Description & Features:
The document describes a universal transmitter designed for aggressive media, featuring high accuracy and stability. It is constructed with rugged stainless steel and a ceramic sensor, offering a range of pressures from in/Hg to 8,700 psi. The transmitter supports various mechanical and electrical connections, with an accuracy of ±0.25%. It is compliant with NEMA 4X and 6P, IP65, IP67, and IP68 standards, and is CE, CSA, and RoHS certified. The device is customizable and comes with a 1-year warranty.

Applications:
Suitable for environmental monitoring, machine tools, presses, test equipment, and other applications.

Specifications:
  • Output Signal: Standard 2-wire (4-20 mA) and optional 3-wire (0-20 mA, 0-10 V).
  • Accuracy: ±0.25% FSO.
  • Permissible Load: Current 2-wire: Rmax = [(Vs - Vs min) / 0.02] Ohm; Current 3-wire: Rmax = 500 Ohm; Voltage 3-wire: Rmin = 10 kOhm.
  • Influence Effects: Supply and load effects are 0.05% FSO.
  • Response Time: Less than 10 milliseconds.
  • Thermal Error: Less than ±0.2% FSO per 10K within a compensated range of -13°F to 185°F.
  • Permissible Temperatures: Medium: -40°F to 275°F; Electronics: -40°F to 185°F; Storage: -40°F to 212°F.
  • Protection: Short-circuit protection is permanent; reverse polarity protection prevents damage but disables function.
  • Electromagnetic Protection: Complies with EN 61326 for emission and immunity.
  • Stability: Vibration resistance of 10 g RMS and shock resistance of 100 g.
  • Housing and Parts: 304 SS housing, 316 Ti SS pressure port, ceramic diaphragm, and various seal options.
  • Weight: 140 g.
  • Current Consumption: 25 mA max for current, 7 mA max for voltage.
  • Operation Life: Over 100 million cycles.
  • Connecting Cables: Various cable types and lengths available, with specific requirements for gauge pressures.

Range and Pressure Codes:
The document lists various pressure ranges, overpressure, and burst pressure values, each associated with a specific code.

Order Codes:
The transmitter is identified by the code LIM for aggressive media applications.

Mechanical and Electrical Connections:
The document provides details on mechanical and electrical connections, including pin configurations for different systems and wiring diagrams.
See more

Catalog excerpts

LIM Aggressive Media Transmitter-1

Aggressive Media Transmitter Description & Features: • • • • • • • • • • • Universal transmitter with a high level of accuracy and stability Designed especially for aggressive media Rugged stainless steel construction with ceramic sensor Available ranges include in/Hg up to 8,700 psi Wide range of mechanical and electrical connections ±0.25% accuracy NEMA 4X and 6P / IP65, IP67 and IP68 CE, CSA and RoHS compliant Approved for outdoor use Customizable 1 year warranty Appropriate for environmental monitoring, machine tool and presses, test equipment and many other applications Order Codes Range Burst Pressure Permissible Load Current 2-wire: Rmax = [(Vs - Vs min) / 0.02] Ohm Current 3-wire: Rmax = 500 Ohm Voltage 3-wire: Rmin = 10 kOhm Influence Effects Supply: 0.05% FSO / 10 V Load: 0.05% FSO / kOhm Response Time Thermal Error Permissible Temperatures Short-circuit Protection Reverse Polarity Protection Electromagnetic Protection Output Signal Emission and immunity according to EN 61326 Pollution Degree Housing Pressure Port Wetted Parts Seals: PN < 1450 psi: FKM (Viton® standard, Kalrez® optional). PN > 1450 psi: NBR (Buna N). Others available. Diaphragm: Ceramic AI2O3 96% Current Consumption Operation Life Connecting Cables 4, electrical equipment for outdoor use Cable capacitance: Signal line/shield and signal line/signal line: 160 pF/m Cable inductance: Signal line/shield and signal line/signal line: 1 µH/m Kalrez® is a registered trademark of DuPont Performance Elastomers Viton® is a registered trademark of DuPont Performance Elastomers WINTERS INSTRUMENTS

 Open the catalog to page 1
LIM Aggressive Media Transmitter-2

Aggressive Media Transmitter Mechanical Connection Electrical Connection (up to 363 psi; nominal pressure abs. on request) 5 Different cable types/lengths 6 Standard: 2m PVC cable without ventilation tube. Optional: Cable with ventilation tube psi, cable with ventilation tube Wiring Diagram re-system Icurrent) 1/2" NPTF conduit fitting WINTERS INSTRUMENTS

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.