PCH420V-R6-HZ

PCH420V-R6-HZ

PCH420V-R6-HZ

Product catalog summary
Overview: The PCH420V series is a HART-enabled vibration transmitter designed for continuous asset monitoring. It features a 4-20 mA output with HART 7.0 protocol, allowing for remote configuration and diagnostics. The device supports single or multi-drop loop installations and is available in hazardous area certified models.
Key Features:
  • 4-20 mA + HART 7.0 output
  • Three user-configurable vibration bands
  • Remote configuration and diagnostics
  • Connector options: 2 pin MIL-C-5015 or 4 pin M12
  • Manufactured in an ISO 9001 approved facility
Certifications: The sensors are certified for use in hazardous areas, with models available for Class I, Div 2, Groups A, B, C, D, and Class I, Zone 2 environments. They meet the requirements for Ex nA nC IIC T4 Gc with a temperature range of -40°C to +105°C.
Specifications:
  • Full scale velocity output: 0.5 - 5.0 in/sec, peak
  • Frequency response: 10 Hz - 1 kHz (±10%), 3.0 Hz - 1.95 kHz (±3 dB)
  • Measurement accuracy: ±5% at 25°C, 100 Hz, 1 ips full scale
  • Power requirements: 12 - 30 VDC, 3.8 - 22 mA current draw
  • Temperature range: -40° to +105°C
  • Vibration limit: 500 g peak, Shock limit: 5,000 g peak
  • Sealing: Hermetic, Case material: 316L stainless steel
Installation and Connections: The device features a 1/4-28 tapped hole for mounting. The PCH420V-R6 model uses a 2 pin MIL-C-5015 connector, while the PCH420V-M12 model uses a 4 pin M12 connector. Recommended cabling and connectors are specified for each model.
Additional Information: Accessories include an SF6 mounting stud and calibration data. A Device Description (DD) file is available for download to facilitate integration with HART-enabled systems.
See more

Catalog excerpts

PCH420V-R6-HZ-1

The PCH420V series sensors are velocity transmitters with 4-20 mA outputs and the added capability of digital communications using HART protocol. The HART functionality allows user configuration of the sensors, enables multi-drop cable installations and allows the sensor to communicate directly with a HART-enabled DCS or PLC. The benefits are a sensor that can be configured by the user for a number of different full-scale ranges and filter settings, a reduction in the required cabling, and simple connection to existing plant infrastructure. Digital sensors allow improved connectivity into plant networks, improving efficiency and simplifying decision-making about machinery health. Note: Model numbers ending in -HZ are hazardous area certified sensors. Class I, Div 2 Groups A, B, C, D Class I, Zone 2 AEx/Ex nA nC IIC T4 Tamb: -40°C to +105°C The cable installed must be suitable for the installation temperature and the voltage of any intermingled circuits. • Connected cable must be of a type suitable for Zone 2 Hazardous Locations. • The connected cable and connector must provide a minimum ingress protection level of IP54, when assessed according to EN 60079-0 and EN 60079-15. Unused connector must be fitted with an appropriately rated blanking cover. • The connection must be made in a manner that cannot be separated without the use of a tool. • Where the installation requires that the Accelerometer enclosure be grounded, this is to be done using a metal mounting stud as described in document 13327-01, 13334-01, 13335-01 or 13336-01. • 4-20 mA + HART 7.0 output • Three user-configurable bands • Single or multi-drop loop installation • Hazardous area certified models available • Remote configuration and diagnostics • Connector options: 2 pin MIL-C-5015 (-R6 models) or M12 (-M12 models) • Continuous asset monitoring • Manufactured in an approved ISO 9001 facility Note: Due to continuous process improvement, specifications are subject to change without notice. This document is cleared for public release. Wilcoxon Sensing Technologies 8435 Progress Drive An Amphenol Company Fred^ck, MD 21701

 Open the catalog to page 1
PCH420V-R6-HZ-2

HART-enabled vibration transmitter PCH420V series Notes: 1 Maximum loop resistance (RL) can be calculated by: RL = HART communication requires min. 250Q resistance. Note: Due to continuous process improvement, specifications are subject to change without notice. This document is cleared for public release. Wilcoxon Sensing Technologies 8435 Progress Drive An Amphenol Company Fmd^ck, MD 21701

 Open the catalog to page 2

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.