Group: Milton Roy
Catalog excerpts
ELECTRONIC PUMP CONTROLLER The WPC-9001 is an electronic control module designed to automate the speed control of Williams pneumatically operated metering pumps. The WPC-9001 interfaces with our pumps through the use of an electro-pneumatic solenoid valve. The solenoid valve is used in place of our Oscillamatic® controllers, where the speed is adjusted manually. Superior Pump Control The WPC-9001 is designed to receive a 4-20 mA input signal and generate a 24 VDC square wave output pulse. The pulses alternately energize and de-energize a 3-way solenoid valve, which in turn provides the air to operate the pump. WPC-9001-GP (Nema 4x) For General Purpose Locations WPC-9001-XP (Nema 7) For Hazardous Locations Annunciator light to indicate operation Pump selection reset button* Displays strokes per minute Selector/Annunciator for auto/manual mode Displays total strokes Auto to manual switching for loss of signal** Selector for dual pump system Manual mode stroke rate adjustment** Annunciator light for pump selection Weatherproof Enclosures (Nema 4x) for GP Automatic switching for ow condition* Explosion Proof (Nema 7) Weatherproof Enclosures available for XP * This feature applies to a two pump system. A ow switch is necessary to provide the no ow signal. ** During a manual mode the solenoid valve is operated by a repeat cycle timer. The rate can be adjusted through a potentiometer. FLOW ELEMENT & TRANSMITTER INPUT POWER* SIGNAL & POWER ELECTRICAL CONNECTION Standard 115 VAC, 48 watts (maximum) Standard 230 VAC, 48 watts (maximum) XP classication: N.E.C., Class 1, Div 1& 2, Group C&D ALARM OUTPUT SIGNALS • Loss of signal - N/O, N/C dry contact With adjustable delay from 0 to 5 minutes • Manual control mode - N/O, N/C dry contact proportion to the 4-20 mA input. The rate is eld adjustable. • Manual Mode - Field adjustable from 0 to 45 strokes per minute. INPUT SIGNAL • Auto Mode - The output is 0 to 45 strokes per minute in Pump Switching Mode - With a two pump system using the optional ow switch the unit selects the standby pump when no ow signal is transmitted. OUTPUT POWER • 24 VDC, 0.5 A square wave pulse Auto/Manual Switching Mode - With the loss of signal (signal drops below 3.5 mA for more than one minute) the unit automatically switches to the manual mode. SHIPPING WEIGHT: • * Specify power by adding the voltage to the base part number. Literature #39258 7/06
Open the catalog to page 1ELECTRONIC PUMP CONTROLLER MOUNTING DIMENSIONS WPC-9001-GP PULSE COUNTER MANUAL ADJUST POWER MANUAL ADJUST MANUAL CONTROL FRONT VIEW FRONT VIEW NOTE: Enclosure depth approximately 7.5 inches. NOTE: Enclosure depth approximately 5.5 inches. APPLICATIONS PRESSURE REGULATOR AIR/GAS SUPPLY 35 to 100 psig AUTO CONTROL MANUAL MANUAL ADJUST PUMP 4-20 mA Signal FLOW OR PH METER PROCESS FLUID CHEMICAL SUPPLY PART NUMBER FOR ORDERING ORDERING WPC-9001-GP-115 (Std. 115 VAC POWER) 201 Ivyland Road Ivyland, PA 18974-0577 USA • (215) 293-0415 • Toll Free in the USA (800) 235-3421 • Fax: (215) 293-0498...
Open the catalog to page 2All Williams Milton Roy catalogs and technical brochures
-
31049 MKVII PL RK
1 Pages
-
31025 5-2012 P125V V&X PL RK
2 Pages
-
30956 V Series
32 Pages
-
P2250 Parts List
1 Pages
-
P1500 Parts List 39288
2 Pages
-
PCV125-AL
1 Pages
-
APU-XP
1 Pages
-
W Series Pump IOM
25 Pages
-
MKXII Controller
2 Pages
-
Wilroy Brochure
6 Pages
-
V series Brochure
12 Pages
-
W-Series Brochure
8 Pages
-
Conversion Kit
4 Pages
-
Wilroy IOM
20 Pages
Archived catalogs
-
Williams V Dual Seal #30950
12 Pages