC Series

    3  Pages

  27. BA Series

    2  Pages

  28. B Series

    3  Pages

  29. 3DA Series

    3  Pages

  30. 3D Series

    3  Pages

  31. ZA Series

    2  Pages

  32. AMX Series

    2  Pages

  33. AMW Series

    3  Pages

  34. AMU Series

    2  Pages

  35. AMT Series

    2  Pages

  36. AMS Series

    2  Pages

  37. AMR Series

    2  Pages

  38. AMN Series

    2  Pages

  39. AML Series

    2  Pages

  40. AMK Series

    2  Pages

  41. AME Series

    2  Pages

  42. TC Series

    4  Pages

  43. TB Series

    4  Pages

  44. TA Series

    4  Pages

  45. SDL Series

    4  Pages

  46. SDG Series

    4  Pages

  47. SDF Series

    4  Pages

  48. S Series

    1  Page

  49. DR Series

    3  Pages

  50. DL Series

    3  Pages

  51. DH Series

    3  Pages

  52. DG Series

    5  Pages

  53. DF Series

    3  Pages

  54. DE Series

    3  Pages

  55. DC Series

    3  Pages

  56. DA Series

    2  Pages

  57. DEL Series

    2  Pages

  58. DEF Series

    3  Pages

  59. DED Series

    2  Pages

  60. DEC Series

    2  Pages

  61. DEA Series

    2  Pages

  62. XWA Series

    3  Pages

  63. XW Series

    4  Pages

  64. XRW Series

    3  Pages

  65. XRN Series

    3  Pages

  66. XRL Series

    3  Pages

  67. XRH Series

    3  Pages

  68. XRG Series

    3  Pages

  69. XRF Series

    3  Pages

  70. XRD Series

    6  Pages

  71. XRC Series

    3  Pages

  72. XRB Series

    3  Pages

  73. XRA Series

    5  Pages

  74. XNA Series

    3  Pages

  75. XN Series

    3  Pages

  76. XFN Series

    3  Pages

  77. XFL Series

    4  Pages

  78. XEL Series

    2  Pages

  79. XDF Series

    3  Pages

  80. XDB Series

    3  Pages

  81. XAA Series

    3  Pages

  82. XA Series

    2  Pages

  83. NDT Series

    4  Pages

  84. PMS Series

    3  Pages

  85. PMD Series

    3  Pages

  86. PMC Series

    3  Pages

  87. PMB Series

    3  Pages

  88. PM Series

    3  Pages

  89. MT Series

    3  Pages

  90. MRW Series

    3  Pages

  91. MRS Series

    2  Pages

  92. MRN Series

    3  Pages

  93. MRL Series

    3  Pages

  94. MRD Series

    5  Pages

  95. MRC Series

    3  Pages

  96. MRB Series

    3  Pages

  97. MRA Series

    4  Pages

  98. MN Series

    3  Pages

  99. MEF Series

    3  Pages

  100. MEB Series

    2  Pages

  101. ME Series

    3  Pages

  102. MUD Series

    2  Pages

  103. MUB Series

    2  Pages

  104. MBA Series

    2  Pages

  105. MB Series

    2  Pages

  106. MUC Series

    5  Pages

  107. MUA Series

    2  Pages

  108. MU Series

    3  Pages

  109. MMC Series

    2  Pages

  110. MMB Series

    2  Pages

  111. MMA Series

    2  Pages

  112. MM Series

    2  Pages

  113. MG Series

    2  Pages

  114. MFA Series

    2  Pages

  115. MF Series

    2  Pages

  116. MDC Series

    2  Pages

  117. MDA Series

    2  Pages

  118. MCP Series

    2  Pages

  119. MCE Series

    1  Page

  120. MCC Series

    2  Pages

  121. MCA Series

    2  Pages

  122. MC Series

    2  Pages

  123. MA Series

    2  Pages

  124. BP Series

    1  Page

  125. DEA

    2  Pages

  126. XA

    2  Pages

  127. PM

    3  Pages

  128. MB

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.